Reproducibility Dataset Across 10 Imaging Centers
This dataset provides a multi-shell diffusion MRI benchmark collected from three traveling human subjects scanned across ten imaging centers, with tightly controlled acquisition protocols. It is designed to evaluate scanner variability, site effects, and reproducibility in diffusion MRI studies.
Preprocess note
Quality control (QC) analysis identified a significant issue with the b-table data across the majority of the original dataset, which would lead to incorrect diffusion tensor reconstruction results. Specifically, only two scans, sub-3_ses-c02r1 and sub-2_ses-c02r1, were found to have valid b-values (bval) and b-vectors (bvec)
Dataset Overview
- Subjects: 3 (traveling subjects scanned repeatedly)
- Sites: 10 imaging centers
- Design: Same subjects scanned across multiple sites
- Purpose:
- Quantify inter-site variability
- Evaluate reproducibility of diffusion MRI metrics
- Benchmark harmonization and processing pipelines
Imaging Protocol
-
Diffusion MRI:
- Multi-shell acquisition
- Identical protocol across all sites
-
Structural MRI:
- T1-weighted imaging
- Consistent acquisition parameters
-
Key feature:
- Strict control of scanner settings and protocols
- Minimizes confounds unrelated to site/scanner differences
Preprocessing Pipeline
The dataset includes a standardized preprocessing workflow implemented on:
- System: CentOS 6.7
Software Dependencies
- FSL 5.0.11
- FreeSurfer v1.379.2.73
- MRtrix3 0.3.15
Processing Steps
Diffusion Processing
- Denoising (MRtrix3)
- Gibbs ringing removal (unring)
- Distortion correction
- TOPUP (susceptibility distortion)
- EDDY (motion and eddy current correction)
Structural & Skull Processing
- Skull stripping applied to both:
- T1-weighted images
- Diffusion images
Data Organization
-
Scripts included:
Prep_diffusion.sh→ diffusion preprocessing pipelinePrep_face_removal.sh→ skull strippingexample.sh→ full pipeline execution
-
Designed as a reproducible and automated workflow
Data Privacy
- All personal identifiers removed
- Acquisition timestamps anonymized:
- Synthetic timestamps used
- Only relative timing preserved
Usage Agreement
- License: CC BY 4.0
- https://creativecommons.org/licenses/by/4.0/
Users are free to:
- Share and adapt the data
- Use for research and publication
With requirement:
- Proper attribution
Scientific Value
This dataset is particularly useful for:
- Multi-site harmonization studies
- Scanner variability analysis
- Diffusion metric reliability evaluation
- Method validation (e.g., tractography, connectomics)
- Benchmarking preprocessing pipelines