HOMEd

English · Русский

OTGateway connects to HOMEd through MQTT and the HOMEd Custom service. The device template adds heating and DHW controls, controller settings, states and sensor readings.

The template supports current OTGateway firmware with separate MQTT topics for each value. It uses metric units: °C, L/min, bar and kW.

Connect

  1. Connect HOMEd Custom and OTGateway to the same MQTT broker. In OTGateway, open Settings → MQTT settings, enable MQTT and save.
  2. Download the import file: otgateway.json.
  3. Replace every occurrence of <prefix> with the prefix from your OTGateway MQTT settings, including availabilityTopic. Use unique id and name values if adding several devices.
  4. Open HOMEd Web in a desktop browser, select the appropriate Custom service, click Import and select the edited file. Import adds the device immediately. Keep real: true to enable bindings.
  5. Wait at least 30 seconds after OTGateway connects to the broker, then check the states and readings in HOMEd.

The downloaded file describes one device. To edit the HOMEd Custom database manually, stop the service and back up its database. Add the full template object to the existing devices array, save the file and start the service. The default database path is /opt/homed-custom/database.json; the service configuration may specify another path. Preserve the other devices in the array.

Available functions

Group Controls and readings
Heating Enable, target, flow temperature limits, Turbo and hysteresis
DHW Enable, target and temperature limits
PID Enable, gains, calculation interval, output limits and deadband
Weather compensation Enable, heating curve slope, exponent, shift and indoor temperature correction
State OpenTherm connection, circuit and cooling activity, flame, heating blocking, protections, emergency mode, pump and cascade control
Diagnostics Fault and diagnostic flags, codes and reset buttons, ESP32 uptime and restart
Readings Default sensors, indoor sensor connection, combined indoor and outdoor temperatures, calculated heating setpoint

Protection thresholds, modulation caps, the emergency target and sensor aggregation are configured in the OTGateway web interface.

Device availability uses <prefix>/status: online means the ESP32 is connected to the broker. The separate openthermConnectionState indicator shows the connection to the Slave device. Sensor and circuit functions also depend on support from the Slave device.

heatingEnabled shows the saved setting, heatingRequested shows the circuit permission calculated by OTGateway, and heatingActive shows the activity reported by the Slave device. The corresponding DHW properties are dhwEnabled, dhwRequested and dhwActive.

Heating and DHW control

HOMEd property Purpose
heatingEnabled Enable the heating circuit
heatingTargetTemperature Indoor target with PID, weather compensation or the Slave device's native weather compensation; otherwise the flow temperature target
heatingMinTemperature Lower heating flow temperature limit
heatingMaxTemperature Upper heating flow temperature limit
heatingTurbo Enable Turbo for PID or weather compensation
heatingHysteresisEnabled Enable heating hysteresis
heatingHysteresis Indoor temperature deviation used to pause and resume heating
dhwEnabled Enable the DHW circuit
dhwTargetTemperature DHW target temperature
dhwMinTemperature Lower DHW target limit
dhwMaxTemperature Upper DHW target limit
pidEnabled Enable PID
pidPFactor Proportional gain
pidIFactor Integral gain
pidDFactor Derivative gain
pidDt PID calculation interval, seconds
pidMinTemperature Lower PID output limit
pidMaxTemperature Upper PID output limit
pidDeadbandEnabled Enable separate gain multipliers near the indoor target
pidDeadbandPMultiplier Proportional gain multiplier inside the deadband
pidDeadbandIMultiplier Integral gain multiplier inside the deadband
pidDeadbandDMultiplier Derivative gain multiplier inside the deadband
pidDeadbandThresholdHigh Deadband width above the indoor target
pidDeadbandThresholdLow Deadband width below the indoor target
equithermEnabled Enable weather compensation
equithermSlope Heating curve slope
equithermExponent Heating curve exponent
equithermShift Heating curve temperature offset
equithermTargetDiffFactor Correction factor for the difference between the indoor target and measured temperature
heatingSetpointTemperature Calculated flow temperature setpoint, read only

OTGateway validates changes and publishes the accepted settings back to HOMEd. Circuit temperature limits also respect the Slave device's limits.

pidMinTemperature and pidMaxTemperature use whole numbers. With PID alone, they limit the flow temperature; with weather compensation, they limit the correction to the heating curve. A negative lower limit applies only with weather compensation.

Controller settings are described in the heating documentation. Protection thresholds, modulation caps, the emergency target and sensor aggregation are configured in the OTGateway web interface.

Important

If you switch OTGateway to imperial units, adapt the template's units, numeric ranges and steps. Changing a °C label to °F alone is insufficient.

Sensors

Readings and sensor connections

The template uses the default OTGateway sensor names.

OTGateway sensor HOMEd reading Enabled by default
Outdoor temp outdoorTemperature No
Indoor temp indoorTemperature No
Heating temp heatingCurrentTemperature Yes
Heating return temp heatingReturnTemperature Yes
Heating setpoint temp heatingSetpointTemperature Yes
DHW temp dhwCurrentTemperature Yes
DHW flow rate dhwFlowRate Yes
Exhaust temp exhaustTemperature Yes
Pressure pressure Yes
Modulation level modulationLevel Yes
Power power Yes

heatingSetpointTemperature reads OTGateway's calculated setpoint directly and does not depend on the named Heating setpoint temp sensor being enabled.

For example, indoorTemperature = 21.5 and indoorTemperatureConnected = true mean that the indoor sensor is connected and reads 21.5 °C. When indoorTemperatureConnected = false, HOMEd may retain the last number. The other sensors' readings and connection states can be viewed on the OTGateway Dashboard. An OpenTherm connection does not guarantee that the Slave device supports or provides every measurement.

Indoor temp and Outdoor temp are disabled by default. In the OTGateway sensor settings, enable the sensor and select its source and purpose. For example, for a room DS18B20, select Dallas, specify the GPIO and choose Indoor temperature. After saving, check its reading and connection on the OTGateway Dashboard and in HOMEd.

Zero modulation is valid while the flame is on. flameState shows burner operation.

Temperatures used for control

When several sensors share a purpose, OTGateway combines their readings. The template shows the indoor and outdoor temperatures used for heating control separately from individual sensor readings.

HOMEd property Reading
heatingIndoorTemperature Indoor temperature used for heating control
heatingOutdoorTemperature Outdoor temperature used for heating control

For example, 2 connected room sensors read 20 and 22 °C. If both have the Indoor temperature purpose, the result in heatingIndoorTemperature depends on the aggregation method selected in the OTGateway web interface under Heating settings:

Selection Result
mean 21 °C
minimum 20 °C
maximum 22 °C

The outdoor temperature aggregation method is set separately in the same settings.

Only connected sensors contribute to the calculation. If no sources with the required purpose remain, the combined temperature becomes 0. The participating sensors' connection states are shown in OTGateway. The number 0 alone cannot distinguish a missing source from an actual reading.

Rename a sensor or change its type

A sensor's MQTT address depends on its name. For example, renaming Indoor temp to Living room changes its slug from indoor_temp to living_room. Update 2 fields in the HOMEd device definition's bindings object:

Property New inTopic value
indoorTemperature <prefix>/sensors/living_room/value
indoorTemperatureConnected <prefix>/sensors/living_room/connected

You can keep the HOMEd property names so existing automations continue to use indoorTemperature. OTGateway reports the current slug in its sensor REST API.

Dallas, NTC, OpenTherm and MANUAL sensors publish temperature at /value. Bluetooth, DHT11 and DHT22 sensors use /temperature. If Living room uses Bluetooth, set indoorTemperature to read <prefix>/sensors/living_room/temperature. The connection topic stays <prefix>/sensors/living_room/connected.

Save the updated definition in HOMEd and compare the reading with the OTGateway Dashboard. The combined heatingIndoorTemperature property continues to work after a source is renamed because it depends on the sensor's purpose.

Humidity from a Bluetooth or DHT sensor

Bluetooth, DHT11 and DHT22 sensors also provide humidity. For example, to add humidity from Living room to the HOMEd device definition, append indoorHumidity to the existing exposes array and add entries with the same name to options and bindings. Only the new entries are shown below:

{
  "exposes": ["indoorHumidity"],
  "options": {
    "indoorHumidity": {
      "type": "sensor",
      "class": "humidity",
      "state": "measurement",
      "unit": "%",
      "round": 1
    }
  },
  "bindings": {
    "indoorHumidity": {
      "inTopic": "<prefix>/sensors/living_room/humidity",
      "inPattern": "{{ value if value is number else _NULL_ }}"
    }
  }
}

Preserve the device's other properties. The same indoorTemperatureConnected indicator shows the connection to the humidity source.

Supply a temperature from HOMEd to OTGateway

This method applies when the indoor or outdoor sensor is already connected to HOMEd, for example through Zigbee. This example uses the default Indoor temp name; a renamed sensor uses its new slug.

  1. In the OTGateway sensor settings, select Indoor temp.
  2. Select Manual via MQTT/API, choose the Indoor temperature purpose, enable the sensor and save. The Temperature purpose displays a number but does not include it in heating control.
  3. Configure HOMEd to send the source temperature to <prefix>/sensors/indoor_temp/value/set. Send only a number in OTGateway's units, such as 21.5, with retain disabled.
  4. Repeat the transmission every 1–5 minutes, including while the temperature is unchanged. After 10 minutes without updates, OTGateway considers a MANUAL sensor disconnected.
  5. After transmission, check indoorTemperature = 21.5, indoorTemperatureConnected = true and the combined heatingIndoorTemperature. If there is only one indoor source, the combined temperature should match it.

For example, a Zigbee sensor in HOMEd has the address zigbee/roomThermometer and the temperature property. The following automation sends its temperature whenever the reading changes and at 1-minute intervals. It checks service and sensor availability, a numeric temperature and the time of the sensor's last message.

{
  "active": true,
  "mode": "single",
  "name": "Room temperature to OTGateway",
  "triggers": [
    {
      "type": "property",
      "endpoint": "zigbee/roomThermometer",
      "property": "temperature",
      "updates": true
    },
    {
      "type": "interval",
      "interval": 1
    }
  ],
  "conditions": [
    {
      "type": "mqtt",
      "topic": "homed/service/zigbee",
      "property": "status",
      "equals": "online"
    },
    {
      "type": "mqtt",
      "topic": "homed/device/zigbee/roomThermometer",
      "property": "status",
      "equals": "online"
    },
    {
      "type": "pattern",
      "pattern": "{{ true if {{ property | zigbee/roomThermometer | temperature }} is number else false }}",
      "equals": true
    },
    {
      "type": "pattern",
      "pattern": "{{ true if {{ mqtt | homed/device/zigbee/roomThermometer | lastSeen }} is number else false }}",
      "equals": true
    },
    {
      "type": "pattern",
      "pattern": "[[ {{ timestamp }} - {{ mqtt | homed/device/zigbee/roomThermometer | lastSeen }} ]]",
      "between": [0, 300]
    }
  ],
  "actions": [
    {
      "type": "mqtt",
      "topic": "<prefix>/sensors/indoor_temp/value/set",
      "message": "{{ property | zigbee/roomThermometer | temperature }}",
      "retain": false
    }
  ]
}

Replace <prefix> with the OTGateway prefix and every source address with your sensor's address. The example uses the default HOMEd prefix homed and the zigbee service without an instance name. The device state topic must match your HOMEd MQTT topic structure, including the use of device IDs or names.

Save the example as a JSON file. In HOMEd Web, select Automation → Import, open the file and save the automation. This requires the HOMEd Automation service. In this example, the source and OTGateway use °C; different units require temperature conversion.

The 300 threshold means 5 minutes since the source's last message. Its value depends on the sensor's update interval. lastSeen reflects communication with the device, so the example assumes a source that regularly sends current temperature readings. If the source becomes unavailable or stops reporting, forwarding stops; 10 minutes after the last transmission, OTGateway marks the MANUAL sensor as disconnected. The automation fields are described in the HOMEd documentation.

Outdoor temperature uses Outdoor temp, the Outdoor temperature purpose and the <prefix>/sensors/outdoor_temp/value/set topic. Several HOMEd sources require a separate OTGateway MANUAL sensor for each source: sending different readings to one slot preserves only the last one.

Diagnostics

The faultReset and diagReset buttons request a reset. OTGateway processes the request when the Slave device is in a suitable state. The result appears in faultState, diagState, faultCode and diagCode after the next update. Code 0 is preserved as a number.

The restart button schedules an ESP32 restart in 15 seconds.

Migrate an existing integration

We recommend deleting the old template completely and adding the new one. Keeping the existing device's id and name is recommended but optional.