MQTT
English · Русский
MQTT provides access to OTGateway and sensor state, settings and commands. OTGateway receives commands through the broker, validates them and uses them when controlling the OpenTherm Slave device.
The prefix is set under MQTT settings and represented by <prefix> in the tables. The default is otgateway_ followed by the ESP32 chip ID in hexadecimal.
MQTT can be enabled under Settings → MQTT settings, where the broker address, port and credentials are also set. The publish interval is 3–60 seconds, with a default of 5 seconds.
Home Assistant Discovery enables entity discovery in Home Assistant. Its discovery prefix defaults to homeassistant and is separate from the device prefix. See Home Assistant setup.
The discovery prefix accepts 1–32 bytes without +, # or a NUL character. Nested prefixes containing / are allowed.
| Topic | Access | Meaning |
|---|---|---|
<prefix>/status |
RO | ESP's connection to the broker, online or offline
|
<prefix>/state/master/<path> |
RO | Circuit states reported by OTGateway, calculated setpoints and combined sensor readings |
<prefix>/state/slave/<path> |
RO | OpenTherm link to the Slave device, its status, limits and diagnostics |
<prefix>/settings/<path> |
RO | Current value of a writable setting |
<prefix>/settings/<path>/set |
WO | Request a new value for that setting |
<prefix>/sensors/<slug>/<field> |
RO | Connection status or measurement for one configured sensor |
<prefix>/sensors/<slug>/value/set |
WO | Supply a measurement for an enabled MANUAL sensor |
<prefix>/actions/<action>/set |
WO | Request a restart, fault reset or diagnostic reset |
RO is a topic you subscribe to for readings. WO is a topic you publish commands to. RW means you can read and change a value. Reading and writing use separate topics, as shown in the table.
Command payloads are plain text. Booleans are written as true or false, and numbers without quotes or unit symbols, for example 21.5. Numbers must be finite and use the units selected in OTGateway. The command topic limit is 128 bytes including the prefix, and the payload limit is 64 bytes.
All state topics are RO and refresh at the configured MQTT publish interval
(3–60 seconds, default 5). <prefix>/status reports OTGateway availability.
Its values are online and offline.
Note
Firmware publications use QoS 0. The broker last will announces offline at
QoS 1. Fresh telemetry starts at least 30 seconds after the ESP reconnects.
Retained values from the previous connection can arrive sooner.
| State topic (RO) | Payload | Meaning |
|---|---|---|
<prefix>/state/master/heating/enabled |
Boolean | OTGateway has enabled the heating circuit |
<prefix>/state/master/heating/blocking |
Boolean | Indoor temperature hysteresis is blocking heating |
<prefix>/state/master/heating/smart_control |
Boolean |
true means the heating target is indoor temperature (PID, Equitherm or the Slave device's native weather compensation). false means the target is heating fluid temperature. |
<prefix>/state/master/heating/overheat |
Boolean | Heating overheat protection is active |
<prefix>/state/master/heating/freezing |
Boolean | Freeze protection is active |
<prefix>/state/master/heating/target_temp |
Temperature | Requested heating target |
<prefix>/state/master/heating/setpoint_temp |
Temperature | Setpoint calculated by OTGateway |
<prefix>/state/master/heating/current_temp |
Temperature | Average heating flow temperature |
<prefix>/state/master/heating/return_temp |
Temperature | Average heating return temperature |
<prefix>/state/master/heating/indoor_temp |
Temperature | Combined indoor sensor reading |
<prefix>/state/master/heating/outdoor_temp |
Temperature | Combined outdoor sensor reading |
<prefix>/state/master/heating/min_temp |
Temperature | Current lower limit for the heating target |
<prefix>/state/master/heating/max_temp |
Temperature | Current upper limit for the heating target |
<prefix>/state/master/dhw/enabled |
Boolean | OTGateway has enabled the DHW circuit |
<prefix>/state/master/dhw/overheat |
Boolean | DHW overheat protection is active |
<prefix>/state/master/dhw/target_temp |
Temperature | Requested DHW target |
<prefix>/state/master/dhw/current_temp |
Temperature | Average DHW temperature |
<prefix>/state/master/dhw/return_temp |
Temperature | Average DHW return temperature |
<prefix>/state/master/dhw/min_temp |
Temperature | Configured lower DHW target limit |
<prefix>/state/master/dhw/max_temp |
Temperature | Configured upper DHW target limit |
| State topic (RO) | Payload | Meaning |
|---|---|---|
<prefix>/state/master/network/connected |
Boolean | ESP32 has a Wi-Fi or Ethernet network connection |
<prefix>/state/master/network/connection_type |
Text |
wifi, ethernet, wifi-ap or none, for the currently selected network interface |
<prefix>/state/master/network/rssi |
dBm | Wi-Fi signal strength; interpret only when connection_type is wifi
|
<prefix>/state/master/emergency/state |
Boolean | Emergency mode is active |
<prefix>/state/master/ext_pump/state |
Boolean | External pump is on |
<prefix>/state/master/cascade_control/input |
Boolean | Cascade control input state |
<prefix>/state/master/cascade_control/output |
Boolean | Cascade control output state |
<prefix>/state/master/uptime |
Seconds | Time since ESP32 startup |
| State topic (RO) | Payload | Meaning |
|---|---|---|
<prefix>/state/slave/connected |
Boolean | OTGateway is receiving OpenTherm replies from the Slave device |
<prefix>/state/slave/flame |
Boolean | Slave device reports flame on |
<prefix>/state/slave/heating/active |
Boolean | Slave device reports central heating active |
<prefix>/state/slave/heating/min_temp |
Temperature | Slave device's lower heating temperature bound |
<prefix>/state/slave/heating/max_temp |
Temperature | Slave device's upper heating temperature bound |
<prefix>/state/slave/dhw/active |
Boolean | Slave device reports DHW active |
<prefix>/state/slave/dhw/min_temp |
Temperature | Slave device's lower DHW temperature bound |
<prefix>/state/slave/dhw/max_temp |
Temperature | Slave device's upper DHW temperature bound |
<prefix>/state/slave/cooling/active |
Boolean | Slave device reports cooling active |
<prefix>/state/slave/cooling/setpoint |
% | Cooling control signal returned by the Slave device |
<prefix>/state/slave/modulation/min |
% | Minimum modulation reported by the Slave device |
<prefix>/state/slave/modulation/max |
% | Upper modulation limit returned by the Slave device when OTGateway writes the setting |
<prefix>/state/slave/power/min |
kW | Minimum power calculated from the reported maximum capacity and minimum modulation |
<prefix>/state/slave/power/max |
kW | Maximum capacity reported by the Slave device |
| State topic (RO) | Payload | Meaning |
|---|---|---|
<prefix>/state/slave/member_id |
Integer | Member ID reported by the Slave device |
<prefix>/state/slave/flags |
Integer | Slave device configuration flags, as a byte |
<prefix>/state/slave/type |
Integer | Slave device type byte |
<prefix>/state/slave/app_version |
Integer | Slave device application version |
<prefix>/state/slave/protocol_version |
Number | OpenTherm protocol version |
<prefix>/state/slave/fault/active |
Boolean | Fault flag |
<prefix>/state/slave/fault/code |
Integer | Manufacturer's fault code |
<prefix>/state/slave/fault/available |
Boolean | OpenTherm is connected and a fault is active |
<prefix>/state/slave/diag/active |
Boolean | Diagnostic flag |
<prefix>/state/slave/diag/code |
Integer | Manufacturer's diagnostic code |
<prefix>/state/slave/diag/available |
Boolean | Diagnostic flag is set, or a fault is active with OpenTherm connected |
Settings support reading and writing (RW). The tables list read topics. Writing uses the same topic with the /set suffix. For example, the DHW target is read from <prefix>/settings/dhw/target, and a new temperature is sent to <prefix>/settings/dhw/target/set.
OTGateway publishes accepted settings on their read topics after a change and every 10 MQTT publish intervals.
If a heating, DHW or emergency target is outside the allowed range, OTGateway substitutes the default for that mode and bounds it by the current limits.
You can configure the network, OpenTherm and sensors in the web interface. Programmatic changes to these settings are described in the REST API.
| Read topic (RO) | Payload | What it controls |
|---|---|---|
<prefix>/settings/heating/enabled |
Boolean | Allow central heating |
<prefix>/settings/heating/target |
Temperature | Requested indoor or heating fluid temperature, depending on regulation mode |
<prefix>/settings/heating/min_temp |
Temperature | Minimum flow temperature |
<prefix>/settings/heating/max_temp |
Temperature | Maximum flow temperature |
<prefix>/settings/heating/max_modulation |
1–100% | Upper limit on relative modulation for heating |
<prefix>/settings/heating/turbo |
Boolean | Enable turbo heating with PID or Equitherm |
<prefix>/settings/heating/turbo_factor |
1.5–10 | Strength of the indoor temperature correction in turbo mode |
<prefix>/settings/heating/hysteresis/enabled |
Boolean | Use indoor temperature hysteresis to pause and resume heating |
<prefix>/settings/heating/hysteresis/value |
0–15 | Distance on either side of the indoor target at which heating switches |
<prefix>/settings/heating/indoor_temp_avg_type |
0 / 1 / 2 | Combine indoor readings using mean / minimum / maximum |
<prefix>/settings/heating/outdoor_temp_avg_type |
0 / 1 / 2 | Combine outdoor readings using mean / minimum / maximum |
<prefix>/settings/heating/overheat_protection/high_temp |
Temperature | Temperature that triggers heating overheat protection. Writing 0 sets the upper threshold to low_temp. |
<prefix>/settings/heating/overheat_protection/low_temp |
Temperature | Temperature that clears heating overheat protection. A value of 0 disables this protection. |
<prefix>/settings/heating/freeze_protection/low_temp |
Temperature | Trigger freeze protection |
<prefix>/settings/heating/freeze_protection/high_temp |
Temperature | Clear freeze protection |
| Read topic (RO) | Value | Controls |
|---|---|---|
<prefix>/settings/emergency/target |
Temperature | Target temperature in emergency mode |
| Read topic (RO) | Payload | What it controls |
|---|---|---|
<prefix>/settings/dhw/enabled |
Boolean | Allow domestic hot water heating |
<prefix>/settings/dhw/target |
Temperature | DHW target temperature |
<prefix>/settings/dhw/min_temp |
Temperature | Lower DHW target limit |
<prefix>/settings/dhw/max_temp |
Temperature | Upper DHW target limit |
<prefix>/settings/dhw/max_modulation |
1–100% | Upper limit on relative modulation for DHW |
<prefix>/settings/dhw/overheat_protection/high_temp |
Temperature | Temperature that triggers DHW overheat protection. Writing 0 sets the upper threshold to low_temp. |
<prefix>/settings/dhw/overheat_protection/low_temp |
Temperature | Temperature that clears DHW overheat protection. A value of 0 disables this protection. |
| Read topic (RO) | Payload | What it controls |
|---|---|---|
<prefix>/settings/pid/enabled |
Boolean | Enable PID control |
<prefix>/settings/pid/p_factor |
0 < value ≤ 1000 | Proportional gain |
<prefix>/settings/pid/i_factor |
0–100 | Integral gain |
<prefix>/settings/pid/d_factor |
0–100000 | Derivative gain |
<prefix>/settings/pid/dt |
30–1800 s | Time between PID calculations, in whole seconds |
<prefix>/settings/pid/min_temp |
Number | Lower PID output limit |
<prefix>/settings/pid/max_temp |
Number | Upper PID output limit |
<prefix>/settings/pid/deadband/enabled |
Boolean | Use separate gains near the indoor target |
<prefix>/settings/pid/deadband/threshold_high |
0–5 | Width of the deadband above the target |
<prefix>/settings/pid/deadband/threshold_low |
0–5 | Width of the deadband below the target |
<prefix>/settings/pid/deadband/p_multiplier |
0–1 | Multiply proportional gain inside the deadband |
<prefix>/settings/pid/deadband/i_multiplier |
0–1 | Multiply integral gain inside the deadband |
<prefix>/settings/pid/deadband/d_multiplier |
0–1 | Multiply derivative gain inside the deadband |
| Read topic (RO) | Payload | What it controls |
|---|---|---|
<prefix>/settings/equitherm/enabled |
Boolean | Enable weather compensation |
<prefix>/settings/equitherm/slope |
0.001–10 | Slope of the heating curve |
<prefix>/settings/equitherm/exponent |
0.01 < value ≤ 2 | Curvature of the heating curve |
<prefix>/settings/equitherm/shift |
−15 to +15 | Offset applied to the heating curve |
<prefix>/settings/equitherm/target_diff_factor |
0–10 | Strength of the correction for the difference between the indoor target and the indoor reading |
Metric temperatures use °C, DHW flow uses L/min and pressure uses bar. In the imperial system these are °F, US gal/min and psi. Power is always in kW and modulation is a percentage. A setting write contains only the number.
Hysteresis, PID deadband and Equitherm shift keep their numeric values when units change. Standalone PID limits set the flow temperature range. With Equitherm, they limit the correction to the heating curve.
Action topics are WO. A true payload with retain off requests the action.
false takes no action. The corresponding status can be checked after the next update.
| Command topic (WO) | What it does | Where to check the result |
|---|---|---|
<prefix>/actions/restart/set |
Schedules an ESP32 restart in 15 seconds |
<prefix>/state/master/uptime starts again after the restart |
<prefix>/actions/reset_fault/set |
Queues a fault reset. OTGateway sends it when the Slave device is ready and reports an active fault |
<prefix>/state/slave/fault/active and <prefix>/state/slave/fault/code
|
<prefix>/actions/reset_diagnostic/set |
Queues a diagnostic reset. OTGateway sends it when the Slave device is ready and reports an active diagnostic flag |
<prefix>/state/slave/diag/active and <prefix>/state/slave/diag/code
|
A sensor topic uses the slug derived from its name. For example, Heating return temp becomes heating_return_temp. The current slug is available through the sensor REST API. After a sensor is renamed, its subscriptions and the topic used to supply readings use the new slug.
Readings are published for enabled sensors with a name, type and purpose.
| Topic | Access | Applies to | Payload |
|---|---|---|---|
<prefix>/sensors/<slug>/connected |
RO | All publishing sensors |
true or false. A disconnected sensor may retain its last measurement |
<prefix>/sensors/<slug>/value |
RO | OpenTherm, OTGateway heating setpoint, Dallas, NTC, MANUAL | Primary measurement in the sensor's units |
<prefix>/sensors/<slug>/temperature |
RO | Bluetooth, DHT11, DHT22 | °C or °F |
<prefix>/sensors/<slug>/humidity |
RO | Bluetooth, DHT11, DHT22 | Relative humidity, % |
<prefix>/sensors/<slug>/battery |
RO | Bluetooth | Battery level, % |
<prefix>/sensors/<slug>/rssi |
RO | Bluetooth | Radio signal strength, dBm |
<prefix>/sensors/<slug>/signal_quality |
RO | Bluetooth, Dallas, DHT11, DHT22 | Signal quality, 0–100% |
<prefix>/sensors/<slug>/value/set |
WO | Enabled MANUAL sensors only | Reading in the units for the sensor’s purpose. Zero is valid. OTGateway stores the number directly, without calibration or filtering |
Sensor readings refresh on change and about every 5 minutes while unchanged.
The standard build supports up to 20 sensors. The table gives the default names and topics for IDs 0–10. IDs 11–19 are available for additional sensors.
Each sensor in the table also publishes connected alongside value.
The Dallas indoor sensor additionally publishes
<prefix>/sensors/indoor_temp/signal_quality when enabled.
| ID | Default name | Measurement topic (RO) | Unit | Enabled by default |
|---|---|---|---|---|
| 0 | Outdoor temp | <prefix>/sensors/outdoor_temp/value |
°C or °F | No |
| 1 | Indoor temp | <prefix>/sensors/indoor_temp/value |
°C or °F | No |
| 2 | Heating temp | <prefix>/sensors/heating_temp/value |
°C or °F | Yes |
| 3 | Heating return temp | <prefix>/sensors/heating_return_temp/value |
°C or °F | Yes |
| 4 | Heating setpoint temp | <prefix>/sensors/heating_setpoint_temp/value |
°C or °F | Yes |
| 5 | DHW temp | <prefix>/sensors/dhw_temp/value |
°C or °F | Yes |
| 6 | DHW flow rate | <prefix>/sensors/dhw_flow_rate/value |
L/min or US gal/min | Yes |
| 7 | Exhaust temp | <prefix>/sensors/exhaust_temp/value |
°C or °F | Yes |
| 8 | Pressure | <prefix>/sensors/pressure/value |
bar or psi | Yes |
| 9 | Modulation level | <prefix>/sensors/modulation_level/value |
% | Yes |
| 10 | Power | <prefix>/sensors/power/value |
kW | Yes |
OTGateway calculates the heating setpoint and estimates power from modulation reported by the Slave device and the configured power range.
The other measurements enabled by default depend on what the Slave device reports. <prefix>/state/slave/flame shows whether the burner is firing.
Zero modulation is valid while the flame is on.
The commands use broker.domain as a placeholder for your broker address and otgateway_abcdef for the device prefix.
This example sets a flow temperature of 50 °C. The published data lets you check the accepted setting, calculated setpoint and actual operation of the Slave device.
flowchart TD
client["Your MQTT client"]
device["OTGateway on ESP32"]
slave["OpenTherm Slave device"]
client -->|"Set target to 50 °C"| device
device -->|"Request 50 °C flow"| slave
slave -->|"Heating active, flow at 46.5 °C"| device
device -->|"Target 50 °C, measured flow 46.5 °C"| client
1. Check both connections. Open a monitor in one terminal. The device
publishes online on status when connected to the broker. Look for true on
state/slave/connected as well before interpreting data from the Slave device.
mosquitto_sub -h broker.domain -v \
-t 'otgateway_abcdef/status' -t 'otgateway_abcdef/state/slave/connected' \
-t 'otgateway_abcdef/settings/heating/target' \
-t 'otgateway_abcdef/state/master/heating/+' \
-t 'otgateway_abcdef/state/slave/heating/active' \
-t 'otgateway_abcdef/state/slave/flame' -t 'otgateway_abcdef/sensors/heating_temp/+'2. Request a target. In the first terminal, find smart_control, min_temp
and max_temp under state/master/heating. With smart_control = true, send
the desired indoor temperature. In this example smart_control = false, so the
command sets the heating fluid temperature. If you use metric units and the
50 °C you want is within the displayed limits, send the command from a second terminal.
mosquitto_pub -h broker.domain -t 'otgateway_abcdef/settings/heating/target/set' -m '50'3. Compare the request and the result in the first terminal. Each topic updates independently.
| What to check | Topic | Example value |
|---|---|---|
| What target did OTGateway accept? | <prefix>/settings/heating/target |
50 °C |
| What setpoint did OTGateway calculate? | <prefix>/state/master/heating/setpoint_temp |
50 °C |
| Does the Slave device report that heating is active? | <prefix>/state/slave/heating/active |
true |
| Does the Slave device report a flame? | <prefix>/state/slave/flame |
true |
| What is the measured flow temperature? | <prefix>/sensors/heating_temp/value |
46.5 °C |
If the target changes while the burner stays idle, you can compare the heating request from OTGateway in
state/master/heating/enabled with the activity the Slave device reports in state/slave/heating/active. Further details are in
heating mode and circuit limits. The flow temperature reading is current when the sensor is connected: connected must be true.
Subscribe to <prefix>/sensors/heating_temp/+ to
read the heating flow sensor's value and connection status. Its
value is one measurement. <prefix>/state/master/heating/current_temp is
the average of connected sensors assigned the heating-temperature purpose.
Use <prefix>/sensors/+/connected to see which named sensors are reporting.
mosquitto_sub -h broker.domain -v -t 'otgateway_abcdef/sensors/heating_temp/+'A new sensor can be configured in the web interface. For example, select
Manual via MQTT/API, name the sensor Indoor probe, enable it and choose its purpose.
Temperature exposes a generic reading. Indoor temperature includes it in the indoor temperature that
OTGateway uses for heating.
For programmatic sensor creation, see the REST API example.
Subscribe in one terminal to receive the accepted reading and sensor connection status.
mosquitto_sub -h broker.domain -v \
-t 'otgateway_abcdef/sensors/indoor_probe/value' \
-t 'otgateway_abcdef/sensors/indoor_probe/connected'Send a reading from another terminal. With metric units selected, this supplies 21.5 °C.
mosquitto_pub -h broker.domain -t 'otgateway_abcdef/sensors/indoor_probe/value/set' -m '21.5'Once processed, the command sets value to 21.5 and connected to true. If the reading does not update, check that the sensor is enabled, uses the MANUAL type and has the slug indoor_probe.
Important
Send a reading more often than every 10 minutes. Repeating the same value keeps the MANUAL sensor connected.
Migration from firmware that published aggregate JSON is covered in the MQTT migration instructions.