Repository navigation
Choosing A Rotor And Stator
- A stator loop is one full electrical period: one sine wave of the RX coils around the board.
- A rotor lobe is one copper sector on the rotor. The rotor must have as many lobes as the stator has loops (a custom rotor with another count gets a warning). Lobe can also mean half an RX period (see the Glossary).
- The receiver IC reports the angle within one electrical period. With N loops, that period covers 360°/N of mechanical rotation.
| Loops / Lobes | Unique Range | Encoding Type | Extra Resolution From The Coil | Typical Use |
|---|---|---|---|---|
| 1 | 360° | True absolute over the full turn | None (reference) | Absolute joint angle, steering, knobs, output shafts |
| 2 | 180° | Absolute within half a turn | ×2 (+1 bit) | Mechanisms with less than 180° of travel |
| 3 | 120° | Absolute within a third of a turn | ×3 (+1.6 bits) | Limited-travel joints |
| 4 | 90° | Absolute within a quarter turn | ×4 (+2 bits) | Motor commutation for 4 pole-pair motors |
| 8 | 45° | Absolute within 45°, turns counted | ×8 (+3 bits) | Motor commutation and speed control |
| 16 | 22.5° | Absolute within 22.5°, turns counted | ×16 (+4 bits) | High-resolution motor encoders |
Absolute 0–360° Encoding. Use 1 loop. The output is unique over the whole turn from power-up.
Higher Resolution. Use more loops. Each loop repeats the full electrical range, so the resolution per mechanical degree rises by the number of loops. The position is then unique only within one period, and the turn count must be tracked from a homing or index position.
Motor Commutation. Match the loop count to the motor's pole-pair count, so that each electrical period of the sensor lines up with one electrical period of the motor.
Absolute And High Resolution Together. Combine a 1-loop track with a multi-loop track (coarse / fine). The
Dual Coil Set Generator builds exactly this: a coarse inner set (1 loop by
default) and a fine outer set (16 loops by default) on one stator, each read by its own receiver IC, and one rotor disc
with a ring for each set. The coarse angle says which period of the fine track the rotor is in, and the fine track gives
the resolution. This works as long as the coarse angle error stays below half a fine period: 180 / LOOPS of the fine
set mechanical degrees (±11.25° for 16 loops, ±5.625° for 32). Keep the coarse rotor ring away from the fine RX band, or it adds an
error once per turn that no fine-track calibration removes (see
Rotor Features - Dual Coil Set Generator).
| Previous | Next |
|---|---|
| TX Profiles | Stator Features |
Code: PolyForm Noncommercial 1.0.0 · Web Tool: PolyForm Strict 1.0.0 · Docs and images: CC BY-NC-SA 4.0 · Output of the tool and commercial use: 0.2 % commercial terms or written permission (License) · Repository
Start Here
Working Principle / Mathematics - Generator
Design Guide - Single Coil Set Generator
Design Guide - Dual Coil Set Generator
- Stator Features
- Rotor Features
- Board Features
- Dual Layout
- Silkscreen
- Quick Guide To Parameters Selections
Reference
- Parameter Reference Single Coil Set Generator
- Parameter Reference Dual Coil Set Generator
- Checks, Errors And Warnings
- Electrical Estimate
- Suggestive Analysis And Optimization
- Project Output Organization
- Output Pictures
- KiCad Compatibility
- Regression Testing
Research And Community