Repository navigation
In Vivo Human Whole-Brain Connectom Diffusion MRI Dataset at 760 µm Isotropic Resolution
This dataset provides a whole-brain in vivo diffusion MRI (dMRI) acquisition at 760 µm isotropic resolution, sampled at 1,260 q-space points across nine 2-hour sessions on a single healthy adult subject.
It demonstrates the limits of ultra-high-resolution diffusion imaging achievable with advanced Connectom-class hardware, optimized acquisition protocols, and reconstruction pipelines.
The dataset enables exploration of fine-scale in vivo brain structures, fiber microarchitecture, and serves as a benchmark for developing high-resolution modeling, sub-sampling, denoising, and reconstruction algorithms.
License
Creative Commons Zero v1.0 Universal (CC0-1.0) — public domain dedication
Citation
Wang, F., Dong, Z., Tian, Q., Liao, C., Fan, Q., Hoge, W. S., Keil, B., Polimeni, J. R., Wald, L. L., Huang, S. Y., & Setsompop, K. (2021).
In vivo human whole-brain Connectom diffusion MRI dataset at 760 µm isotropic resolution) [Data set]. Dryad.
https://doi.org/10.5061/dryad.rjdfn2z8g
https://datadryad.org/dataset/doi:10.5061/dryad.nzs7h44q2
Source
https://doi.org/10.5061/dryad.rjdfn2z8g
Contact: kawin@nmr.mgh.harvard.edu
Institutions: Massachusetts General Hospital (MGH) & Harvard Medical School
Supported by: NIH BRAIN Initiative & MGH A.A. Martinos Center for Biomedical Imaging
Related work: 10.5061/dryad.nzs7h44q2
Dataset Information
| Category | Details |
|---|---|
| Subject | Single healthy adult volunteer |
| Scanner | 3 T Connectom MRI system (300 mT/m gradient strength) |
| Coil | Custom-built 64-channel phased-array head coil |
| Resolution | 0.76 mm × 0.76 mm × 0.76 mm isotropic |
| Sessions | 9 sessions × 2 hours = 18 hours total acquisition |
| q-space Sampling | 1,260 directions total |
| Sequence | SNR-efficient diffusion-weighted spin-echo EPI |
| Reconstruction | Parallel imaging with ghost-artifact reduction and SENSE acceleration |
| Stabilization | Personalized motion-robust head stabilizer |
| Additional Data | Submillimeter T1w and T2w anatomical MRI, field maps, and preprocessing code |
| Data Format | NIfTI (.nii.gz) and supporting metadata (.bval, .bvec, JSON) |
Experimental Setup
This dataset was acquired using state-of-the-art Connectom hardware and optimized dMRI sequences to push spatial resolution while maintaining high SNR.
Key elements:
- High gradient strength (300 mT/m) allowing short diffusion times and strong diffusion weighting.
- Custom 64-channel phased-array coil for increased parallel imaging acceleration and sensitivity.
- Advanced ghost reduction algorithms during reconstruction.
- SNR-efficient acquisition design minimizing echo-train blurring.
- Nine separate scanning sessions ensuring full q-space coverage while minimizing motion contamination.
Preprocessing and Code
The dataset includes accompanying preprocessing scripts and documentation for:
- Denoising
- Eddy-current and motion correction
- Gradient-nonlinearity correction
- Signal normalization and registration to T1/T2 anatomy
All reconstruction and preprocessing steps are described in detail within the included README and supplementary code repository.
Purpose
This dataset represents one of the highest-resolution in vivo human dMRI datasets publicly available.
It is intended to support:
- Development and benchmarking of microstructural modeling and tractography algorithms
- Validation of denoising and sub-sampling frameworks
- Studies of fine-scale cortical and subcortical connectivity
Keywords
Diffusion MRI • High Resolution • Connectom Scanner • 760 µm • Human Brain • Microstructure • q-space Sampling • Parallel Imaging • Ghost Reduction • Tractography • Martinos Center • BRAIN Initiative