Feedin-limited discharge started immediately instead of deferring: large batteries with small feedin limits (e.g. 42 kWh battery, 1 kWh feedin, 51 min window) started forced discharge immediately at low paced power (~1.5 kW) for the entire window, creating sustained grid import risk. Now defers until the feedin deadline and discharges at full power, maximising headroom above household load (D-005, C-001).
Discharge session lost after HA restart during deferred phase: when HA restarted before a scheduled discharge window opened, session recovery looked for a ForceDischarge schedule on the inverter. Since the schedule isn't written until the window opens, recovery found nothing and discarded the valid session. Now correctly re-creates the session in deferred state, matching charge recovery behaviour (C-024, D-002).
WebSocket connected before discharge window opened: calling smart_discharge (or smart_charge) before the window start time caused WebSocket to connect immediately during the "scheduled" phase. WS now waits until the window actually opens. Also fixed the same issue for charge sessions in smart_sessions mode.
Discharge deferred countdown not shown on card: the badge next to "Discharge Deferred" showed a bare duration (e.g. "2h 15m") without indicating it was a countdown to discharge start. Now shows "discharges in 2h 15m" (localised in all 10 languages).