A Home Assistant climate component with separate heating and cooling switch effectors, optional outdoor temperature comparison, and configurable hysteresis.

Features

  • Climate entity — heat, cool, and off modes with separate heat/cool setpoints via a range slider
  • Dual effectors — separate switches for heating and cooling; the opposite effector is always turned off for safety
  • Fully UI-configured — no YAML, set up entirely via the Home Assistant integration flow
  • Temperature sensors — pick any temperature sensor for inside and optional outside
  • Mode selection — independently enable or disable heat/cool modes (heat-only, cool-only, or both)
  • Hysteresis — configurable deadband around target temp to prevent rapid cycling
  • Outside temperature check — per-mode toggles: only cool when outside is cooler than inside, or only heat when outside is warmer
  • Safety shutdown temperatures — configurable hard limits that trigger a persistent notification, disable all effectors, and lock the controller until manually reset

Installation

HACS (recommended)

  1. Add this repository as a custom repository in HACS.
  2. Search for "Simple Climate" and install.
  3. Restart Home Assistant.

Manual

  1. Copy custom_components/simple_climate/ to your Home Assistant custom_components/ directory.
  2. Restart Home Assistant.

Configuration

  1. Go to Settings → Devices & Services → Add Integration.
  2. Search for "Simple Climate" and select it.
  3. Fill in:
    • Name — friendly name for the climate entity
    • Inside temperature sensor — entity that reports indoor temperature
    • Heating switch — switch to turn on for heating
    • Cooling switch — switch to turn on for cooling
    • Heat setpoint — desired temperature for heating
    • Cool setpoint — desired temperature for cooling
    • Default mode — cool, heat, or off
    • Outside temperature sensor (optional) — for the outside check
    • Hysteresis — deadband in °C (default 0.5)
    • Enable heat / cool mode — turn modes on or off independently
    • Check outside temp before heating / cooling — only run when outside conditions help
    • Heat safety max temp — if inside temp exceeds this, emergency shutdown (0 = off)
    • Cool safety min temp — if inside temp drops below this, emergency shutdown (0 = off)

After setup, you can reconfigure any option via Configure on the integration card.

How it works

Cooling (uses the cool setpoint)

  • Cool switch turns on when inside temp > cool setpoint + hysteresis/2
  • Cool switch turns off when inside temp < cool setpoint - hysteresis/2
  • Heat switch is kept off

Heating (uses the heat setpoint)

  • Heat switch turns on when inside temp < heat setpoint - hysteresis/2
  • Heat switch turns off when inside temp > heat setpoint + hysteresis/2
  • Cool switch is kept off

Outside check (optional, per mode)

  • Cooling: cool switch only activates if outside temp is lower than inside
  • Heating: heat switch only activates if outside temp is higher than inside

Safety shutdown temperatures

  • Set a heat safety max temp — if the indoor sensor reads higher, both effectors switch off, a persistent notification is raised, and the controller enters lockout until the user changes any HVAC mode
  • Set a cool safety min temp — same behavior but for the lower bound
  • Set to 0 to disable each limit
  • Lockout survives HA restarts via state restoration

Mode toggles

  • Enable heat only — the climate UI only shows off and heat
  • Enable cool only — the climate UI only shows off and cool
  • Enable both — the climate UI shows off, heat, and cool

Disclaimer

This integration has been quality-checked with black, mypy, pylint, and 28 automated tests covering all core logic paths — hysteresis deadbands, sensor unavailability, outside-temperature checks, dual-effector safety interlocks, dynamic mode toggling, setpoint changes, and config/options fallback.

However, controlling physical equipment (heaters, coolers, pumps, fans) always carries inherent risk. Despite thorough testing, a software bug, sensor failure, network issue, or misconfiguration could theoretically cause an effector to remain stuck on or off, potentially leading to property damage or safety hazards.

Use this integration entirely at your own risk. The author(s) assume no liability for any damage or injury resulting from its use. Always install appropriate hardware-level safety limits (thermal fuses, overflow switches, etc.) and regularly verify correct operation.

License

MIT

About

No description, website, or topics provided.

Resources

Stars

Watchers

Forks

Releases

Packages

Contributors

Languages