3T Diffusion MRI Inter-Site Reproducibility Dataset for Cerebral Small Vessel Disease
This dataset provides multi-site diffusion MRI data from 10 patients diagnosed with the genetically defined small vessel disease CADASIL, scanned on two different 3 T Siemens MRI scanners (Magnetom Prisma and Magnetom Skyra) within 24 hours.
It enables evaluation of inter-scanner reproducibility of diffusion metrics in cerebral small vessel disease (SVD) and supports harmonization studies for multi-center neuroimaging trials.
The dataset was used in the publication:
Konieczny & Dewenter et al., Neurology, 2020 — https://doi.org/10.1212/WNL.0000000000011213
License
Creative Commons Attribution – NonCommercial 4.0 International (CC BY-NC 4.0)
Citation
Dewenter, A., Gesierich, B., & Duering, M. (2020).
3T diffusion MRI inter-site reproducibility dataset for cerebral small vessel disease [Data set]. Zenodo.
https://doi.org/10.5281/zenodo.16925507
Source
https://doi.org/10.5281/zenodo.16925507
Contact: marco.duering@med.uni-muenchen.de
Institution: Institute for Stroke and Dementia Research (ISD), LMU Munich, Germany
Associated publication: Neurology, 96(5), e698–e708 (2020)
Dataset Information
| Category | Details |
|---|---|
| Subjects | 10 patients with CADASIL (genetically confirmed or via skin biopsy) |
| Age (median [IQR]) | 55.5 years (13.3) |
| Sex | 5 female (50 %) |
| Hypertension / Hypercholesterolemia | 3 / 5 patients |
| WMH volume [% ICV] median (IQR) | 7.67 (2.62) |
| Lacune count median (IQR) | 3 (7.75) |
| Brain volume [% ICV] median (IQR) | 75.7 (7.03) |
| Scanner Types | Siemens 3 T Magnetom Prisma and Skyra |
| Scan Interval | < 24 hours |
| Protocol | Matched b-values, gradient directions, and resolution between scanners |
| BIDS-Compliance | Data organized per subject and session (/sub-XX/ses-prisma, /ses-skyra) |
| Preprocessing Tools | dcm2niix, MRtrix (dwidenoise & mrdegibbs), FSL (TOPUP & EDDY) |
| Anonymization | Fully de-identified and restricted to diffusion MRI only |
MRI Acquisition Protocol
| Parameter | Magnetom Skyra | Magnetom Prisma |
|---|---|---|
| Coil | 64-channel head/neck | 64-channel head/neck |
| TR (ms) | 3800 | 3200 |
| TE (ms) | 104.8 | 74 |
| Resolution (mm³) | 2×2×2 | 2×2×2 |
| b-values (s/mm²) | 1000 / 2000 | 1000 / 2000 |
| Directions (per b) | 30 / 60 | 30 / 60 |
| b = 0 images | 10 | 10 |
| Multi-band factor | 3 | 3 |
| Acceleration factor | 2 | 2 |
Both scanners were located in separate hospital buildings with independent infrastructure, establishing a true inter-site condition despite institutional proximity.
Data Structure and Preprocessing
The dataset follows the BIDS organization scheme:
/sub-01
/ses-prisma
/dwi_raw
/dwi_preprocessed
/ses-skyra
/dwi_raw
/dwi_preprocessed
- Raw data converted from DICOM via dcm2niix
- Preprocessed data includes denoising (MRtrix
dwidenoise), Gibbs correction (mrdegibbs), and motion/eddy distortion correction (FSLTOPUP,EDDY).
Purpose
This dataset serves as a benchmark for assessing inter-scanner reproducibility and harmonization of diffusion MRI measures across 3 T sites.
It is particularly relevant for researchers working on:
- Cross-site calibration of diffusion metrics in small vessel disease
- Methodological validation of preprocessing and harmonization pipelines
- Clinical reproducibility of DTI/DKI biomarkers in multicenter trials
Keywords
Diffusion MRI • DTI • CADASIL • Small Vessel Disease • Inter-site Reproducibility • Siemens Prisma • Siemens Skyra • BIDS • FSL • MRtrix • Neurology 2020