v0.3.0
Focus of this release: make the assistant reason like a KNX engineer, not just call the API. The MCP server surfaces parameter and communication-object meaning, validates before it mutates, and keeps large-project reads focused.
Highlights
- Parameter semantics —
params.listreturns each parameter'stext(label),unit,access, enumoptions(value + label), and numericmin/max, plus documentedisActive(post-visibility) meaning. Pick a valid value instead of guessing. - Communication-object channel grouping — every ComObject is tagged with its
channel/function label where the product exposes it. Where it does not, the channel is in the object'stext(e.g. "Output A") and the function infunctionText(e.g. "Move blinds up-down"); group bychannelif present, elsetext. - DPT-compatibility check on link —
linkreturns adptWarningwhen a com-object and group address have different DPT main numbers (the link still proceeds), catching wrong wiring early. - Batch pre-flight validation —
batch_apply(validate_only=True)runs read-only checks (required params, link com-object exists + active, GA exists, DPT match, GA address collision) and reports per-op issues without mutating. Validate a large batch, fix the flagged ops, then apply. - Focused reads —
list_parametersdefaults toactive_only=True(only currently-relevant parameters; passactive_only=falsefor the full set) and supportsname_contains.list_comobjectssupportsname_contains(matches text/functionText/channel). - Find by human label —
list_devicesandlist_group_addressesgained aname_containsfilter that also matchesdescription/comment(device also product/order/address). A device whose label lives in its description, or a GA whose label lives in its description, is now findable. - Engineering guidance baked in — the MCP server instructions are a compact KNX engineering guide (domain model, the parameter → com-object ordering trap, inspect → plan → apply → verify) and the assistant is told to ask the user for the device's technical-manual PDF for correct parametrization.
Fixes
- Linking a just-activated com-object — after a parameter change activates a com-object, linking it no longer wrongly fails with
inactive_object; com-object lookup now uses the active collection (the full collection could retain a stale inactive flag). - Large
params.list— the transport frame limit was raised 4 MB → 16 MB so parameter-heavy devices (12k+ parameters) no longer overflow the client.
Reliable targeting on complex devices
blockon communication objects — each object now carries its authoritative ETS group-object-tree path (e.g. "Operation / Display > Push button functions > PB9/10: Push buttons 9/10"), so you can reliably tell which function/block an object belongs to instead of guessing from names.blockon parameters — every parameter now also carries its UI path (parsed from the application-program dynamic tree, cached). On multi-function devices the same parameter name repeats many times; select byblock+name+isActive(a unique triple) to target the correct instance instead of guessing.application.dynamic— returns the device application program's dynamic UI tree (ParameterBlock/Channel/ParameterRefRef) as XML, the authoritative source for mapping a parameter to its UI block/channel on multi-function devices.
Compatibility
- Runs on ETS 5 and ETS 6 (a single ETS 6 build covers 6.3 and 6.4). Additions are optional fields / new parameters.
- Note:
link.createnow returns{ comObjectRef, gaRef, dpt?, gaDpt?, dptWarning? }instead of{ ok }.
Install
Download knx-ets-mcp-v0.3.0.zip, extract the whole zip, run install.bat, then start Start-MCP-Server.exe. See the README for client setup.
v0.2.0