Skip to content

LBA REQ 005

github-actions[bot] edited this page Nov 19, 2026 · 2 revisions

LBA-REQ-005: Time-indexed picture shown below the benchmark

Status

Proposed

Area

User Interface

Statement

Directly below the benchmark chart, the viewer shall display the captured picture indexed at the cursor's selected time, updating as the cursor moves.

Rationale

Acceptance Criteria

  • The picture shown is the frame whose timestamp is nearest at-or-before the selected time (documented nearest-rule), with its index and timestamp labeled.
  • When the cursor moves, the picture updates to the newly-indexed frame without desynchronizing from the cursor's selected time.
  • If no picture exists at/near the selected time, the panel shows an explicit "no frame at this time" state rather than a stale image.
  • The displayed picture is read from the VM-local mprr review-capture store (the cleanroom), not fetched over the coordination bus (LBA-REQ-009, ADR-0005).

Verification

Historical statement (no longer implemented)

Supersession

Change Guidance

Index pictures by run-relative timestamp so cursor→picture resolution is O(log n) and deterministic. mprr's short-packet stream already supplies this index as timingTicks64 (100 ns timing authority) keyed to frameId/payloadDescriptorId; a live capture confirmed the resolve path end-to-end (see experiments/mprr-live-capture/).

TestID

T-005

CodeRef

experiments/mprr-live-capture/evidence/dual-packet-correlation-receipt.json; experiments/mprr-capture-ring/verify-benchmark-panels.mjs; test/panels-render.mjs

RTM Status

Proven