Skip to content
Tom-Bom-badil edited this page Sep 15, 2026 · 76 revisions

SAMSON TROVIS controllers

Samson Trovis 557x Heating Controllers
(and compatible models from Yados, Sauter, Pewo ...)

Note

english Note as of 09/2026:
After being online and growing for several years,
this Repo and its Wiki are currently undergoing a major revision.
You can expect broken links and moved files until the revision is finished.


english Hinweis, Stand 09/2026:
Nachdem dieses Wiki viele Jahre online war und gewachsen ist,
unterliegt es nun einer gründlichen Überarbeitung.
Mit kaputten Links / verschobenen Dateien ist bis zum Ende der Überarbeitung zu rechnen.


deutsch DE   Wozu dieses Projekt? english EN   What is this project about?
Diese Reise begann 2014 auf der Suche nach tiefergehenden Informationen über meinen Pewo PCR06 Heizungsregler. Mein Ziel war das Lesen und Visualisieren der eingestellten Parameter sowie der Betriebsdaten in meinem damaligen Python-basierten SmartHomeNG Home Automation System.


Es stellte sich heraus, dass der PCR06 identisch zur Samson TROVIS 5575 ist - dass es sich um eine ganze Produktfamilie handelt, und dass die Regler als OEM auch noch unter anderen Namen auf dem Markt sind (Pewo, Yados, Sauter).

Heute wird die Software für meine mittlerweile getauschte 5576-0003 entwickelt und auf meiner „Bastelstrecke“ (5578 + 5579) sowohl mit Modbus/TCP als auch Modbus/RTU getestet. Sie ist auf allen Modellen mit Modbus-Schnittstelle lauffähig (5571, 5573(-1),5575, 5576, 5578(-E)).

Hinweis: Soll eine 5575 / ein Pewo PCR-06 angebunden werden, bitte diesen Hinweis beachten. Danke an @edomi-fan, der nach mehreren Jahren das Geheimnis dieses Modells endlich lüften konnte!

Dieses Wiki soll weiterhin der Zusammenfassung von allen möglichen Informationen zu den verschiedenen Modellen sowie ihrer Anbindung dienen und gleichzeitig den Einstieg in das Thema „Modbus“ erleichtern (siehe Kapitel im Anhang).

Das Wiki wurde über viele Jahre (bis ca. Mitte 2026) ausschließlich auf Deutsch geführt. Da im Rahmen von Umstellungen im Home Assistant Core (modbus-connection) Trovis aber als erstes Referenz- und Beispielprojekt verwendet wurde, kamen einige internationale Teilnehmer hinzu. Entsprechend wird es jetzt zumindest teilweise zweisprachig geführt.

Screenshot 1

SmartHomeNG / SmartVISU, 2017

This journey began in 2014 when I was looking for more detailed information about my Pewo PCR06 heating controller. My goal was to read and visualize its configuration parameters and operating data in my Python-based SmartHomeNG home automation system I was using at the time.


It turned out that the Pewo PCR06 is identical to the Samson TROVIS 5575, that it belongs to an entire family of heating controllers, and that these controllers are also sold as OEM products under other brand names (Pewo, Yados, Sauter).

Today I develop the software for my TROVIS 5576-0003, which has replaced the original controller, and is tested on my dev setup (5578 + 5579) using both Modbus/TCP and Modbus/RTU. It runs on all models equipped with a Modbus interface (5571, 5573(-1),5575, 5576, 5578(-E)).

Note: If you want to connect a 5575 / Pewo PCR-06, please read this note. Many thanks to @edomi-fan, who finally managed to uncover the secret of this model after several years of tinkering!

This wiki is intended to also serve as a collection of information about the various controller models and how to connect them, while also providing an introduction to Modbus for readers who are new to the subject (see the chapters in the appendix).

For many years (until around mid-2026), this wiki was maintained exclusively in German. However, when TROVIS was used as the first reference and example project for changes in Home Assistant Core (modbus-connection), several international contributors joined the project. As a result, the wiki is now maintained at least partly in both German and English.

Screenshot 2

HomeAssistant (YAML-config), 2025



deutsch DE   Wie funktioniert das? english EN   How does it work?

Grundsätzlich verfügen die Regler -je nach Modell- über verschiedene Schnittstellen:

  • einen Gerätebus (vermutlich RS485 mit HART®-Protokoll) zur Kommunikation mit einem Leitsystem,
  • einen Zählerbus (M-Bus) für einen oder mehrere Wärmemengenzähler,
  • einen Systembus (RS232 mit dem Protokoll Modbus RTU; teilweise auch per SPI an der Frontbuchse verfügbar), z. B. zur Kommunikation mit TROVIS-VIEW.

In diesem Projekt wird der Systembus verwendet, um über Modbus sogenannte Register (16-Bit-Speicherplätze, engl. Parameters → PA1..n) und Schalter (Einzelbits, engl. Coils → CO1..n) mit den vorhandenen Einstellungen und Betriebswerten in regelmäßigen Intervallen auszulesen.

Das Projekt besteht demzufolge aus zwei Teilen:

  • Der hardwareseitigen Anbindung mit einem speziell gefertigten seriellen Kabel und dem richtigen Setup der Verbindung PC ↔ Regler (USB, LAN, WLAN – je nach verwendetem Adapter).
  • Der softwareseitigen Anbindung an verschiedene Heimautomationssysteme. Hierfür wurde auch eine neutrale Bibliothek geschaffen, welche die Bedienung der TROVIS in Standard-Python-Funktionen übersetzt und von den einzelnen Systemen verwendet werden kann, ohne das berühmte Rad jedes Mal neu erfinden zu müssen.

Screenshot 2 Making a new connection cable

Depending on the model, the controllers provide several different interfaces:

  • a device bus (likely RS485 using the HART® protocol) for communication with a higher-level control system,
  • a meter bus (M-Bus) for one or more heat meters,
  • a system bus (RS232 using the Modbus RTU protocol; on some models also available via SPI at the front connector), for example for communication with TROVIS-VIEW.

In this project, the system bus is used to periodically read the controller's current settings and operating values via Modbus. These are stored in so-called registers (16-bit memory locations, referred to as Parameters → PA1..n) and coils (individual bits → CO1..n).

Accordingly, the project consists of two main parts:

  • The hardware connection, using a specially made serial cable and the appropriate setup for the connection between the PC and the controller (USB, LAN or Wi-Fi, depending on the adapter being used).
  • The software integration with various home automation systems. For this purpose, a system-independent library was also created that translates interaction with the TROVIS controller into standard Python functions. This library can then be used by the individual systems without having to reinvent the wheel each time.

Screenshot 2
Ready to start!



deutsch DE   Was wird benötigt, und was kostet das? english EN   What's required, and how much is it?

Um eine Kommunikation mit dem Regler aufzubauen, wird Folgendes benötigt:

  • Ein USB-, LAN- oder Wi-Fi-Adapter (ich selbst verwende den USR-TCP232-T2, da ich von dieser Firma bereits einen RS485-Adapter an meiner Helios KWL im Einsatz habe). Weiterhin habe ich auch erfolgreich einen USB-FTDI-Adapter ausprobiert, wie er auch für das Flashen von ESP-Modulen verwendet wird.

    🔥 Update: Mittlerweile verwende ich den USR-K7, der den 232-T2 nach mehreren Jahren Betrieb abgelöst hat (siehe Ende der Bauanleitung). Dadurch wird keine virtuelle Software-Schnittstelle mehr benötigt.
    Auch ist die Anbindung von ESPs über die Jahre einfacher geworden; hierfür gibt es in den Diskussionen einige Beispiele.
  • Ein altes LAN- oder RJ45-Telefonkabel mit 8 Pins für die seitliche Buchse am Gerät (= serielles Kabel Marke „Eigenbau“). Wer sauber und schick arbeiten möchte, besorgt sich noch eine passende Buchsenleiste (weiblich/female) für den Anschluss des Kabels an den Adapter sowie etwas Schrumpfschlauch für die Isolierung der einzelnen Pins nach dem Löten.
  • Eine virtuelle Software-Schnittstelle, über die der Computer (z. B. Raspi, NAS oder PC) mit dem Regler kommuniziert. Diese kann entweder mit Bordmitteln oder als kostenloser Download realisiert werden.

    🔥 Update: Bei den Anbindungen mit den neuen Adaptern (mit 🔥 rechts gekennzeichnet) ist keine virtuelle Schnittstelle mehr notwendig, da sie per Modbus/TCP arbeiten. Virtuelle Schnittstellen werden somit nur noch bei „klassischen“ Anbindungen per serieller Direktverbindung oder USB benötigt.
  • Als Werkzeug wird ein Lötkolben mit dem üblichen Lötzubehör benötigt (zum Anlöten des Kabels an die Buchsenleiste oder direkt an den TTL-Adapter).

    🔥 Update: Mittlerweile gibt es auch RJ45-Kabel mit Schraubterminals günstig zu kaufen; somit sind nun auch lötfreie Verbindungen möglich.

Wenn man irgendwo also noch ein altes Netzwerk- oder Telefonkabel herumliegen hat, liegen die Kosten mit einem günstigen USB-Adapter unter 10 Euro; mit einem LAN-Adapter etwas höher bei ca. 20–40 Euro (je nach verwendetem Adapter).

Screenshot 2
ser2net Adapters

To establish communication with the controller, the following components are required:

  • A USB, LAN or Wi-Fi adapter (I personally use the USR-TCP232-T2, as I already had good experience with an RS485 adapter from the same manufacturer on my Helios ventilation system). I have also successfully tested a standard USB FTDI adapter, of the type commonly used for flashing ESP modules.

    🔥 Update: Meanwhile I am using the USR-K7, which replaced the 232-T2 after several years of operation (see the end of the assembly instructions). With this adapter, a virtual software interface is no longer required.
    In addition, connecting ESP devices has also become easier over the years; several examples can be found in the discussions.
  • An old LAN cable or 8-pin RJ45 telephone cable to connect the adapter to the socket on the side of the controller (= a homemade serial cable). For a cleaner and more professional setup, you may also want to use a suitable female pin header for connecting the cable to the adapter, as well as some heat-shrink tubing to insulate the individual pins after soldering.
  • A virtual serial interface through which the computer (e.g. Raspberry Pi, NAS or PC) communicates with the controller. This can either be provided using built-in operating-system functionality or free software.

    🔥 Update: For connections using the newer adapters (marked with a 🔥 in the menu on the right), a virtual interface is no longer required because these adapters are accessed directly via Modbus/TCP. It is therefore only still needed for “classic” setups using a direct serial connection, USB or Modbus RTU adapters.
  • A soldering iron and the usual soldering equipment are required as tools (to solder the cable to the female pin header or directly to the TTL adapter).

    🔥 Update: Meanwhile, inexpensive RJ45 cables with screw terminals have also become available, enabling solderless connections.

So, if you already have an old network or telephone cable lying around, the total cost can be less than €10 when using an inexpensive USB adapter. With a LAN adapter, the cost is somewhat higher at around €20–40, depending on the adapter used.

Screenshot 2
Also possible: Solder-free installation.

german Wiki - Start english


english Bauanleitungen

Schritt 1 - Kabel

Schritt 2 - Adapter

Schritt 3 - Schnittstelle

Schritt 4 - Regler

Schritt 5 - Erster Test

🔥 Update: Weitere Adapter


english Home Assistant Integration

🚀 Getting started

🔌 Using the integration

🧑‍💻 Technical reference

🔢 Related projects


english SmartHomeNG Plugin


german2 Anhang: Info-Sammlung

Clone this wiki locally