Repository navigation
Failure modes
github-actions[bot] edited this page Oct 20, 2026
·
1 revision
Every failure mode can be detected at increasing levels of sophistication, so vendors can show anything from a threshold to a digital twin on the same data. Real alarm and trip values are OEM-specific; the ones here are plausible demo values.
| Level | Method | Example here |
|---|---|---|
| L1 | Fixed threshold | PLC pad alarm at 75 °C |
| L2 | Rate of change, trend | °C per hour on a pad; pump starts per hour |
| L3 | Model residual: expected vs. measured | Pad temperature vs. MW, cooling water temperature and flow, oil temperature |
| L4 | Spectral analysis on the waveforms | FFT, orbit, envelope, order tracking |
| L5 | Multivariate ML or a digital twin | Cumulative erosion, fatigue, remaining useful life |
| # | Failure mode | Signature in the simulation | Topics (CH tree unless noted) | Detection | Scenario |
|---|---|---|---|---|---|
| 1 | Guide/thrust bearing degradation | One TGB pad creeps, then accelerates; pad-to-pad spread grows; late on, TGB 1X grows |
Bearings/TGB/PadTemp01..04, OilTemp
|
L1 75/85 °C; L2 °C/h; L3 pad temp vs. MW, cooling water and oil temp (flagship demo) | A |
| 2 | Cooling water loss / cooler fouling | Flow drops and all temperatures on it rise together; or flows normal, oil hotter, cooler outlet colder |
Cooling/*, all pads and oils, Generator/StatorTemp*; customer CoolingWaterFlow
|
L1 low flow; L3 heat-transfer trend | B; cooler_fouling
|
| 3 | Oil contamination / water ingress | TGB oil level rises slowly, temperature creeps |
Bearings/TGB/OilLevel, OilTemp
|
L1/L2 level trend | oil_water_ingress |
| 4 | Mechanical unbalance | 1X up, stable phase, grows with speed² | Shaft waveforms + keyphasorIdx, Overall_um_pp
|
L1 overall (alert 140 µm pp); L4 1X vector, orbit | F |
| 5 | Misalignment / bearing clearance | 1X + strong 2X, elliptical orbit | Shaft waveforms | L4 orbit, 2X amplitude | misalignment |
| 6 | Hydraulic unbalance | 1X rises with gate opening, not with speed | Shaft waveforms + Context/GatePosition_pct
|
L3/L4 vibration vs. operating point | hydraulic_unbalance |
| 7 | Draft-tube vortex rope | Pressure pulsation at 0.28 × 5 Hz = 1.4 Hz, sub-synchronous shaft vibration, MW swings (customer tree) |
Vibration/DraftTube/Pressure/Waveform, TGB shaft waveforms, Vel_mm_s_rms
|
L4 dominant frequency; L3 time-in-rough-zone counter | C (and every load ramp through the zone) |
| 8 | Cavitation erosion | High-frequency bursts, modulated at blade pass, at high gate, off-design head and low tailwater |
Vibration/Headcover/Accel/Waveform, Vel_mm_s_rms, Context/TailwaterLevel_m
|
L4 band energy / envelope; L5 cumulative erosion | H |
| 9 | Runner crack / blade fatigue | Blade-pass harmonic (130 Hz) and ±1X sidebands grow | Accelerometer, TGB shaft waveforms | L4 order tracking; L5 fatigue twin | runner_crack |
| 10 | Wicket-gate shear pin failure | Discrete status, vibration step at constant MW |
Turbine/ShearPinStatus, WicketGateBreakawayAlarm, vibration |
L1 event; L3 step detection | E |
| 11 | HPU pump wear / internal leakage | Pump starts per hour rise, faster pressure decay, longer runs |
Governor/HPU/Pump1Running, Pump2Running, PumpStartsPerHour, AccumulatorPressure
|
L2 duty trend; L3 leak rate from dP/dt | D |
| 12 | Servomotor seal / oil leak | Sump level drops, servo B lags the setpoint |
Governor/HPU/SumpLevel, ServoPositionA/B, GateSetpoint
|
L2 trend; L3 position error | servo_seal_leak |
| 13 | Shaft-seal wear | Seal water flow and sump pump starts rise |
Turbine/ShaftSealWaterFlow, HeadcoverSumpPumpStarts, HeadcoverPressure
|
L2 counter trends | shaft_seal_wear |
| 14 | Generator air-gap anomaly | Minimum air gap shrinking | Generator/AirGapMin_mm |
L1 minimum (10.5 mm); L2 trend | air_gap |
| 15 | Sensor failure (teaching case) | Drift, flatline or spike on one RTD while its neighbours are normal; quality stays GOOD | Any pad temperature | L1 range/flatline; L3 cross-sensor consistency | G |
| Signal | Typical |
|---|---|
| Thrust pads / oil bath | ~64–68 / ~51 °C |
| Guide bearing pads | ~55–65 °C |
| Cooling water inlet | 14 °C ± 0.8 (daily) |
| Cooling flows TB / GB / air coolers | 8 / 12 / 60 L/s |
| Accumulator pressure | 58–63 bar (lead pump on at 58, off at 63; lag pump on at 54) |
| Pump starts | ~6–7 per hour |
| Shaft displacement overall | ~40–60 µm pp |
| Headcover velocity | ~1 mm/s RMS |
| Stator temperatures | ~65 °C |
| Minimum air gap | ~11.6 mm |
| Draft-tube pressure | ~0.6 bar (gauge) |
The PLC's own limit checks, published on Events/Alarm (ids in brackets, <b> a bearing, <n>
a pad or RTD number, <ax> X or Y). They clear with a 1 % deadband.
| Alarm | Limit | Severity |
|---|---|---|
Pad temperature (<b>_PAD<n>_H, _HH) |
> 75 / > 85 °C | WARNING / CRITICAL |
Oil temperature (<b>_OIL_H) |
> 65 °C | WARNING |
Cooling water flow (COOLING_TB_L, _GB_L, _AIRCOOLERS_L) |
< 70 % of nominal, while running | WARNING |
Accumulator pressure (HPU_PRESSURE_L) |
< 52 bar | WARNING |
Pump starts (HPU_STARTS_H) |
> 15 per hour | WARNING |
Filter ΔP (HPU_FILTER_H) |
> 2.5 bar | WARNING |
Sump level (HPU_SUMP_L) |
< 55 % | WARNING |
Shear pin (SHEAR_PIN_BROKEN) |
BROKEN |
CRITICAL |
Headcover vibration (HEADCOVER_VIB_H) |
> 4.5 mm/s RMS, while running | WARNING |
Shaft vibration (VIB_<b>_<ax>_ALERT, _DANGER) |
> 140 / > 220 µm pp, while running (in the spirit of ISO 20816-5 zones B/C and C/D) | WARNING / CRITICAL |
Air gap (AIRGAP_L) |
< 10.5 mm, while running | WARNING |
Stator temperature (STATOR_<n>_H) |
> 120 °C | WARNING |
The customer's unit protection has its own, higher limits on its own sensors: see Copper Canyon Dam.
Sources: vibration limits per ISO 20816-5; hydro condition monitoring guidance in ISO 19283; governor values from Reclamation FIST 2-3.
Start
Understand
- Copper Canyon Dam
- Architecture
- Customer data vs. machine-builder data
- Example Unified Namespace
- Failure modes
- RCA demo walkthrough
- RCA with Claude: a guide for engineers
Use
- Dam SCADA
- CH asset viewer
- Instructor station
- Node-RED and MQTT Explorer
- Namespace
- Interface reference
- Configuration
For vendors
Contribute