Description
The LHV (Lower Heating Value) conversion in create_functional_units multiplies by the LHV value instead of dividing. This causes massively inflated demands for non-energy use variables.
LHV is in MJ/kg. To convert energy (MJ) to mass mass (kg): kg = MJ / LHV
Description
The LHV (Lower Heating Value) conversion in
create_functional_unitsmultiplies by the LHV value instead of dividing. This causes massively inflated demands for non-energy use variables.LHV is in MJ/kg. To convert energy (MJ) to mass mass (kg): kg = MJ / LHV