Stable release. Quick Charge local control on all three connection paths, multi-step firmware updates, and large battery-bank stability — consolidating the 3.5.0 beta line. Requires pylxpweb 0.9.38 (installed automatically).
New in 3.5.0
- Quick Charge on all three connection paths (#366) — Local/Hybrid start a quick charge over Modbus with the requested duration (paired register 233/234 frame, live-validated on FlexBOSS21), not just via the cloud.
- Multi-step firmware updates run to completion (#353) — multi-component devices (6000XP) converge instead of stopping on a partial version; failures are surfaced.
- Large battery banks stay live at solar peak (#367) — the corruption canary scales with battery count.
- Quieter GridBOSS dongle logs (read-failure ERROR → DEBUG).
- Two post-beta.3 fixes from a Codex re-review of the DRY consolidation: history-import recovery snapshot data-loss on a narrow-range retry, and a Quick Charge Duration stale-preference display after a live write.
Recap from the 3.4.0 cycle
Schedule time entities for seven families (AC Charge, AC First, Forced Charge, Forced Discharge, Peak Shaving, Generator, Off-Grid), Grid Peak Shaving controls, an Operating State sensor + Off-Grid binary sensor, off-grid AC-charge SOC controls, reliable >4-battery banks, and Hybrid-mode stability.