2.0.0-beta.7 — control and settings
Pre-releaseTwo new tabs in the panel.
Control
Charge and discharge power, the power and SoC limits, work and force mode, the backup and RS485 switches, all six schedule slots, and a confirmed device restart.
Every control reads its own bounds from the entity rather than hard-coding them, so the same editor is correct on a 1500 W Venus A and a 2500 W Venus D. Schedule times are converted between the HHMM the registers hold and a clock field.
Anything that regulates the battery from outside writes the same registers and will win within seconds. When that happens right after the panel wrote, the tab says so instead of looking broken.
Factory reset is deliberately not offered here; it stays in the entity list.
Settings
Behind a gear in the header. Seven colour schemes — Reactor, Cockpit, Verdant, Plasma, Ember, Glacier, and one that takes its colours from your Home Assistant theme — each with its own light and dark version. Plus a light/dark override, which tab the panel opens on, which tabs to hide, and one extra decimal place.
Settings live in the browser, so each browser keeps its own.
Fixed
- Venus A was offered up to 2500 W for charge and discharge power and in every schedule slot. Its real limit is 1500 W.