Repository navigation
Flow Examples
Examples · Flow cards · Supported apps
This page includes a live BLL example and community workflows that combine
BLL variables with other apps. A companion app's ability to send a tag to
BLL does not mean all its text fields support {[ ... ]} coding.
- First variables, devices and Flow
- Save JSON sensor readings
- Report timer states
- Keep decimal formatting in HTTP text
This example was created and tested in English on HP2023 with BLL v4.3.0 Development. It demonstrates four variable types, the three BLL devices, and a regular Flow that updates a count and status when the Trigger device is pressed.
Create these variables in BLL app settings:
| Name | Type | Initial value |
|---|---|---|
Wiki Example Status |
String | Watering complete |
Wiki Example Count |
Number | 3 |
Wiki Example Enabled |
Boolean | true |
Wiki Example Event |
Trigger | No value; it represents an event |
Pair the devices in the Wiki sub-zone under the Better Logic Library zone:
| Device | Linked variable | Configuration |
|---|---|---|
| BitFlip | Wiki Example Enabled |
The tile starts on (true). |
| NumSlide | Wiki Example Count |
Minimum 0, maximum 10, step 1. |
| Trigger | Wiki Example Event |
Pressing the device executes the trigger variable. |

Live device tiles: BitFlip is on, alongside NumSlide and Trigger. The NumSlide range is configured from 0 to 10 in steps of 1.
Create and save a regular Flow in My Flows > Better Logic Library > Wiki:
-
When: Better Logic Library —
Wiki Example Eventis set. -
Then: Increment
Wiki Example Countby1. -
Then: Set
Wiki Example StatustoThe trigger button was pressed. - Press the Trigger device in the
Wikizone.

Live Flow: setting the trigger increments the number variable before setting the status variable.
After one press, the count changes from 3 to 4, the status changes to
The trigger button was pressed, and the trigger variable's last-set time
updates. Wiki Example Enabled remains true. To repeat the test, restore
the count to 3 and the status to Watering complete, then press the device
again. The app settings list and complete variable details are shown in
Variables.
Actual Homey card examples, saved but disabled. They have not been run; follow this page for the full setup and connections.
In this MQTT walkthrough, a JSON Handler card extracts several fields and BLL saves the numeric result tags:
- Trigger the Flow when your MQTT app receives the relevant message.
- Pass the received JSON text to JSON Handler's reading action.
- Configure numeric paths such as
$.CO2,$.IAQand$.GASres. - Set the corresponding BLL number variables from the resulting number tags.
The linked forum example starts with a sample tag rather than a live MQTT trigger. For example, an adapted payload is:
{"CO2":913,"IAQ":84.54,"GASres":1937}The follow-up correction is important: use a card that reads/selects JSON properties, not one that sets properties inside a JSON document. The latter constructs JSON; it does not extract sensor values.
Verify actual payload names and types, handle missing/invalid readings, and test against a sample message first. Connect a receipt-timestamp action if you also want freshness checks.
Actual Homey card examples, saved but disabled. They have not been run; follow this page for the full setup and connections.
This timer-status example combines JSON Handler's loop, Chronograph's running-state condition, a BLL text accumulator and Simple (Sys) LOG:
The steps are:
- Clear a BLL text variable used for this report.
- Start a wait-until-complete loop over a JSON array of timer names.
- Within the loop, check whether the timer named by the current item is running.
- Append its name and
trueorfalseto the report, followed by a line break. - After the loop completes, send the accumulated report to the log.
The original uses Shift+Enter to insert line breaks after the state text. An adapted input list could be:
["HallTimer","KitchenTimer","GardenTimer"]Adding another name to the list does not require duplicating the check cards. Use sequential iteration when updating a shared accumulator, and prevent overlapping report runs from clearing or overwriting each other's text. Decide how to report a missing timer rather than silently treating an error as a valid stopped state.
Actual Homey card examples, saved but disabled. They have not been run; follow this page for the full setup and connections.
A heating-controller question
requires values such as 24.50, including the trailing zero.
The confirmed advice
is to keep the formatted result as text, either in a text variable
or a temporary formatted tag.
- Read the numeric input.
- Format it with two decimals and the separators expected by the recipient.
- Pass the text result to the HTTP card without converting it back to a number.
See fixed decimals and spreadsheet separators for expressions and the No Grouping option. The transport app only needs to accept the resulting text; it need not decode BLL coding.
Use a harmless test endpoint first and keep credentials out of shared
examples. For a JSON request, "24.50" and 24.50 have different types:
match the recipient's schema rather than forcing everything to text.
Support development - If Better Logic Library is useful to you, you can support its
continued development through GitHub Sponsors,
Patreon,
PayPal, or
bunq.
Thank you!