Modes

Main

Key Operation
0-9 Edit the current input value.
A Move the planer head up by the current up increment value.
B Move the planer head down by the current down increment value.
C Toggle the sign of the current input value.
D Change to calibration mode.
* Change to main settings.
# Move the planer head to the specified input position.

Calibration

Key Operation
8 Move the planer head up by the current increment value.
0 Move the planer head down by the current increment value.
7 Increase the motor speed.
* Decrease the motor speed.
1 Increase increment value (small).
4 Decrease increment value (small).
2 Increase increment value (medium).
5 Decrease increment value (medium).
3 Increase increment value (large).
6 Decrease increment value (large).
A Increase increment value by one centimeter.
B Decrease increment value by one centimeter.
D Change to main mode.
# Reset the total distance traveled counter.