Repository navigation
LBA REQ 005
github-actions[bot] edited this page Nov 19, 2026
·
2 revisions
Proposed
User Interface
Directly below the benchmark chart, the viewer shall display the captured picture indexed at the cursor's selected time, updating as the cursor moves.
- The picture shown is the frame whose timestamp is nearest at-or-before the selected time (documented nearest-rule), with its index and timestamp labeled.
- When the cursor moves, the picture updates to the newly-indexed frame without desynchronizing from the cursor's selected time.
- If no picture exists at/near the selected time, the panel shows an explicit "no frame at this time" state rather than a stale image.
- The displayed picture is read from the VM-local mprr review-capture store (the cleanroom), not fetched over the coordination bus (LBA-REQ-009, ADR-0005).
Index pictures by run-relative timestamp so cursor→picture
resolution is O(log n) and deterministic. mprr's short-packet stream already
supplies this index as timingTicks64 (100 ns timing authority) keyed to
frameId/payloadDescriptorId; a live capture confirmed the resolve path
end-to-end (see experiments/mprr-live-capture/).
experiments/mprr-live-capture/evidence/dual-packet-correlation-receipt.json; experiments/mprr-capture-ring/verify-benchmark-panels.mjs; test/panels-render.mjs