-
Notifications
You must be signed in to change notification settings - Fork 18.7k
Closed
Labels
FrozenDueToAgeNeedsInvestigationSomeone must examine and confirm this is a valid issue and not a duplicate of an existing one.Someone must examine and confirm this is a valid issue and not a duplicate of an existing one.OS-Windows
Milestone
Description
What version of Go are you using (go version)?
$ go version go1.16.5 windows/amd64
Does this issue reproduce with the latest release?
Yes
What operating system and processor architecture are you using (go env)?
go env Output
$ go env set GO111MODULE= set GOARCH=amd64 set GOBIN= set GOCACHE=C:\Users\USER\AppData\Local\go-build set GOENV=C:\Users\USER\AppData\Roaming\go\env set GOEXE=.exe set GOFLAGS= set GOHOSTARCH=amd64 set GOHOSTOS=windows set GOINSECURE= set GOMODCACHE=C:\Users\USER\go\pkg\mod set GONOPROXY= set GONOSUMDB= set GOOS=windows set GOPATH=C:\Users\USER\go set GOPRIVATE= set GOPROXY=https://proxy.golang.org,direct set GOROOT=C:\Program Files\Go set GOSUMDB=sum.golang.org set GOTMPDIR= set GOTOOLDIR=C:\Program Files\Go\pkg\tool\windows_amd64 set GOVCS= set GOVERSION=go1.16.5 set GCCGO=gccgo set AR=ar set CC=gcc set CXX=g++ set CGO_ENABLED=1 set GOMOD=C:\Users\USER\source\repos\😶\go.mod set CGO_CFLAGS=-g -O2 set CGO_CPPFLAGS= set CGO_CXXFLAGS=-g -O2 set CGO_FFLAGS=-g -O2 set CGO_LDFLAGS=-g -O2 set PKG_CONFIG=pkg-config set GOGCCFLAGS=-m64 -mthreads -fno-caret-diagnostics -Qunused-arguments -fmessage-length=0 -fdebug-prefix-map=C:\Users\USER\AppData\Local\Temp\go-build132155260=/tmp/go-build -gno-record-gcc-switches
What did you do?
var ProgramData string = "ProgramData"
var FolderOfInterest string = "MyHiddenFolder"
var getsomedir, _ = os.UserHomeDir()
var PathToMyFolder string = filepath.Join(filepath.VolumeName(getsomedir), ProgramData, FolderOfInterest)
fmt.Println(PathToMyFolder)What did you expect to see?
C:\ProgramData\MyHiddenFolder
What did you see instead?
C:ProgramData\MyHiddenFolder
Description
I am writing a cross-platform app and on Windows, I store some data in the ProgramData folder. It turns out there is no rule that C: drive should be the root all the time... So to make the application get root volume dynamically,
- I get some path from env
- Extract Volume info
- Use filepath.Join to construct my complete path.
Issue
filepath.Join is missing \ after C:. That's literally its only purpose
Metadata
Metadata
Assignees
Labels
FrozenDueToAgeNeedsInvestigationSomeone must examine and confirm this is a valid issue and not a duplicate of an existing one.Someone must examine and confirm this is a valid issue and not a duplicate of an existing one.OS-Windows