v0.9.36b22
Pre-release
Pre-release
Added
- AC First schedule support (eg4_web_monitor#295, #201):
ScheduleType.AC_FIRST+ScheduleConfig("HOLD_AC_FIRST", 152)— the off-grid (SNA/XP) grid-passthrough schedule at holding registers 152-157, withset/get_ac_first_schedulewrappers symmetric with the other schedule types. Cloud parameter names (HOLD_AC_FIRST_{START|END}_{HOUR|MINUTE}+_1/_2window suffixes) verified against the EG4 portal's SNA working-mode page; registers pinned by the SNA12K-US live probe. - Canonical parameter names for registers 84-89 and 152-157 (#201): the Forced Discharge and AC First schedule registers previously surfaced as raw numeric keys from
read_named_parameters; they now decode toHOLD_FORCED_DISCHARGE_TIME_*/HOLD_AC_FIRST_TIME_*. (The known-stale 68-73 AC Charge names are deliberately unchanged — downstream alias chains depend on them.)
Suite: 2525 passed. Consumed by eg4_web_monitor v3.4.0-beta.20.