Skip to content
JamesNewton edited this page Jul 22, 2019 · 12 revisions

Errors that occur on Dexter are communicated in the next returned packet.

  • Most oplets will return a status with a standard error code (see list below)
  • Read From Robot and Write To Robot deal with file IO and so return the standard Linux error numbers
  • The Monitor can override any of the above, replacing the status error with a number in the 600-699 range. In that case, it is possible that a prior error may be overwritten. E.g. If a monitor error occurs during a Read From Robot or Write To Robot which also generated an error, that error would be lost. Any such operation should be restarted once the monitor error is resolved.
No Description
0 No error
1 Unknown Most often returned when the requested oplet or sub command is not known. This is most likely to occur because the firmware on the robot is out of date, and it should be updated.
2 Bad Request The request was incorrectly formatted. In practice, this means there was no ';' at the end of the last socket data. Any other malformation is unlikely to be detected.
3? Firmware - Gateware Mismatch The DexRun.c firmware and xillydemo.bit gateware files do not match. See Issue 68 for more information. Note: This error code is not yet implemented
665 Boundary error A joint was commanded to move past the boundary set for it, Read the errors.log file for details. There are high and low boundary settings for each joint: J#Boundry(High
666 Monitor error Raw encoder position or velocity exceeded, Read the errors.log file for details. If the error was velocity related, the robot will be switched into open loop mode from any closed loop mode under the assumption that the cause is a bad encoder.