Repository navigation
Functional and Structural MRI Data Following Transcranial Static Magnetic Stimulation Over the Motor Cortex
This dataset provides multiecho resting-state fMRI, diffusion-weighted imaging (DWI), and high-resolution structural T1-weighted MRI data from right-handed healthy participants.
Each subject participated in two experimental sessions involving real and sham transcranial static-magnetic-field stimulation (tSMS) over the right motor cortex (hand area).
The study employs a double-blind randomized crossover design, enabling direct comparison between stimulation conditions.
This resource facilitates investigation into tSMS-induced changes in functional connectivity, microstructural organization, and motor network dynamics, combining structural, diffusion, and multiecho functional MRI.
License
Creative Commons Attribution 4.0 International (CC BY 4.0)
Citation
Caballero-Insaurriaga, J., Pineda-Pardo, J. Á., & Foffani, G. (2025).
Functional and Structural Magnetic Resonance Imaging Data Following Transcranial Static Magnetic Stimulation Over the Motor Cortex (1.0.1) [Data set]. Zenodo.
https://doi.org/10.5281/zenodo.15224957
Source
https://doi.org/10.5281/zenodo.15224957
Contact: jaime.caballero@unican.es
Institutions: Universidad de Cantabria, Hospital Nacional de Parapléjicos, Universidad Autónoma de Madrid
Funding: Supported by institutional research programs in non-invasive brain stimulation (NIBS)
Dataset Information
| Category | Details |
|---|---|
| Subjects | Right-handed healthy adults |
| Design | Randomized double-blind crossover (real vs sham tSMS) |
| Target Site | Right motor cortex (hand area) |
| Modalities | Multiecho resting-state fMRI, diffusion-weighted imaging (DWI), high-resolution T1-weighted MRI |
| Conditions | 30-minute real tSMS and sham tSMS sessions |
| Sessions | Two sessions per subject, separated by one week, same weekday and time |
| Data Format | NIfTI (.nii/.nii.gz) |
| Correction Notice (v1.0.1) | Fixed scaling of phase images (now in −π..π range) |
Experimental Details
This dataset includes multiecho resting-state fMRI, Diffusion-Weighted Imaging, and high-resolution structural T1-weighted MRI data acquired from right-handed healthy participants, immediately following 30-minute real and sham tSMS over the right motor cortex (hand region).
Each participant underwent two separate sessions, one with real and one with sham stimulation, performed on separate days but at the same time of day and weekday.
The order of stimulation was randomized and double-blind, ensuring balanced and unbiased comparisons.
Demographics and Experimental Information
Additional participant details, including demographics (e.g., exact age) and condition-specific experimental notes, are available upon reasonable request to the authors.
Conversion to NIfTI
All data were converted from native DICOM to NIfTI format using dcm2niix.
File naming corrections and supplemental JSON metadata fields were added using a custom Python script to ensure consistency and completeness.
Defacing
High-resolution T1-weighted anatomical scans were defaced using FSL’s fsl_deface command.
While this tool reliably removes identifiable facial features, it can slightly reduce the apparent size of the frontal pole (see [Bischoff-Grethe et al., NeuroImage, 2021, doi:10.1016/j.neuroimage.2021.117845]).
To mitigate this, the defacing mask was expanded prior to defacing by combining (binary union) the default mask with a dilated brain mask (7×7×7 voxel kernel).
The brain mask was extracted using FreeSurfer’s mri_synthstrip, and dilation and combination were performed using fslmaths, ensuring full brain coverage for all subjects.
Scaling of Phase Images
Both multiecho fMRI and DWI were acquired using the CMRR multiband-accelerated EPI pulse sequences (no multiband factor applied due to coil constraints).
Magnitude and phase reconstructions were exported for each dataset.
Native phase images were scaled in the −4096..4094 integer range (as discussed in CMRR Issue #238) and verified by the authors.
Using FSL tools, these were losslessly rescaled to radians (−π..π) by adjusting scl_slope and scl_inter fields in the NIfTI header without altering data type or stored voxel values.
Rescaling formula:
[
\text{phase (radians)} = \frac{x}{4096} \times \pi
]
Software Versions
| Component | Version / Build |
|---|---|
| CMRR Multiband EPI | R016–R017 |
| dcm2niix | v1.0.20230411 (GCC 12.2.0, Linux x86-64) |
| Python | 3.8.17 |
| FSL | 6.0.6.4 |
| FreeSurfer | 7.3.2 |
File Information
| File | Description | Size | Checksum |
|---|---|---|---|
| tSMS_M1R_MRI.zip | MRI data (multi-echo fMRI, DWI, and T1w) for both real and sham stimulation sessions | 35.2 GB | md5:2d9f8b9c1ca647dac96619442cffa321 |
Keywords
MRI • fMRI • Multi-Echo • Resting-State • Diffusion MRI • DWI • Motor Cortex • tSMS • Transcranial Static Magnetic Field • Non-Invasive Brain Stimulation • NIBS • CMRR • Phase Correction