You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Proxy forwarding used the wrong pumpspy.com server. The proxy was hardcoded to 206.80.104.221, but the SO1000 device actually connects to 173.241.229.38 (verified via packet capture). Requests were going to a different backend with no session context for the device, so rht_parameters returned a config that didn't trigger cycle mode and /rht_outlet_cycles was never sent. The proxy now derives the target from the device's own Host header (www.pumpspy.com:8081) so it follows pumpspy.com regardless of IP changes.
Malformed proxy URL due to trailing space in Host header. The device sends Host: www.pumpspy.com:8081 with a trailing space; the proxy was concatenating it directly into the URL, producing http://www.pumpspy.com:8081 /path which failed to parse. The Host value is now stripped before use.