Reverse engineering an EMOTIV EPOC EEG headset from the first USB byte upward, and building a working brain-computer interface on top of it, one experimentally verified step at a time.

No EMOTIV software, no licence, no subscription, no cloud account.

Status

Gates 1, 2 and 3 passed. Gate 4 half closed: stream decrypted, channels not yet mapped.

We are receiving live 32-byte packets at 128.03 Hz and decrypting them. The AES key for this headset is confirmed, the packet counter is 100% consistent, and the battery reads 97%. What remains is working out which bits form which electrode.

See docs/PROTOCOL.md for the protocol as measured, docs/ROADMAP.md for gate status, and docs/LAB_NOTES.md for the full experimental record.

The stream

Rate 128.03 reports/sec, 32 bytes each
Encryption AES-128-ECB, two independent 16-byte blocks per packet
Key <32-hex-key-redacted----------->, from serial characters 8 8 G M
Byte 0 counter, +1 modulo 128, 100.00% consistent
Battery one packet per 128, raw 246, about 97%
Link status feature report reads 21 ff 1f ff 1e 00 linked, a0 ff 1f ff 00 00 unlinked

The key was not copied from any project. Emokit, python-emotiv and CyKit contradict each other on the layout, so all five documented candidates were generated and tested against real packets. The winner scored 100.00%; the next best scored 2.36%.

The receiver

The receiver is a USB composite HID device:

VID / PID 0x21a1 / 0x0001
Strings Emotiv Systems Inc. / EPOC BCI
USB serial SN20REDACTED0000
Interface 0 HID, usage page 0xf0ff, 3-byte input report
Interface 1 HID, usage page 0xffff, 32-byte input report, 6-byte feature report
Access route HIDAPI. macOS owns both interfaces, so libusb cannot claim them

The 32-byte input report matches the classic EPOC packet size, and the serial format matches the classic-era SN + YYYYMMDD + 6-character pattern rather than the EPOC+ UD2016 pattern. Working position: this is a classic EPOC on a later dongle revision. Not yet proven.

Documents

Document What it is
docs/HARDWARE.md What this exact physical device is, every claim confidence-labelled
docs/RESEARCH.md Prior art: source-by-source, with the contradictions between projects called out
docs/ROADMAP.md The ten gates, what closes each one, and what would falsify it
docs/LAB_NOTES.md Every hardware run, including the failed ones
docs/PROTOCOL.md Our own protocol spec. Not written yet: it needs real packets first

Experiments

Directory Gate What it proves
experiments/01_detect_device/ 1 We can identify the receiver without EMOTIV software
experiments/02_raw_packets/ 2 Capture, diagnose and monitor raw HID reports

Setup

python3 -m venv .venv
.venv/bin/pip install hidapi

That is the whole dependency list.

Use

# Gate 1: identify the receiver
.venv/bin/python experiments/01_detect_device/detect.py

# Gate 2: capture raw reports
.venv/bin/python experiments/02_raw_packets/capture.py --count 100 --out captures/run
.venv/bin/python experiments/02_raw_packets/analyse.py captures/run.bin

# If the receiver is silent, work out why
.venv/bin/python experiments/02_raw_packets/diagnose.py
.venv/bin/python experiments/02_raw_packets/monitor.py --seconds 300 --out captures/mon

Principles

Passive until proven safe. Nothing in this repository writes to the headset or receiver. No output reports, no SET_FEATURE, no configuration, no firmware, no pairing changes, no fuzzing. Descriptor reads and GET_FEATURE reads only. The hardware stays in its working state.

Measurement before belief. Old repositories are treated as hypotheses to test, not as truth to copy. docs/RESEARCH.md documents a genuine contradiction between Emokit, python-emotiv and CyKit over the AES key layout, including projects using the same words for different things. We will resolve it against our own captured packets rather than picking a side.

Every claim is labelled. CONFIRMED, STRONGLY INFERRED, POSSIBLE, or UNKNOWN. Guesses are never presented as facts.

Negative results are results. A capture containing zero packets is stored and analysed as data, not discarded as a failure.

Layers stay separate.

USB/HID -> raw packet -> decoder -> EEG sample -> record/replay
        -> signal processing -> visualisation -> BCI

Replay from a capture file must be indistinguishable from live hardware to everything downstream, so that experiments remain repeatable without the headset.

Say what the signal actually is. Detecting a jaw clench or a blink through an EEG headset is EMG or EOG, not mind reading. Both are interesting. Only one of them is a brain-computer interface.