Skip to content

Suggestive Analysis And Optimization

github-actions[bot] edited this page Nov 10, 2026 · 10 revisions

26. Suggestive Analysis And Optimization

Note

Under construction. The analyser and optimizer are not part of the main branch. They live on the analyser_and_optimizer branch and are still being built, so what is described here may change.

The analyser and optimizer are optional. They never change a board or a parameter file.

  • AnalyzeCoil builds the stator and rotor in memory and simulates both receiver coils while the rotor turns. It reports the signal, offset, SIN/COS match, harmonics and angle error, for the nominal design and for a tolerance window of air gap, rotor eccentricity, tilt and etching.
  • True-3D Copper Model. Each coil is modelled from its real copper, layer by layer, using Biot–Savart. It agrees with exact Biot–Savart within 2–3.5 % rms.
  • Rotor Eddy-Current Model. Each copper lobe is treated as a thin conductor carrying its own eddy current, so copper edges and copper over the TX are judged physically.
  • OptimizeCoil searches the RX profile, sub-coils, split, rotor metal fraction and rotor outer edge, and ranks the results by the worst angle error over the tolerance window. It prints the parameter lines to change.

Example. The optimizer was run on a 1-loop stator (bore radius 18 mm, outer radius 32 mm) with OptimizeCoil.py with ECCENTRICITY_MM and TILT_DEG set to 0 (air gap and metal fraction tolerances only, a much faster run). It suggested two sub-coils split by 50° and rotor copper that ends just over the outermost TX turn:

Design Worst-Case Angle Error (Air Gap 1 ± 0.2 mm) Relative Signal RX Voltage (6–11 Vpp TX)
Start: 1 sub-coil, equal_area profile 0.66° electrical 1.00 106–194 mVpp
Suggested: 2 sub-coils at 50°, copper overhang −0.25 mm 0.18° electrical 1.79 189–346 mVpp

Note

The numbers in this example were made with the earlier, coarser chord defaults. The predicted angle error depends on the chord count (for example 0.777° at 160 chords per loop against 0.456° at 1024 in one test), so older optimizer rankings are superseded. Re-run the optimizer with the current defaults before trusting old numbers.

Analysis 1: Optimizer Comparison

Analysis 1. The starting design, the optimizer's suggestion, and their angle error over one turn at the nominal air gap. Model results only.

Sinusoidal Coil Generator logo, click to see it spin

Previous Next
Electrical Estimate Project Output Organization