CHAP Authentication
CHAP (Challenge-Handshake Authentication Protocol) protects iSCSI traffic between the Proxmox node (initiator) and JovianDSS (target). Without it, any host on the SAN that knows a target IQN can attach to the LUN. With CHAP enabled, JovianDSS challenges the initiator at login time and refuses connections that cannot produce the correct response.
The plugin uses a single shared credential per storage instance — one username and password applied to all iSCSI targets managed by that storage.
- JovianDSS firmware with iSCSI CHAP support
- CHAP password: minimum 12 characters, maximum 16 characters (iSCSI RFC 3720 limit)
- Proxmox VE plugin version 0.10.5 or later
CHAP is configured with three properties: chap_enabled, chap_user_name, and
chap_user_password. All three must be set together.
When adding a new storage:
pvesm add joviandss jdss-Pool-0 \
--ssl_cert_verify 0 \
--path /mnt/pve/jdss-Pool-0 \
--create-base-path 1 \
--shared 1
--pool_name Pool-0 \
--user_name admin \
--user_password <rest-api-password> \
--control_addresses 192.168.28.100 \
--data_addresses 192.168.29.100 \
--chap_enabled 1 \
--chap_user_name <chap-user-name> \
--chap_user_password <chap-password>On an existing storage:
pvesm set jdss-Pool-0 \
--chap_enabled 1 \
--chap_user_name <chap-user-name> \
--chap_user_password <chap-password>The plugin validates that chap_user_name and chap_user_password are both present
when chap_enabled is set to 1. If either is missing the command fails immediately
with an error.
chap_enabled and chap_user_name are stored in /etc/pve/storage.cfg and
replicated to all cluster nodes automatically by Proxmox VE.
chap_user_password is a sensitive property — it is never written to storage.cfg.
Instead it is stored in the private password file on each node:
/etc/pve/priv/storage/joviandss/<storeid>.pw
The file holds both the REST API password and the CHAP password, one per line:
chap_user_password <chap-password>
user_password <rest-api-password>
pvesm set jdss-Pool-0 --chap_enabled 0Active iSCSI sessions are unaffected — CHAP is only checked at login time. The change takes effect the next time a VM is started or migrated.
To change the CHAP password without downtime:
pvesm set jdss-Pool-0 --chap_user_password <new-password>Active sessions continue uninterrupted. On the next VM start, if the new password does not yet match what JovianDSS has stored for the target, the plugin detects the authentication failure (iscsiadm exit code 24), automatically pushes the new password to JovianDSS, and retries the login. No manual intervention is required.
Each volume_activate call runs two phases:
1. Publish — creates or verifies the iSCSI target on JovianDSS and attaches
the LUN. When CHAP is enabled, --chap-user and --chap-password are passed to
jdssc targets create. JovianDSS sets incoming_users_active: true on the target,
meaning it will challenge every initiator at login.
2. Stage — logs the Proxmox node into the target via iscsiadm. The plugin
writes CHAP credentials to the iscsiadm node database before calling --login,
so the initiator can respond to the challenge. If login fails with an authorization
error (exit code 24), the plugin performs one automatic recovery:
- Pushes current credentials from the
.pwfile to JovianDSS viajdssc target update. - Retries
--loginwith fresh credentials.
If the second attempt also fails, the plugin stops and logs:
CHAP authentication failed for target <targetname> on hosts <hosts>
after credential refresh — check CHAP configuration
chap_user_name is required when chap_enabled is set
pvesm set was called with chap_enabled 1 but chap_user_name was not provided.
Set both properties in the same command.
chap_user_password is required when chap_enabled is set
chap_user_password is missing from the .pw file. Re-run pvesm set with
--chap_user_password.
CHAP authentication failed ... after credential refresh
The credentials in the .pw file do not match what JovianDSS has stored for the
target, and the automatic recovery also failed. Check:
-
pvesm set jdss-Pool-0 --chap_user_password <current-password>— ensure the.pwfile holds the correct password. - On JovianDSS, inspect the target's incoming users via the web UI or REST API
and verify the username matches
chap_user_name.
iscsiadm sessions do not use CHAP after enabling it
Existing sessions are not affected by a configuration change. Stop the VM, which logs out the iSCSI session, then start it again. The new session will be established with CHAP.