Hi! I'm working with the SARA-R510M8S on the ESP-IDF platform. I'm looking to get a constant location from the GNSS module while also maintaining an MQTT connection over the cellular network. I've gotten each part working independently, but once I try to do both at once, I lose the first network (GNSS or Cellular) despite which network I bring up first. I've followed some of the steps mentioned in #155 and merged it with the MQTT example.
Essentially my problem is that I can't seem to keep both networks on at the same time. I've included the main part of my code below. Any thoughts? Thank you!
static const uDeviceCfg_t gDeviceCfg = {
.deviceType = U_DEVICE_TYPE_CELL,
.deviceCfg = {
.cfgCell = {
.moduleType = U_CFG_TEST_CELL_MODULE_TYPE,
.pSimPinCode = NULL,
.pinEnablePower = -1,
.pinPwrOn = -1,
.pinVInt = -1,
.pinDtrPowerSaving = -1},
},
.transportType = U_DEVICE_TRANSPORT_TYPE_UART,
.transportCfg = {
.cfgUart = {.uart = 2, .baudRate = U_CELL_UART_BAUD_RATE, .pinTxd = 21, .pinRxd = 19, .pinCts = -1, .pinRts = -1, .pPrefix = NULL},
},
};
// NETWORK configuration for cellular
static const uNetworkCfgCell_t gNetworkCfg = {
.type = U_NETWORK_TYPE_CELL,
.pApn = SIM_APN,
.timeoutSeconds = 6000,
};
// NETWORK configuration for GNSS
static const uNetworkCfgGnss_t gnssNetworkCfg = {
.type = U_NETWORK_TYPE_GNSS,
.moduleType = U_GNSS_MODULE_TYPE_M8,
.devicePinPwr = -1,
.devicePinDataReady = -1};
void init_modem(void) {
uPortInit();
uDeviceInit();
// Open the device
returnCode = uDeviceOpen(&gDeviceCfg, &devHandle);
uPortLog("Opened device with return code %d.\n", returnCode);
if (returnCode == 0)
{
uPortLog("Bringing up GNSS...\n");
if (uNetworkInterfaceUp(devHandle, U_NETWORK_TYPE_GNSS, &gnssNetworkCfg) == 0)
{
uPortLog("Starting continuous location.\n");
returnCode = uLocationGetContinuousStart(devHandle, U_GNSS_POS_STREAMED_PERIOD_DEFAULT_MS, U_LOCATION_TYPE_GNSS, NULL, NULL, gnssCallback);
if (returnCode != 0)
{
uPortLog("Unable to start continuous location!\n");
}
}
else
{
uPortLog("Unable to bring up GNSS!\n");
}
// Bring up the network interface
uPortLog("Bringing up the network...\n");
if (uNetworkInterfaceUp(devHandle, U_NETWORK_TYPE_CELL,
&gNetworkCfg) == 0)
{
pContext = pUMqttClientOpen(devHandle, NULL);
if (pContext != NULL)
{
uPortLog("Connecting to MQTT broker \"%s\"...\n", MY_BROKER_NAME);
if (uMqttClientConnect(pContext, &connection) == 0)
{
uMqttClientSetMessageCallback(pContext, messageIndicationCallback, (void *)&messagesAvailable);
uSecurityGetSerialNumber(devHandle, topic);
xTaskCreate(mqttRead_task, "mqttRead_task", 1024 * 4, NULL, 5, &mqttRead_taskHandle);
returnCode = 0;
uPortLog("Subscribing to topic \"%s\"...\n", topic);
if (uMqttClientSubscribe(pContext, topic, U_MQTT_QOS_AT_MOST_ONCE))
{
uPortLog("Publishing \"%s\" to topic \"%s\"...\n",
message, topic);
if (uMqttClientPublish(pContext, topic, message, sizeof(message) - 1, U_MQTT_QOS_AT_MOST_ONCE, false) == 0)
{
returnCode = 0;
}
else
{
uPortLog("Unable to publish our message \"%s\"!\n", message);
}
}
else
{
uPortLog("Unable to subscribe to topic \"%s\"!\n", topic);
}
}
else
{
uPortLog("Unable to connect to MQTT broker \"%s\"!\n", MY_BROKER_NAME);
}
}
else
{
uPortLog("Unable to create MQTT instance!\n");
}
}
else
{
uPortLog("Unable to bring up the network!\n");
}
}
else
{
uPortLog("Unable to bring up the device!\n");
}
}
Hi! I'm working with the SARA-R510M8S on the ESP-IDF platform. I'm looking to get a constant location from the GNSS module while also maintaining an MQTT connection over the cellular network. I've gotten each part working independently, but once I try to do both at once, I lose the first network (GNSS or Cellular) despite which network I bring up first. I've followed some of the steps mentioned in #155 and merged it with the MQTT example.