ARGUS REDLINE Protocol v0.1.0 establishes reliable bidirectional binary LoRa communication between a Hub and Node running on Heltec WiFi LoRa 32 V4 hardware.

Verified capabilities

  • Versioned six-byte binary packet header
  • Explicit source and destination addressing
  • Command opcode support
  • Sequence-matched acknowledgments
  • Packet-length and packet-type validation
  • Bounded acknowledgment retries
  • Duplicate-command suppression
  • Cached acknowledgment replay
  • Automatic recovery after temporary Node loss
  • RSSI and SNR serial diagnostics

Hardware tested

  • 2× Heltec WiFi LoRa 32 V4
  • ESP32-S3
  • Semtech SX1262
  • 915 MHz LoRa configuration

This remains experimental development firmware and is not intended for safety-critical reliance.