  • WebSocket silently runs on stale data after the 2-hour Husqvarna server session limit (#34). Husqvarna's API enforces a server-side 2-hour maximum duration on WebSocket connections for load-balancing purposes. When that limit is reached the server sends a graceful WS CLOSE frame; the aiogardenasmart library exits its receive loop normally (no exception), so _on_ws_error was never called, _ws_connected stayed True, and the coordinator silently ran on stale data until the 4-hour watchdog fired — a silent data gap of up to 2 hours.

    Fix: a one-shot timer (WS_MAX_SESSION_SECONDS = 6900 s, i.e. 1 h 55 min — 5 minutes before the server limit) is now scheduled every time a WebSocket session is established. When the timer fires, _async_ws_session_expired() proactively disconnects and schedules a normal reconnect through the same _schedule_ws_reconnect() path used by every other recovery code-path. The timer is cancelled on explicit error or shutdown so it does not fire on a connection that has already been torn down.

    Thanks @tomasszabo for the investigation and fix.