Notifications
You must be signed in to change notification settings - Fork 16
Analytic units
There are two types of analytic units: patterns and basic threshold.
- Navigate to
Analytics tab

-
Push
Add Analytic Unitbutton
-
Set the desired Analytic unit name and Choose a
Detector Type(pattern/threshold)
-
For
patternchoose needed pattern type (General, Peaks, Troughs, Jumps, Drops) and presscreate
-
For
Thresholdjust presscreate -
To delete any Analytic Unit press the
(delete) button
You can create more than 1 Analytic unit. Just repeat the provided steps.
-
Choose a condition from the dropdown menu, type in the needed value in the input box and click
Apply
-
Click the button with the
(chart) icon -
Hold down
Ctrlbutton on Windows orCmdon Mac and drag the cursor while holding downleft mouse buttonto label patterns on your data.

-
When you have finished labeling - click the button with the chart icon once more.
-
(Pending) status indicates that Hastic is downloading the dataset. -
(Learning) status indicates that Hastic is learning and detecting based on labeled segments
-
-
The patterns should become labeled in your graph soon

-
Segments labeled with chosen color and with thick black borders - are labeled by the user.
-
Segments without thick black border are detected by Hastic.
-
this icon means that the anomaly was marked by the server -
this icon means that the anomaly was marked by the user
-
-
Unlabelingsegments means the you simply remove specific segments from display, without triggering thelearningprocess for hastic. Tounlabelspecific segments from the graph you need to:- Enter
labelingmode (described above) - Pressing the
Ukey on your keyboard will enable
(unlabeling) mode - Hold down
Ctrlbutton on Windows orCmdon Mac and drag the cursor while holding downleft mouse buttonto mark segments for unlabeling. - Unlabeled segments should disappear
- Click the button with the
(chart) icon to apply changes and exit unlabeling mode.
- Enter
-
Deletingsegments means the you remove specific segments from display, and force Hastic to startlearningprocess. Hastic will take deleted segments into account and avoid detection of similar patterns. To delete specific segments you need to:-
Enter
labelingmode (described above) -
Pressing the
Dkey on your keyboard will enable
(deleting) mode -
Hold down
Ctrlbutton on Windows orCmdon Mac and drag the cursor while holding downleft mouse buttonto label segments for deletion. -
Deleted segments will change color to chosen
Deleted colorand will have thick black borders around them:
-
Click the button with the
(chart) icon to apply changes and exit deleting mode. -
Hastic will now start learning again, based on updated segments list.
-
Each analytic unit has Inspect mode. It shows detection progress on the current timerange.
Inspect button becomes available after learning. Metric parts become underlined with detection statuses when analytic unit is in Inspect mode.

Note: you can
Inspectonly one analytic unit at a time.