Skip to content

Failure modes

github-actions[bot] edited this page Oct 20, 2026 · 1 revision

Failure modes

Every failure mode can be detected at increasing levels of sophistication, so vendors can show anything from a threshold to a digital twin on the same data. Real alarm and trip values are OEM-specific; the ones here are plausible demo values.

Detection ladder

Level Method Example here
L1 Fixed threshold PLC pad alarm at 75 °C
L2 Rate of change, trend °C per hour on a pad; pump starts per hour
L3 Model residual: expected vs. measured Pad temperature vs. MW, cooling water temperature and flow, oil temperature
L4 Spectral analysis on the waveforms FFT, orbit, envelope, order tracking
L5 Multivariate ML or a digital twin Cumulative erosion, fatigue, remaining useful life

The 15 failure modes

# Failure mode Signature in the simulation Topics (CH tree unless noted) Detection Scenario
1 Guide/thrust bearing degradation One TGB pad creeps, then accelerates; pad-to-pad spread grows; late on, TGB 1X grows Bearings/TGB/PadTemp01..04, OilTemp L1 75/85 °C; L2 °C/h; L3 pad temp vs. MW, cooling water and oil temp (flagship demo) A
2 Cooling water loss / cooler fouling Flow drops and all temperatures on it rise together; or flows normal, oil hotter, cooler outlet colder Cooling/*, all pads and oils, Generator/StatorTemp*; customer CoolingWaterFlow L1 low flow; L3 heat-transfer trend B; cooler_fouling
3 Oil contamination / water ingress TGB oil level rises slowly, temperature creeps Bearings/TGB/OilLevel, OilTemp L1/L2 level trend oil_water_ingress
4 Mechanical unbalance 1X up, stable phase, grows with speed² Shaft waveforms + keyphasorIdx, Overall_um_pp L1 overall (alert 140 µm pp); L4 1X vector, orbit F
5 Misalignment / bearing clearance 1X + strong 2X, elliptical orbit Shaft waveforms L4 orbit, 2X amplitude misalignment
6 Hydraulic unbalance 1X rises with gate opening, not with speed Shaft waveforms + Context/GatePosition_pct L3/L4 vibration vs. operating point hydraulic_unbalance
7 Draft-tube vortex rope Pressure pulsation at 0.28 × 5 Hz = 1.4 Hz, sub-synchronous shaft vibration, MW swings (customer tree) Vibration/DraftTube/Pressure/Waveform, TGB shaft waveforms, Vel_mm_s_rms L4 dominant frequency; L3 time-in-rough-zone counter C (and every load ramp through the zone)
8 Cavitation erosion High-frequency bursts, modulated at blade pass, at high gate, off-design head and low tailwater Vibration/Headcover/Accel/Waveform, Vel_mm_s_rms, Context/TailwaterLevel_m L4 band energy / envelope; L5 cumulative erosion H
9 Runner crack / blade fatigue Blade-pass harmonic (130 Hz) and ±1X sidebands grow Accelerometer, TGB shaft waveforms L4 order tracking; L5 fatigue twin runner_crack
10 Wicket-gate shear pin failure Discrete status, vibration step at constant MW Turbine/ShearPinStatus, WicketGateBreakawayAlarm, vibration L1 event; L3 step detection E
11 HPU pump wear / internal leakage Pump starts per hour rise, faster pressure decay, longer runs Governor/HPU/Pump1Running, Pump2Running, PumpStartsPerHour, AccumulatorPressure L2 duty trend; L3 leak rate from dP/dt D
12 Servomotor seal / oil leak Sump level drops, servo B lags the setpoint Governor/HPU/SumpLevel, ServoPositionA/B, GateSetpoint L2 trend; L3 position error servo_seal_leak
13 Shaft-seal wear Seal water flow and sump pump starts rise Turbine/ShaftSealWaterFlow, HeadcoverSumpPumpStarts, HeadcoverPressure L2 counter trends shaft_seal_wear
14 Generator air-gap anomaly Minimum air gap shrinking Generator/AirGapMin_mm L1 minimum (10.5 mm); L2 trend air_gap
15 Sensor failure (teaching case) Drift, flatline or spike on one RTD while its neighbours are normal; quality stays GOOD Any pad temperature L1 range/flatline; L3 cross-sensor consistency G

Normal values (demo, ~37 MW per unit)

Signal Typical
Thrust pads / oil bath ~64–68 / ~51 °C
Guide bearing pads ~55–65 °C
Cooling water inlet 14 °C ± 0.8 (daily)
Cooling flows TB / GB / air coolers 8 / 12 / 60 L/s
Accumulator pressure 58–63 bar (lead pump on at 58, off at 63; lag pump on at 54)
Pump starts ~6–7 per hour
Shaft displacement overall ~40–60 µm pp
Headcover velocity ~1 mm/s RMS
Stator temperatures ~65 °C
Minimum air gap ~11.6 mm
Draft-tube pressure ~0.6 bar (gauge)

CH PLC alarm limits

The PLC's own limit checks, published on Events/Alarm (ids in brackets, <b> a bearing, <n> a pad or RTD number, <ax> X or Y). They clear with a 1 % deadband.

Alarm Limit Severity
Pad temperature (<b>_PAD<n>_H, _HH) > 75 / > 85 °C WARNING / CRITICAL
Oil temperature (<b>_OIL_H) > 65 °C WARNING
Cooling water flow (COOLING_TB_L, _GB_L, _AIRCOOLERS_L) < 70 % of nominal, while running WARNING
Accumulator pressure (HPU_PRESSURE_L) < 52 bar WARNING
Pump starts (HPU_STARTS_H) > 15 per hour WARNING
Filter ΔP (HPU_FILTER_H) > 2.5 bar WARNING
Sump level (HPU_SUMP_L) < 55 % WARNING
Shear pin (SHEAR_PIN_BROKEN) BROKEN CRITICAL
Headcover vibration (HEADCOVER_VIB_H) > 4.5 mm/s RMS, while running WARNING
Shaft vibration (VIB_<b>_<ax>_ALERT, _DANGER) > 140 / > 220 µm pp, while running (in the spirit of ISO 20816-5 zones B/C and C/D) WARNING / CRITICAL
Air gap (AIRGAP_L) < 10.5 mm, while running WARNING
Stator temperature (STATOR_<n>_H) > 120 °C WARNING

The customer's unit protection has its own, higher limits on its own sensors: see Copper Canyon Dam.

Sources: vibration limits per ISO 20816-5; hydro condition monitoring guidance in ISO 19283; governor values from Reclamation FIST 2-3.

Clone this wiki locally