A WeeWX driver for weather hardware that pushes its readings to a server rather than waiting to be polled.
- Installation — install, point the hardware at it, start
- Protocols — what each protocol sends, and how they are told apart
- Configuration — every option, with worked examples
- Diagnostics — one command that answers most questions
- Web interface — see what a station sends, and place a field without a restart
- Field map — from raw field to database column
- Hardware — every device, and what it takes to reach it
- Sensors — every field this driver knows, by sensor
- Unknown fields — what happens to a field the catalog misses
- Stations — setting one up, roles, and column ownership
- Database columns — which columns a station needs, and how to add them
- Reporting a new sensor — exactly what to send
- Troubleshooting — symptoms and what they mean
- Keeping strangers out — path, token, addresses, TLS
- Development — layout, tests, rebuilding a catalog
Six protocols:
| Protocol | Hardware |
|---|---|
| Ecowitt | GW1000, GW1100, GW1200, GW2000, GW3000, HP2551, HP2561, WS3800, WS3900, WS3910, WN1980, Froggit, Misol |
| Weather Underground | Fine Offset Observer, Ambient WS-1000, Sainlogic, any console set to Wunderground, Meteobridge, most weather software |
| Ambient Weather | WS-2902, WS-5000, WS-1965 and the rest of the range |
| WeatherFlow | Tempest, AIR, SKY |
| Acurite | smartHUB, Access |
| LaCrosse | LW301, LW302 |
They share one port. Which protocol sent an upload is determined from its content, and each receives the response its own firmware expects.
Approximately 900 raw field names are mapped. On the Ecowitt side this covers the WH31, WN34, WN35, WH40, WH41, WH43, WH45, WH46, WH51, WH52, WH55, WH57, WH65, WH68, WN20, WN38, WS68, WS80, WS85, WS90 and LDS01; on the Ambient side the whole range, including the AQIN air quality module and the relays; and everything the consoles report about themselves.
The station posts or broadcasts its readings. The driver determines which protocol was used, converts each raw field name into a WeeWX field using that protocol's catalog, writes the packet, and reports to WeeWX which unit each new field is in.
Fields the catalog does not cover are examined rather than dropped. A field that continues a known series is placed automatically; a field that is merely recognisable by name is reported. Fields whose placement the hardware does not settle — a WN34 that might be in a raised bed or in a pool, an Acurite tower that might be anywhere — wait until you say where they go.
With more than one station, three further rules apply: exactly one station is the main station, a column belongs to whichever station fills it first, and a column that already holds readings is not written into without confirmation. See Stations.
- Installation
- Hardware
- Web interface
- Stations
- Several stations
- Hosted hardware
- Sensors this driver asks
- Database columns
- Configuration
- Diagnostics
- Troubleshooting
- Keeping strangers out
- Reporting a new sensor
- Acurite
- Davis AirLink
- Ambient
- Ecowitt
- Ecowitt gateway API
- Ambient Weather (ambientweather.net)
- Home Assistant
- Lacrosse
- PurpleAir
- rtl_433
- Weatherflow
- Wunderground