Added

  • Switches and sliders in the user interface for settings listed in
    writeValues; settings without a control are changed with set, and the
    log says so at start.
  • Option deadband to write values on every change instead of only on
    changes beyond 10 W, 0.01 kWh or 1 %.
  • Option https (default on): encrypted connection to the inverter.

Changed

  • All listed values are published in one QuickApp variable values (JSON)
    instead of one variable per value.
  • pollIntervalSec, logLevel and language are options in App.OPTIONS
    at the top of the file App instead of QuickApp variables.
  • Poll interval default 10 s instead of 30 s; minimum 5 s.
  • New defaults for readValues, writeValues and childValues.
  • Changing a setting in a QuickApp variable is replaced by the user
    interface controls and the set action.
  • README: how-to with table of contents near the top, and a scene example
    for reading and writing values.

Fixed

  • Saving the code in the HC3 editor left the user interface without status
    line, refresh button or values: the editor rebuilds the layout from its own
    copy (viewLayout), which was not updated. The QuickApp now writes both and
    rebuilds the complete layout whenever it differs.
  • A number outside the 64-bit integer range (1e20) or infinity for a
    setting raised a Lua error; it is now rejected with a clear message (#20).
  • An error while processing a reading stopped polling for good; the next
    reading is now scheduled first (#20).
  • A drop to zero inside the dead band was never published, so pvPower
    could stay at a few watts overnight (#21).
  • The cleanup of 1.0.0 variables ran on every start and also deleted
    variables a user had created with a value name; it now runs once, removes
    only the variables 1.0.0 created, and restarts only if the controller kept
    the change (#22).

Security

See advisory GHSA-rj7p-2wjf-cw8x. All points require access to the local
network.

  • The login refuses a challenge with fewer than 10000 key derivation
    rounds; a device impersonating the inverter could otherwise obtain a proof
    that allows a fast offline password search.
  • Nonces and the AES-GCM IV came from math.random, which the controller
    does not seed: they repeated after every restart. They now come from a
    SHA-256 pool seeded at start and mixed with the inverter's random values.
  • The session ID was sent in clear text; the connection now uses HTTPS by
    default.
  • Text received from the inverter is escaped before it is shown in the user
    interface (the web interface shows it literally; escaping protects other
    clients that might render HTML).

Upgrade notes

  • On the first start, the QuickApp removes the variables of 1.0.0 that it no
    longer uses (one per value listed in readValues and writeValues,
    pollIntervalSec, logLevel, language) and restarts once. host,
    password, the three lists and all other variables are kept.
  • The connection uses HTTPS. If an inverter does not offer it, set
    https = false in App.OPTIONS.
  • Scenes that read single variables such as batterySoc must read the
    variable values instead (see README, "Reading values").
  • A changed poll interval, log level or language must be set again in
    App.OPTIONS.

v1.0.0

Choose a tag to compare

@github-actions github-actions released this 30 Sep 21:33
1f1b9fc

Warning

Superseded by 1.1.0. Version 1.0.0 has security issues (see advisory GHSA-rj7p-2wjf-cw8x) and a bug that can stop polling. Its package was removed; please use 1.1.0. The upgrade is described in the README.

Added

  • Login to the inverter's local REST API as plant owner.
  • Process data, settings and device information as QuickApp variables,
    selected with readValues and writeValues.
  • set action and two-way synchronisation of settings; changes made on the
    inverter take precedence.
  • Optional child devices (childValues) with stable device IDs.
  • Value table in the user interface with names in English, German, French
    and Italian, and units.
  • Built-in energy meter icon instead of the generic device icon.
  • The QuickApp stops with "Controller not supported" on a Lua without
    64-bit integers, which the inverter login requires.