HydraFW 1 wire guide

Benjamin Vernoux edited this page Oct 1, 2018 · 5 revisions

HydraFW Bus 1-wire

Bus: 1-wire
Connections: One pin and ground
Output types: open drain/open collector
Pull-up resistors: required for open drain output mode (2K – 10K).
Pull-up/down resistors Integrated in MCU: Between 30 to 50K (Typical 40K).
Maximum voltage: 5.5volts (5volt safe)

This guide is updated towards firmware release HydraFW v0.9 Beta

Protocol configuration syntax description:

  • show Show 1-wire parameters or show pins Show pins used in this mode

  • pull with parameter up or down or floating to choose internal MCU pull up/down or no pull/external

  • msb-first or lsb-first to send/receive respectively MSB first or LSB first.

  • scan Discovers device on the 1-wire bus and displays their addresses.

  • exit to exit 1-wire mode

Note default value: 
    > 1-wire 
    Device: onewire1
    GPIO resistor: floating
    Bit order: LSB first

Configuration options:

Hardware Informations:

onewire1> show pins 
PIN: PB11

Protocol configuration example:

Configuration of onewire1 wit internal pullup :

> 1-wire 
Device: onewire1
GPIO resistor: floating
Bit order: LSB first
onewire1> pull up
onewire1> show 
Device: onewire1
GPIO resistor: pull-up
Bit order: LSB first
onewire1> 

Protocol interaction syntax description:

trigger configures the trigger mode

r or read Read one byte. (r:1…255 for bulk reads)

hd Read one byte. (hd:1…4294967295 for bulk reads). Displays a hexdump of the result (See Hexdump guide)

w or write Followed by values to write byte(s). (w:1…255 for bulk writes)

0 Write this Octal value. Format is prefixed by a 0 (values from 000 to 077)

0b Write this binary value. Format is 0b00000000 for a byte, but partial bytes are also fine: 0b1001.

0x Write this HEX value. Format is 0x01. Partial bytes are fine: 0xA. A-F can be lower-case or capital letters.

0-255 Write this decimal value. Any number not preceded by 0x or 0b is interpreted as a decimal value.

" Write an ASCII-encoded string

Write support optional repeat : (eg.: 10:1…255 for repeated write of same value 10 in this example)

space Value delimiter. Use a space to separate numbers/commands. Any combination is fine, delimiter is required between each number/command, example: [ 0x1 0xff 0 10 0b11 077 ]

& Delay 1uS. (&:1…1000000 for multiple delays)

% Delay 1mS. (%:1…1000000 for multiple delays)

~ Write a random byte. (~:10 repeats the same random byte 10 times)

Protocol interaction example usage onewire1 write/read:

onewire1> scan 
Discovered devices : 28 FF 10 2E A6 15 01 3B 
onewire1> [ 0x33 hd:8
WRITE: 0x33
28 FF 10 2E A6 15 01 3B                           |  (......; 

Additional informations about 1-wire

For more information about the 1-wire protocol, see : https://www.maximintegrated.com/en/app-notes/index.mvp/id/1796