ADR-002: Slot Model

Status: Accepted · Date: 2026-05-08 · Scope: Planner engine, all scheduling layers


Context

The HSEM planner operates over a discretised time horizon. Every planning decision — charge, discharge, export, idle — must be assigned to a specific time interval with precise energy accounting. The data structure that represents one atomic time interval in the horizon is called a slot.

The slot model must satisfy several conflicting requirements:

  1. Deterministic energy accounting — Every slot must carry enough fields to independently verify energy balance (load = PV + battery + grid) without cross-referencing other slots.

  2. Flexible granularity — The planner supports 15-minute and 60-minute slot widths. The slot model must work identically at both resolutions.

  3. Layered recommendation assignment — Three independent layers (planner engine, EV labelling, runtime resolver) may assign or override a slot's recommendation. The slot must preserve this provenance.

  4. Multi-day horizon — Horizons span up to 48 hours (192 × 15-min slots). The slot model must handle missing future-day data gracefully without crashing.

  5. Planner independence — The slot model lives in the pure-Python planner layer (no Home Assistant imports). It must be fully serialisable for test assertions and debug logging.


Decision

We adopt an explicit per-slot record model. Every slot in the horizon is a PlannedSlot dataclass (or equivalent typed dict) with the following field groups:

Temporal identity

  • start_time / end_time — timezone-aware datetime range
  • duration_hours — cached float for power→energy conversion
  • slot_index — ordinal position in the horizon [0..n-1]

Forecast data (immutable after population)

  • estimated_house_consumption_kwh — weighted historical average
  • solcast_pv_estimate_kwh — Solcast forecast (decayed for future days)
  • import_price_kwh / export_price_kwh — full currency/kWh rate
  • tariff_cost_kwh — optional grid tariff
  • ev_planned_load_kwh — extra EV AC load not in house load
  • ev_accounted_load_kwh — EV AC load already in house load
  • ev_total_planned_load_kwh — sum of both EV fields

Planning decisions (mutable during pipeline)

  • recommendationRecommendations enum value (or None)
  • batteries_charged_kwh — energy stored by charging in this slot
  • batteries_discharged_kwh — energy removed by discharging in this slot
  • grid_import_kwh / grid_export_kwh — grid energy flows
  • pv_used_kwh — PV energy consumed locally (includes battery/PV/EV)
  • estimated_battery_soc_before_kwh / estimated_battery_soc_after_kwh
  • estimated_battery_soc_before_pct / estimated_battery_soc_after_pct

Derived / diagnostic

  • estimated_net_consumption_kwhhouse_load + ev_planned - pv
  • time_passedTrue if slot's end time is in the past
  • is_planned_load_slotTrue if EV load is scheduled here

Key design rules

1. No nullable energy fields at planner output

Every energy field is 0.0 for slots that do not participate (past slots, idle recommendations). This eliminates the need for null guards in cost calculators and SoC simulation.

2. Recommendation is the sole control signal

The SoC simulator reads only the slot's recommendation to decide energy flows. No other field drives behaviour — this keeps the simulation deterministic and testable.

3. Past-slot sentinel

After time passes, recommendation is set to time_passed, all energy fields are zeroed, and estimated_battery_soc_after_kwh is set to 0.0. The cost function skips these slots entirely.

4. Dedicated fields, not derived

estimated_net_consumption_kwh is populated explicitly (with PV confidence decay applied) rather than computed on-the-fly. This ensures consistency between the planner that schedules around it and the sensors that display it.

5. Energy units only

All power limits are converted to per-slot energy caps at the planner boundary. The slot model never stores kW values — only kWh.


Consequences

Positive

  1. Auditability — Every energy flow is independently recorded. Two planners processing the same input produce byte-identical slot arrays.

  2. Testability — A slot array can be constructed manually in a unit test and fed directly into the cost function or SoC simulator without HA infrastructure.

  3. Layered safety — The mutable recommendation field allows three independent layers to assign and override without corrupting other fields.

  4. Granularity independence — All formulas use duration_hours as a multiplier. The same slot population code works for 15-min and 60-min slots unchanged.

  5. Diagnostically rich — Every Home Assistant sensor attribute is populated from slot fields with no additional computation.

Negative

  1. Field count — A PlannedSlot has ~20 fields, which is large relative to a simpler (start, end, energy) tuple. This increases memory per slot and serialisation volume.

  2. Population cost — Building the full slot array requires iterating all fields for every slot. For 192 × 15-min slots this is negligible (< 1 ms), but the code is more verbose than a lazy-evaluation approach.

  3. Duplication of time series — Several fields (price, PV, load) are repeated per slot instead of stored once in a shared time series. This is acceptable for n ≤ 192 slots but would not scale to thousands.

  4. Mutation risk — Because slots are mutable, a bug in one pipeline step can corrupt fields that other steps depend on. We mitigate this by strictly ordering slot population before SoC simulation, and simulation before cost scoring.


Alternatives Considered

A. Lazy / index-based model

Store all time-series data in parallel arrays (price[0..n-1], load[0..n-1], etc.) and compute slot views on demand.

Rejected because:

  • Each pipeline step (schedule, simulate, score) would need to carry the full index around, making function signatures fragile.
  • Derived fields (net consumption) would be recomputed in every step, risking inconsistency with PV confidence decay.
  • Test readability suffers — slot-level assertions require array indexing.

B. Event-sourced state machine

Model the battery as a state machine and slots as transitions. Reconstruct the slot array from the transition log.

Rejected because:

  • Over-engineered for the current requirements. The slot count (≤ 192) makes reconstruction overhead irrelevant.
  • Auditability suffers — there is no single "slot n" object to inspect in a debugger or log.
  • Three-layer recommendation assignment becomes complex when state transitions are first-class objects.

C. Single energy model per slot

Store only net_kwh = PV - load per slot and derive all battery/grid flows from that single number.

Rejected because:

  • Loss of information — you cannot distinguish "grid import for battery" from "grid import for house" after simplification.
  • Terminal SoC accounting requires knowing battery energy removed, not just net.
  • Diagnostic sensor values (battery charged/discharged per slot) would require reverse computation, which is fragile and imprecise.

Related

  • ADR-001: Planner Extraction (slot model is the core data type passing through the extracted planner boundary)
  • ADR-003: Cost Scoring (cost function reads every energy field from the slot)
  • docs/planner-spec.md — Slot definition in Core concepts
  • models/planner_outputs.pyPlannedSlot implementation