iSCSI CHAP Authentication

CHAP (Challenge-Handshake Authentication Protocol) protects iSCSI traffic between the Proxmox node (initiator) and JovianDSS (target). Without it, any host on the SAN that knows a target IQN can attach to the LUN. With CHAP enabled, JovianDSS challenges the initiator at login time and refuses connections that cannot produce the correct response.

The plugin uses a single shared credential per storage instance — one username and password applied to all iSCSI targets managed by that storage.


Requirements

  • JovianDSS firmware with iSCSI CHAP support
  • CHAP password: minimum 12 characters, maximum 16 characters (iSCSI RFC 3720 limit)
  • Proxmox VE plugin version 0.10.5 or later

Enabling CHAP

CHAP is configured with three properties: chap_enabled, chap_user_name, and chap_user_password. All three must be set together.

When adding a new storage:

pvesm add joviandss jdss-Pool-0 \
    --ssl_cert_verify 0 \
    --path /mnt/pve/jdss-Pool-0 \
    --create-base-path 1 \
    --shared 1
    --pool_name Pool-0 \
    --user_name admin \
    --user_password <rest-api-password> \
    --control_addresses 192.168.28.100 \
    --data_addresses 192.168.29.100 \
    --chap_enabled 1 \
    --chap_user_name <chap-user-name> \
    --chap_user_password <chap-password>

On an existing storage:

pvesm set jdss-Pool-0 \
    --chap_enabled 1 \
    --chap_user_name <chap-user-name> \
    --chap_user_password <chap-password>

The plugin validates that chap_user_name and chap_user_password are both present when chap_enabled is set to 1. If either is missing the command fails immediately with an error.

What gets written where

chap_enabled and chap_user_name are stored in /etc/pve/storage.cfg and replicated to all cluster nodes automatically by Proxmox VE.

chap_user_password is a sensitive property — it is never written to storage.cfg. Instead it is stored in the private password file on each node:

/etc/pve/priv/storage/joviandss/<storeid>.pw

The file holds both the REST API password and the CHAP password, one per line:

chap_user_password <chap-password>
user_password      <rest-api-password>

Disabling CHAP

pvesm set jdss-Pool-0 --chap_enabled 0

Active iSCSI sessions are unaffected — CHAP is only checked at login time. The change takes effect the next time a VM is started or migrated.


Password Rotation

To change the CHAP password without downtime:

pvesm set jdss-Pool-0 --chap_user_password <new-password>

Active sessions continue uninterrupted. On the next VM start, if the new password does not yet match what JovianDSS has stored for the target, the plugin detects the authentication failure (iscsiadm exit code 24), automatically pushes the new password to JovianDSS, and retries the login. No manual intervention is required.


How It Works During VM Activation

Each volume_activate call runs two phases:

1. Publish — creates or verifies the iSCSI target on JovianDSS and attaches the LUN. When CHAP is enabled, --chap-user and --chap-password are passed to jdssc targets create. JovianDSS sets incoming_users_active: true on the target, meaning it will challenge every initiator at login.

2. Stage — logs the Proxmox node into the target via iscsiadm. The plugin writes CHAP credentials to the iscsiadm node database before calling --login, so the initiator can respond to the challenge. If login fails with an authorization error (exit code 24), the plugin performs one automatic recovery:

  • Pushes current credentials from the .pw file to JovianDSS via jdssc target update.
  • Retries --login with fresh credentials.

If the second attempt also fails, the plugin stops and logs:

CHAP authentication failed for target <targetname> on hosts <hosts>
after credential refresh — check CHAP configuration

Troubleshooting

chap_user_name is required when chap_enabled is set

pvesm set was called with chap_enabled 1 but chap_user_name was not provided. Set both properties in the same command.

chap_user_password is required when chap_enabled is set

chap_user_password is missing from the .pw file. Re-run pvesm set with --chap_user_password.

CHAP authentication failed ... after credential refresh

The credentials in the .pw file do not match what JovianDSS has stored for the target, and the automatic recovery also failed. Check:

  1. pvesm set jdss-Pool-0 --chap_user_password <current-password> — ensure the .pw file holds the correct password.
  2. On JovianDSS, inspect the target's incoming users via the web UI or REST API and verify the username matches chap_user_name.

iscsiadm sessions do not use CHAP after enabling it

Existing sessions are not affected by a configuration change. Stop the VM, which logs out the iSCSI session, then start it again. The new session will be established with CHAP.

Clone this wiki locally