Getting started

Easiest way

Open Claude Code in the repository folder and run this prompt:

read the CLAUDE.md file and README.md file and set up the environment

Prerequisites

  • Docker Desktop (or Docker Engine + Compose v2)
  • Free host ports. They are chosen so Haltenberg and Sweet Harmony can run at the same time:
Service Port
Hub + dam SCADA 8120
Instructor station 8121
CH asset viewer 8122
Mosquitto (MQTT) 1884
Node-RED 1881
MQTT Explorer 4001

Ports taken? Set other ones in a .env file, see Configuration.

Start

git clone https://github.com/itotinsider/cromley-hydraulics-uns.git
cd cromley-hydraulics-uns
docker compose up -d --build

Then open the hub at http://localhost:8120. The dam starts at steady state: all three units generating, the plant at its 110 MW setpoint. No start-up procedure is needed.

What Where
Hub (all systems) http://localhost:8120
Dam SCADA http://localhost:8120/scada
Unit detail (e.g. Unit 1) http://localhost:8120/scada#unit/Unit1
Instructor station (fault scenarios) http://localhost:8121
CH asset viewer http://localhost:8122
MQTT broker mqtt://localhost:1884 (anonymous, no TLS)
MQTT Explorer http://localhost:4001 (click Connect on "Copper Canyon Dam")
Node-RED http://localhost:1881
Bearing pads, 1-min averages (CSV, written by Node-RED) exports/ch_bearings_1min.csv

Dam SCADA overview

A first tour (15 minutes)

New to dams? Read Dams and turbines in brief first.

  1. Open the dam SCADA from the hub. The overview shows the reservoir and tailwater level, the head, the total MW against the grid operator's setpoint, the river flow and the state of Units 1–3, the spillway and the bottom outlet.
  2. Open Unit 1: the water path from the inlet valve to the draft tube, gate position, MW, speed, and the customer's own bearing temperatures and cooling water flow.
  3. Open MQTT Explorer and connect. You see two trees on one broker: v1.0/DRWPA/CopperCanyon (the customer) and v1.0/CH/Fleet/DRWPA/CopperCanyon/<serial> (the machine builder). Compare Powerhouse/Unit1/TurbineGuideBearingTemp with CH-FR-1987-0042/Bearings/TGB/PadTemp01 … PadTemp04.
  4. Open the CH asset viewer at http://localhost:8122. Pick CH-FR-1989-0051 (Unit 3): the nameplate, the process tree with quality and seq, and a raw shaft waveform with its orbit.
  5. Open the instructor station at http://localhost:8121 and start F. Mechanical unbalance after maintenance on Unit 3.
  6. In the CH viewer, watch Vibration/UGB/ShaftX/Overall_um_pp jump from ~45 to ~150 µm pp and the PLC raise VIB_UGB_X_ALERT. The next waveform block (every 30 s, or right away with the alarm trigger) shows a bigger, phase-shifted orbit. The dam SCADA sees nothing: the customer has no vibration probes.
  7. Try the opposite: start B. Cooling-water strainer blockage on Unit 2. Now the customer notices first: the SCADA raises Unit2 Cooling water flow low within about 4 minutes, then the thrust bearing temperature alarms (SCADA limit 75 °C after ~12 minutes, the unit controller's 80 °C after ~18). Left alone, the unit trips on bearing temperature (90 °C).
  8. Recover: on the instructor station press Stop on each scenario ("repair"). If a unit tripped, reset it on the SCADA unit display once it is at standstill, then start it again.

Stop / reset

docker compose down                 # stop
rm data/ch_plc_counters.json        # reset the turbine counters (starts, run hours, trips)
rm mosquitto/data/mosquitto.db      # forget retained messages (last values, nameplates, status)

The dam itself always restarts at its design operating point. The SCADA and the CH viewer keep trends in memory only, so a restart starts with empty trends.

After any code or web change: docker compose up -d --build (files are copied into the images).