v1.0.13
v1.0.12
Adds four read-only whole-home meter/CT telemetry sensors for Predbat's load model (House Load, Grid Import/Export Today, House Load Today). No control changes. Run --probe to confirm the Today counters are U16 on your firmware. See CHANGELOG.
v1.0.11
Fixes Battery Voltage (BMS) scaling (0.01V units) — was showing 531V instead of 53.1V. See CHANGELOG.
v1.0.10
Fixes charge/discharge current scaling — registers are 0.1A units, so 105A was commanding 10.5A. Re-test at a low setpoint first. See CHANGELOG.
v1.0.9
Adds heartbeat + discovery logging so a working run is visible and 'no data in HA' is diagnosable. See CHANGELOG.
v1.0.8
Fixes the recurring 33150 timeout (a split 32-bit battery_power pair) by reading targeted, pair-aligned telemetry blocks. Faster cycle, cleaner logs. See CHANGELOG.
v1.0.7
A single read timeout no longer drops the connection — it's skipped like any failed read and the cycle continues. Only a real socket break reconnects. See CHANGELOG.
v1.0.6
Lowers read size to 2 registers (avoids the 0x0A that wedged the gateway) and adds exponential backoff to stop the reconnect storm. See CHANGELOG.
v1.0.5
Splits block reads into 5-register chunks so small gateway response buffers no longer truncate the large telemetry blocks. See CHANGELOG.
v1.0.4
Confirms the gateway is Modbus TCP (MBAP header, no RTU CRC footer) and validates the MBAP header on every reply. Use protocol: tcp. See CHANGELOG.