Identifies each pump of the drainage system, which acts as flow regulator.

Fields:

Column name Data type Description Example
id serial Id
node_id character varying(16) id of node
to_arc character varying(16) Id of arc that indicates flow direction
order_id smallint Id of flow regulator
flwreg_length double precision Length of flow regulator
curve_id character varying(16) Id of curve, defined inp_curve
status character varying(3) Status at start of simulation [ON, OFF]
startup numeric(12,4) Depth at inlet node when pump turns on
shutoff numeric(12,4) Depth at inlet node when pump turns off
nodarc_id varchar(20) Id of nodarc