v.1.9.54b
1-Click SeedVR 2.5 — Release Notes (v1.9.48b → v1.9.54b)
Everything new since v1.9.47b.
v1.9.54b — last_used.json relocation
- last_used.json moved next to config.json (project root) — processing
settings and app settings live side by side; named presets stay in the
configurable presets directory.
v1.9.53b — Temp directory, persistent logs, one-click log shipping
- Temp moved to
C:\1Click_SeedVR2.5\temp— all transient work (queue
files, previews, chunk runs) lives with the other shared assets
(python_embeded,models,presets), configurable via the Temp
directory setting. - "Log directory" setting row in Settings — where
app.log,
error.logand failure reports are written. - Debug output ON by default.
- access.log — every CLI log line is appended (timestamped) across
sessions. Show Log opens with previous-run history (last 3000 lines)
instead of a blank window; Clear wipes both view and file. - Send Logs button on the error dialog — zips
error.log,
access.log,app.logandconfig.jsonand emails the archive to the
developer fully in the background. SMTP credentials are embedded in the
binary (obfuscated, never shown in the UI) — zero configuration.
v1.9.52b — Single config.json + dedicated log/presets directories
- One config.json, in the project root only. The EXE (inside
dist\)
anchors one level up, so source runs and the frozen EXE read/write the
same file —dist\config.jsonanddist\tempare gone for good. - config.json contains only the Settings-dialog values (runtime paths,
temp/presets/log directories, alarm, systray, session I/O). - Processing settings (batch, tiles, model, offloads…) live in
presets\last_used.json— separated by design. - New
log\directory for app/error/failure logs, configurable via the
"Log directory" setting. - Presets directory is configurable ("Presets directory" setting,
defaultC:\1Click_SeedVR2.5\presets).
v1.9.51b — Executable renamed
SeedVR2_GUI.exe→1-Click_SeedVR_2.5.exe(InternalName and
OriginalFilename metadata updated as well).
v1.9.50b — Application renamed
- Display name is now "1-Click SeedVR 2.5" (window title, tray tooltip,
EXE file description, product name).
v1.9.49b — System tray toggle
- New System tray on/off switch in Settings (below Alarm sounds),
persisted in config.json, default on.- ON: closing the window hides the app to the tray; processing
continues in background; full quit via the tray menu. - OFF: no tray icon; closing the window really quits the app.
- ON: closing the window hides the app to the tray; processing
- Applies immediately — no restart needed.
v1.9.48b — Standard output colors, error reporting, voice alerts
Standard-compliant output colors (breaking fix)
- The raw RGB pipe reached NVENC and was encoded as GBR 4:4:4
(Main 4:4:4+ identity matrix) — many editors/players misinterpret it
and shift colors. The writer now forces-pix_fmt yuv420pplus an
explicit bt709 RGB→YUV matrix (-vf scale=out_color_matrix=bt709:out_range=tv),
so output isMain / yuv420p / bt709 / tv— the same standard combo
ComfyUI writes. Verified with a real NVENC encode + ffprobe. - Image-sequence export gets the same matrix fix. RGB targets (FFV1,
ProRes 4444) unaffected.
Detailed failure reporting
- Failures no longer show a bare "Exit code 1": the dialog opens with
details expanded, headed by the most meaningful error line, and the full
report (command + last 100 log lines) is saved to
log\cli_failure_<timestamp>.logwith Copy-to-Clipboard.
Voice (TTS) notifications
- Success/failure alarms now speak via Windows SAPI ("Processing completed
successfully." / "An error occurred during processing."), falling back to
the old chime when no voice is installed.
Project panel outcome colors
- Finished files turn green, failures red, cancellations amber.
Export defaults
- Quality level defaults to High (codec default was already H265).
Other
- Removed the non-functional "Side by Side" preview button.
- 7B config selection is case-insensitive — a file named with an uppercase
"7B" no longer silently loads the 3B config and fails with a confusing
architecture mismatch. Dry-run structure test passes for all 9 registered
DiT models (3B/7B/sharp, GGUF/fp8/fp16).