New Features

  • proliant com storage list/storage describe <server name>: new fleet-wide and per-server RAID controller / direct-attached disk inventory for COM-managed servers, matching proliant ilo storage and proliant oneview storage. Reads COM's own cached /servers/{id}/inventory mirror of each server's Redfish Storage data — no direct iLO network reachability or per-server iLO credentials required, only an authenticated proliant com login session.
  • proliant com servers describe / proliant oneview servers describe: both now embed the same per-controller / per-disk Storage section (RAID Controller vs. Direct/HBA classification) that proliant ilo servers describe already showed — no need to run a separate storage describe to see disk detail. Best-effort: silently omitted if storage inventory isn't available for that server.

Bug Fixes

  • storage list (all of ilo/oneview/com): fixed a N x ? phantom disk group showing up for empty/unpopulated drive bays — some Redfish Storage resources report a stub Drive entry (Status.State: "Absent") for a bay with nothing installed; these are now filtered out before counting/classifying disks.
  • storage describe (all of ilo/oneview/com): the per-disk Capacity column now shows decimal GB (matching storage list) instead of GiB.

Enhancements

  • storage list columns renamed: Disks Behind Controller → RAID Attached, Disks Direct-Connected → Direct Attached, matching standard industry terminology (DAS = Direct-Attached Storage). Disk group formatting simplified from (N x SIZE TYPE) to plain N x SIZE TYPE.
  • storage list (all of ilo/oneview/com): when a server has more than one RAID/HBA controller, the Storage Controller and RAID Attached columns now line up one controller per row, so it's clear which disks sit behind which controller instead of merging them into one combined group.
  • storage list: when a controller (or the direct-attached group) has multiple distinct disk sizes/types (e.g. an MR408i-o with 4x3201GB + 3x1920GB + 1x1600GB NVMe), each size/type now gets its own line instead of one long comma-joined line, so wide fleets stay readable in a narrow column.
  • storage list output is now unified across ilo/oneview/com: all three now render the same plain fixed-width table (no title line, no box borders) that ilo storage list originally used — oneview/com previously used a bordered Rich table.