Changed

  • Response-paced command transmission: the TX loop waits for the previous command's response (5s safety timeout) instead of sleeping a fixed 100ms after every serial write. Command round-trips drop from ~130ms to gateway speed (~30–40ms); full device discovery is roughly 3x faster.
  • Device-aware update callbacks: register_callback callbacks may now accept the changed device as a single positional argument. Parameterless callbacks keep working. Callbacks fire only when a device actually changed, and a failing callback no longer breaks the others.
  • Lazy logging in hot paths; XML header repair only when the broken header is present.

Fixed

  • Gateway error responses stalled callers for the full 10s timeout (plus retry) — faults now resolve the pending future with False immediately.
  • updateAllDevices() crashed with AttributeError (iterated dict keys instead of devices).
  • processTeachResponse was never awaited, so teach/scan result processing never ran.
  • Sender events were stored into the sensor registry, overwriting sensors with the same id.

Verified against live gateway hardware.