Notifications
You must be signed in to change notification settings - Fork 1
NCINMAPI User Manual
Current documented release: NCINM3.20260510
NCINMAPI provides REST-style access to the NCINM3 radiopharmaceutical dose
calculation workflow. A client sends one JSON object to /param; the server
matches the requested phantom and radiopharmaceutical, calculates organ doses,
and returns JSON output.
The API currently supports the NCI and ICRP phantom-library radiopharmaceutical workflow. Fetus phantom calculations are available in the NCINM3 GUI through the Radionuclide tab with user-entered maternal source-region data; they are not included in the radiopharmaceutical API because pregnancy-specific radiopharmaceutical biokinetic models are not currently defined.
Cloud endpoint:
POST https://ncinm-api.ncidosetools.com/param
Content-Type: application/json
X-API-Key: <assigned vendor API key>
A vendor-specific API key is provided after the commercial licensing agreement is executed.
Local Xojo debug endpoint:
POST http://localhost:8080/param
Content-Type: application/json
X-API-Key: <assigned vendor API key>
POST /param requires the API key assigned to the licensed vendor. Send the
key in the X-API-Key request header. Do not include it in the URL or JSON
body. Missing, disabled, or invalid keys return HTTP 401.
The API key is a bearer credential. Store it in an environment variable or a server-side secret manager, and send requests only over HTTPS. Server-to-server integration is recommended. Do not commit the key to source control, write it to application logs, embed it in browser JavaScript, or distribute it inside a desktop or mobile application. Use a vendor-controlled backend as a proxy when the end-user application cannot protect a secret.
The same assigned company key is accepted by NCICTAPI, NCINMAPI, and NCIRFAPI. If a key may have been exposed, stop using it and contact the NCI Dose Tools administrator to have it disabled or rotated. Successful requests are logged under the registered company name; the raw key is not written to the API access log.
Save one of the JSON examples below as request.json. For an interactive test,
read the key without placing it in shell history:
read -rsp "NCI Dose API key: " NCIDOSE_API_KEY && printf '\n'
export NCIDOSE_API_KEY
curl https://ncinm-api.ncidosetools.com/param \
-H 'Content-Type: application/json' \
-H "X-API-Key: ${NCIDOSE_API_KEY}" \
--data @request.json
unset NCIDOSE_API_KEYProvide NCIDOSE_API_KEY to the Python process through the deployment
environment or secret manager. Do not put the raw key in the source file.
import json
import os
import requests
with open("request.json", encoding="utf-8") as request_file:
payload = json.load(request_file)
response = requests.post(
"https://ncinm-api.ncidosetools.com/param",
headers={"X-API-Key": os.environ["NCIDOSE_API_KEY"]},
json=payload,
timeout=120,
)
response.raise_for_status()
print(response.json())Ready-to-run local examples are provided in:
_ncinm3api_test.http
The API accepts one JSON object per request.
| Parameter | Required | Definition |
|---|---|---|
phantom_library |
yes | Phantom library. Use 1 for NCI phantoms and 2 for ICRP phantoms. Fetus phantom calculations are not currently supported by the radiopharmaceutical API. |
sex |
yes | Patient sex. Use 1, f, or female for female; use 2, m, or male for male. |
age |
yes | Patient age in years. Any non-negative numeric age is accepted and matched to the nearest available age phantom. |
radiopharmaceutical |
yes | Exact library name or clinical-style text such as F-18 FDG or Tc-99m MDP. |
administered_activity_mbq |
yes | Administered activity in MBq. Must be greater than zero. |
Supported aliases:
| Canonical parameter | Accepted aliases |
|---|---|
phantom_library |
phantomLibrary, PhtLib, phtlib, phantom
|
sex |
Sex, gender, Gender
|
age |
Age, patient_age, patientAge
|
radiopharmaceutical |
Radiopharmaceutical, radiopharmaceutical_name, radiopharmaceuticalName, clinical_radiopharmaceutical, clinicalRadiopharmaceutical, rpharm, RPharm
|
administered_activity_mbq |
activity_mbq, activity, MBq, mbq
|
The API maps patient age to the nearest available NCINM3 age group:
| Input age | Matched phantom age |
|---|---|
0 <= age < 0.5 |
0 year |
0.5 <= age < 3 |
1 year |
3 <= age < 7.5 |
5 years |
7.5 <= age < 12.5 |
10 years |
12.5 <= age < 18 |
15 years |
age >= 18 |
Adult |
The response reports the matched phantom age. In API input and output,
sex = 1 is female and sex = 2 is male.
The API can accept either a library ID or clinical-style text. When a radiopharmaceutical name is received in JSON input, NCINMAPI automatically matches the submitted text to the closest library entry using fuzzy matching.
Matching is performed in this order:
- Numeric ID match, when
radiopharmaceuticalcontains only an ID. - Exact text match against the available radiopharmaceutical names.
- Fuzzy text match against the available radiopharmaceutical names.
The fuzzy matcher normalizes radionuclide notation before matching. Examples:
| Input notation | Normalized notation |
|---|---|
18F, F18, 18 F, F-18
|
F-18 |
99mTc, Tc99m, Tc-99m
|
Tc-99m |
I123, 123I, I-123
|
I-123 |
201Tl, Tl201, Tl-201
|
Tl-201 |
Fuzzy matching stays within the same radionuclide when a radionuclide is provided. If no radiopharmaceutical with that radionuclide is available, the API returns an error instead of matching to a different radionuclide.
The response includes both the original submitted text and the matched library entry so vendors can audit automatic matches.
{
"phantom_library": 2,
"sex": "female",
"age": 58,
"radiopharmaceutical": "F-18 FDG",
"administered_activity_mbq": 200
}{
"PhtLib": 1,
"Sex": "m",
"Age": 42,
"Radiopharmaceutical": "Tc99m MDP bone scan",
"MBq": 740
}{
"phantom_library": 2,
"sex": 1,
"age": 8,
"radiopharmaceutical": "20",
"administered_activity_mbq": 200
}Successful responses return HTTP 200 and a JSON object.
| Top-level key | Definition |
|---|---|
ok |
true for successful calculations. |
input |
Parsed and resolved input values used for calculation. |
phantom_age_match |
Original age, matched phantom age, and matching method. |
radiopharmaceutical_match |
Original text, matched library name, method, score, and optional warning. |
dose_mGy |
Organ absorbed doses in mGy. effective_dose_mSv is reported in mSv. |
Example response structure:
{
"ok": true,
"input": {
"phantom_library": 2,
"sex": 1,
"age": 58.0,
"matched_phantom_age": "Adult",
"radiopharmaceutical_original": "F-18 FDG",
"radiopharmaceutical": "F-18-fluoro-2-deoxy-D-glucose (FDG) (ICRP 128)",
"administered_activity_mbq": 200.0
},
"phantom_age_match": {
"original_age_year": 58.0,
"matched": "Adult",
"method": "nearest_available_age_phantom"
},
"radiopharmaceutical_match": {
"original": "F-18 FDG",
"matched": "F-18-fluoro-2-deoxy-D-glucose (FDG) (ICRP 128)",
"method": "fuzzy",
"score": 1.0
},
"dose_mGy": {
"adipose": 0.0,
"brain": 0.0,
"thyroid": 0.0,
"effective_dose_mSv": 0.0
}
}Dose values in the example are illustrative placeholders. Actual values depend on the matched phantom, radiopharmaceutical, and administered activity.
dose_mGy contains these dose keys:
adipose, adrenal, adrenal_l, adrenal_r, bronchi, brain,
breast_adipose, breast_glandular, colon_w, colon_w_l, colon_w_r,
et, gall_bladder_w, gonads, heart_w, kidney, kidney_r, kidney_l,
kidney_cortex_l, kidney_cortex_r, kidney_medulla_l, kidney_medulla_r,
kidney_pelvis_l, kidney_pelvis_r, lenses_of_eye, liver, lung,
lung_l, lung_r, lymph_nodes_et, lymph_nodes_but_et_th,
lymph_nodes_thoracic, muscle, nasal_passage_ant, nasal_passage_post,
oesophagus, oral_mucosa, pancreas, pituitary_gland,
prostate_or_uterus, salivary_glands, sigmoid_rectum_w, skin,
small_intestine_w, spinal_cord, spleen, stomach_w, thymus, thyroid,
tongue, tonsils, ureters, urinary_bladder_w, active_marrow,
shallow_marrow, effective_dose_mSv
All organ dose keys are in mGy except effective_dose_mSv, which is in mSv.
Invalid input returns ok: false, HTTP status 400, and an explanatory error
string.
{
"ok": false,
"status": 400,
"error": "Invalid radiopharmaceutical: No radiopharmaceutical with the same radionuclide is available in this library."
}Common validation errors include:
- invalid JSON input
- missing or invalid
phantom_library - missing or invalid
sex - negative
age - missing or unmatched radiopharmaceutical
-
administered_activity_mbqless than or equal to zero
Server-side calculation or installation problems return HTTP 500 with an
error message.