Auto‐Detection
When OmenMon-Reborn starts on a device whose ProductId is not present in Config.Models (and is not "?"), it offers to run a read-only heuristic scan to determine whether the standard 2022+ EC register layout applies.
On the first time the main window is shown, a dialog appears:

"Unknown Omen model detected (XXXX). Run a safe read-only hardware scan to auto-configure sensors?"
Clicking Yes triggers AutoDetector.DetectHeuristic(productId).
Clicking No dismisses the dialog. The app continues running with PlatformPreset.Default as the fallback — fan control will work correctly if the device happens to share the standard register layout, but there is no guarantee.
The prompt fires once per session only. It is wired to the form's Shown event and unsubscribed immediately after.
If the scan succeeds:

"Auto-configuration saved for XXXX. The standard 2022+ register layout was confirmed on your device."
The preset is written to OmenMon.xml under <Models>. On the next launch, Platform.InitFans() finds it in Config.Models and the prompt never appears again.
If the scan fails (values outside expected ranges), the dialog directs the user to the Contributing Hardware Data tray menu item to file a report with a full EC dump.
Hardware/AutoDetector.DetectHeuristic() performs a full 256-byte read-only EC dump — no writes to any register at any point. It then checks two invariants:
| Register | Address | Expected range | Rationale |
|---|---|---|---|
CPUT |
0x57 |
20–95 °C | CPU temp is always readable on 2022+ Omen hardware; a value outside this range suggests the address maps to something else |
RPM1 (word) |
0xB0–0xB1
|
0–7000 rpm | Fan speed is always present, even at idle; values above 7000 indicate the register is not a fan speed |
If both pass, the device receives a copy of PlatformPreset.Default under its own ProductId. If either fails, null is returned.
// Hardware/AutoDetector.cs (simplified)
bool cputValid = cput >= 20 && cput <= 95;
bool rpm1Valid = rpm1 >= 0 && rpm1 <= 7000;
if(cputValid && rpm1Valid)
return new PlatformPreset { ProductId = productId, ... /* Default values */ };
return null;The EC is a real microcontroller managing battery charging, thermal throttling, and power rails alongside the fans. Writing to an unknown register can permanently latch a fan off, corrupt a thermal threshold, or trigger a hardware protection mode. The scanner deliberately never writes anything — the worst possible outcome of a failed detection is that the user is shown the "could not detect" message and directed to file a report.
| File | Relevant method |
|---|---|
Hardware/AutoDetector.cs |
DetectHeuristic(string productId) |
App/Gui/GuiFormMain.cs |
CheckUnknownModel(), EventFormShown()
|
App/Gui/GuiFormMainInit.cs |
this.Shown += EventFormShown |
Library/Config.cs |
SaveModel(PlatformPreset preset) |