v1.1.0
Date: 2026-07-06
Previous release: v1.0.0
Summary
Codec-aware fixtures: write typed values in JSON instead of hand-encoding Modbus registers. Still modbus-simulator.fixture.v1 — raw uint16/bool points remain fully supported.
- Codec register fields — optional
codec(go-modbus stable ID) and typedvalueon holding/input register points. Register span is derived from the codec; values are encoded to wire registers at load time. - Two-tier validation — JSON Schema (
oneOfraw vs codec point) plus semantic checks: codec registry lookup, value coercion, encode/decode round-trip, non-overlapping address spans. codecs list— discover available codec IDs and metadata (--family,--format json). Wrapsgithub.com/otfabric/go-modbus/codec.run --trace-decoded— optionaldecoded[]overlay on trace records when codec fields are fully contained in the request window.- Examples — nineteen fixtures in
examples/: ten function-code fixtures plus nine codec bundles (one per go-modbus codec family: integer, float, text, bcd, bytes, decimal_limb, time, network, hardware_address). Together they cover every stable ID fromcodecs list(195 codecs) with non-overlapping addresses and round-trip-validated sample values. Regenerate bundles withmake generate-codec-examples(tools/generate-codec-examples). TCP integration tests exercise each fixture;TestExamples_AllCodecsHaveExampleguards full codec coverage.
Fixture codec example
{
"schemaVersion": "modbus-simulator.fixture.v1",
"devices": [{
"unitId": 1,
"state": {
"holdingRegisters": [
{ "address": 10, "codec": "float32/layout:4321", "value": 230.5, "name": "voltage" }
]
}
}]
}Run modbus-simulator codecs list for all stable IDs. See go-modbus CODECS.md for layout and value-kind details.
Example fixtures (v1.1.0)
| Fixture | Family | Codecs |
|---|---|---|
codec-integers.json |
integer | 29 |
codec-floats.json |
float | 8 |
codec-text.json |
text | 60 |
codec-bcd.json |
bcd | 48 |
codec-bytes.json |
bytes | 26 |
codec-decimal-limb.json |
decimal_limb | 12 |
codec-datetime.json |
time | 8 |
codec-network.json |
network | 2 |
codec-hardware.json |
hardware_address | 2 |
Function-code fixtures (fc01–fc43, all-function-codes.json) are unchanged from v1.0.0.
Install
go install github.com/otfabric/modbus-simulator@v1.1.0Or download a pre-built binary from GitHub Releases.
Requires Go 1.25+ when building from source. Depends on github.com/otfabric/go-modbus v1.1.0+ for the codec registry.
Breaking changes
None. Existing v1 fixtures with raw integer register values validate and run unchanged.
Known limitations
Unchanged from v1.0.0 unless noted:
- TCP only; RTU/serial server and TCP+TLS listen are deferred.
timeoutandconnectionClosefault rules are recorded in traces but approximated on the wire.resetViaControlandreloadFixturestate modes are deferred.- Codec fields are register areas only (no coil/bit codecs). FC16 writes need not align to codec field boundaries; traces still emit per-register
stateChanges. - Trace
decoded[]entries are omitted when a request only partially overlaps a multi-register codec field.
v1.0.0
Date: 2026-07-05
Previous release: none
Summary
First release of the Modbus TCP device simulator for gateway integration and CI testing.
- Fixture-driven simulation —
modbus-simulator.fixture.v1JSON defines one or more devices (coils, discrete inputs, holding/input registers, FC43 identity, exception/fault rules). - Stateful runtime — writes persist in memory; optional
resetOnConnectionper device. - JSONL traces —
run --tracerecordsmodbus-simulator.trace.v1logs with deterministicseq, responses, andstateChanges. - CI assertions —
assert-traceevaluatesmodbus-simulator.expect.v1files (contains,notContains,count,ordered,exact). - CLI —
validate,run,assert-trace,version, and shellcompletion. - Schemas — canonical JSON Schemas in
schemas/(fixture-v1.json,trace-v1.json,expect-v1.json), embedded in the binary for offline validation. - Examples — ten ready-to-run fixtures in
examples/(one per supported FC plus an all-in-one fixture), each covered by TCP integration tests. - License — MIT (LICENSE).
Install
Download the binary for your platform from GitHub Releases, or:
go install github.com/otfabric/modbus-simulator@v1.0.0Requires Go 1.25+ when building from source.
Pre-built binaries are published for linux/amd64, linux/arm64, linux/arm/v7, darwin/amd64, darwin/arm64, windows/amd64, and windows/arm64.
Breaking changes
None (initial release).
Known limitations (v1)
- TCP only; RTU/serial server and TCP+TLS listen are deferred.
timeoutandconnectionClosefault rules are recorded in traces but approximated on the wire (go-modbus handler constraints).resetViaControlandreloadFixturestate modes are deferred.