Skip to content

fortigate hardware-health blacklist and threshold problem #234

Description

@dcec

Is possible to use blacklist for Fortigate sensor?
In my case i want to skip "RPS 12V" sensor.
Then disk threshold calculation not work fine, in my case 0.94%;80;90 result critical.

/check_nwc_health' '--community' 'diesel' '--hostname' '10.10.10.10' '--mode' 'hardware-health' --verbose
CRITICAL - sensor RPS 12V alarm status is true, disk is 0.94% full
checking sensors
sensor +3.3V alarm status is false
VCC 2V5 alarm status is false
sensor MAIN 12V alarm status is false
VCC 1V15 alarm status is false
DDR3 VTT alarm status is false
sensor RPS 12V alarm status is true
sensor NCT +3.3V alarm status is false
sensor NCT VBAT alarm status is false
sensor NCT +3.3VSB alarm status is false
sensor NCT VTT alarm status is false
sensor DTS CPU alarm status is false
sensor +5V alarm status is false
sensor CPU Core 0 alarm status is false
sensor CPU Core 1 alarm status is false
Temp TD1 alarm status is false
Temp TD2 alarm status is false
sensor FAN_TMP_3 alarm status is false
Temp LM75 U72 alarm status is false
Temp LM75 U65 alarm status is false
Temp LM75 U62 alarm status is false
sensor FAN1 alarm status is false
sensor FAN2 alarm status is false
sensor +12V alarm status is false
sensor FAN3 alarm status is false
CPU VCCP alarm status is false
sensor CPU VTT alarm status is false
sensor CPU PVSA alarm status is false
P1V8 alarm status is false
P1V5 alarm status is false
sensor PCH +1.05V alarm status is false
checking disks
disk is 0.94% full | 'sensor_+3.3V'=3.29;;;; 'volt_VCC 2V5'=2.46;;;; 'sensor_MAIN 12V'=11.90;;;; 'volt_VCC 1V15'=1.14;;;; 'volt_DDR3 VTT'=0.74;;;; 'sensor_NCT +3.3V'=3.26;;;; 'sensor_NCT VBAT'=3.26;;;; 'sensor_NCT +3.3VSB'=3.26;;;; 'sensor_NCT VTT'=1.04;;;; 'sensor_DTS CPU'=57;;;; 'sensor_+5V'=5.05;;;; 'sensor_CPU Core 0'=58;;;; 'sensor_CPU Core 1'=53;;;; 'temp_TD1'=50;;;; 'temp_TD2'=41;;;; 'sensor_FAN_TMP_3'=48;;;; 'temp_LM75 U72'=44;;;; 'temp_LM75 U65'=44;;;; 'temp_LM75 U62'=48;;;; 'sensor_FAN1'=4700;;;; 'sensor_FAN2'=5000;;;; 'sensor_+12V'=12.08;;;; 'sensor_FAN3'=4800;;;; 'volt_CPU VCCP'=0.98;;;; 'sensor_CPU VTT'=1.05;;;; 'sensor_CPU PVSA'=0.93;;;; 'volt_P1V8'=1.77;;;; 'volt_P1V5'=1.48;;;; 'sensor_PCH +1.05V'=1.04;;;; 'disk_usage'=0.94%;80;90;0;100

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions