stateDiagram-v2
[*] --> REFILL_OP_IDLE : Send pair_nozzle(0076) to pair nozzle device and fetch Fleet info to initiate the machine
note left of REFILL_OP_IDLE
-System in standby
-Monitoring for start triggers
-Check system health by sending heartbeat() and expect heartbeat(0)
end note
REFILL_OP_IDLE --> REFILL_OP_ERROR: Heartbeat timeout
REFILL_OP_IDLE --> REFILL_OP_START: Start Process (HTTP Fill Request)
note left of REFILL_OP_START
-Initialize & Request RFID
-Send rfid_get(0076) every 5 second until you receive a tag (3min timeout)
-Validate Tag
end note
REFILL_OP_START --> REFILL_GET_FIRST_RFID:
REFILL_GET_FIRST_RFID --> REFILL_OP_IDLE: Timeout/Error (2 mins)
REFILL_GET_FIRST_RFID --> REFILL_WAIT_FOR_DRF_SUBMIT: Valid RFID Read
note left of REFILL_WAIT_FOR_DRF_SUBMIT
-Wait for Http POST json KM info
-Check KM info, make sure it's less than 1000
end note
REFILL_WAIT_FOR_DRF_SUBMIT --> REFILL_OP_IDLE: Timeout (2 mins)
REFILL_WAIT_FOR_DRF_SUBMIT --> REFILL_READ_FIRST_METER: Vehicle OK to Refill
note left of REFILL_READ_FIRST_METER
-Reset the meter reading meter_reset() && wait for meter_read(0)
end note
REFILL_READ_FIRST_METER --> REFILL_OP_IDLE: Error
REFILL_READ_FIRST_METER --> REFILL_WAIT_FIRST_RFID_MATCH: Meter Active
note left of REFILL_WAIT_FIRST_RFID_MATCH
-rfid_get_cont(params) && wait rfid_match()
end note
REFILL_WAIT_FIRST_RFID_MATCH --> REFILL_OP_IDLE: Timeout (no rfid_match())
REFILL_WAIT_FIRST_RFID_MATCH --> REFILL_PROGRESS: RFID Match
note left of REFILL_PROGRESS
-Expect continous rfid_match()
-Wait for alarm (rfid_alarm(0076) in case Nozzle can't read tag anc can't send rfid_match)
-If no Nozzle heartbeat then Comm Lost (expect continous nhb(0076,0))
-Continously read meter; meter_read() and record the latest value
-Expect the answer with changing values; meter_read(64)
end note
REFILL_WAIT_FIRST_RFID_MATCH --> REFILL_WAIT_APP_INFORM: Database Error
REFILL_PROGRESS --> REFILL_INTERRUPT: RFID Error/Comm Lost
note left of REFILL_INTERRUPT
-Refill is interrupted, record the reason
-Send rfid_get() every 5 seconds to re-estabilish the connection
end note
REFILL_INTERRUPT --> REFILL_PROGRESS: RFID Recovered
REFILL_PROGRESS --> REFILL_LAST_METER_READ: Stop Conditions Met
REFILL_INTERRUPT --> REFILL_LAST_METER_READ: Max Retries
note left of REFILL_LAST_METER_READ
-Refill is completed
-Keep reading the meter to ensure the meter stop changing (meter_read())
end note
REFILL_LAST_METER_READ --> REFILL_WAIT_METER_STABILITY: Unstable Reading
REFILL_LAST_METER_READ --> REFILL_WAIT_APP_INFORM: Reading Complete
REFILL_WAIT_METER_STABILITY --> REFILL_LAST_METER_READ: After 5s
REFILL_WAIT_APP_INFORM --> REFILL_OP_IDLE: App Informed/Timeout
note left of REFILL_WAIT_APP_INFORM
-Wait for the GET request to fetch the results
end note
REFILL_FORCE_STOP --> REFILL_LAST_METER_READ: Liters > 0
REFILL_FORCE_STOP --> REFILL_WAIT_APP_INFORM: Liters = 0
Folders and files