Six of them. What each one sends, how the driver tells them apart, and what is peculiar about each.

If your station works and the readings look right, you do not need this page. It is for deciding what to buy, working out why a field is missing, or adding a protocol.

The six

Name Hardware Transport Units Names the station with
ecowitt Ecowitt gateways and consoles, Froggit, Misol POST, any path imperial PASSKEY
wunderground Fine Offset Observer, Sainlogic, Meteobridge, any console set to Wunderground GET, fixed path imperial or metric ID and PASSWORD
ambient Ambient Weather, Custom upload in awnet POST or GET, any path imperial PASSKEY
weatherflow Tempest, AIR, SKY UDP broadcast, port 50222 metric hub serial number
acurite smartHUB, Access POST, fixed path imperial bridge id
lacrosse LW301, LW302 POST, any path metric MAC address

How an upload is recognised

Not by which port it came to. Every posting protocol shares one port, and the driver looks at what is in the upload.

Each protocol says how sure it is that an upload is its own, and the surest wins. In order of how much that settles:

The path. A device that speaks Weather Underground cannot be told to post anywhere but /weatherstation/updateweatherstation.php. So that path is nearly conclusive. Nearly, because an Acurite bridge posts there too.

A name only one protocol uses. mt is Acurite's and nobody else's. mac with a two-character id is LaCrosse's. stationtype=AMBWeather... is Ambient's. PASSKEY with any other station type is Ecowitt's.

Credentials. ID and PASSWORD together are Weather Underground's, which matters behind a reverse proxy that rewrites the path.

An upload that matches none of them is refused rather than read with whichever catalog happened to be first. The same name means different things in different catalogs, and UV is the example: an index in one dialect, microwatts per square centimetre in another, forty times apart. If you know what your hardware is, name it:

[UltimatePush]
    protocols = ecowitt

With exactly one protocol configured there is nothing left to guess, and an upload with nothing in it but readings is read as that one.

Protocols and dialects

They are different questions, and the driver asks both.

A protocol is an exchange: a path, an answer, a way of naming the station.

A dialect is a catalog: what the names mean and what units they arrive in.

Weather Underground has two dialects on one endpoint. Fine Offset consoles under one firmware send tempf, baromin and dailyrainin in Fahrenheit and inches; under another they send outtemp, relbaro and dailyrain in Celsius and millimetres. Same path, same credentials, same protocol. The driver decides per upload, on names alone, so no reading has to be plausible for the answer to be right.

Ecowitt

The default. Set Customized in the WSView app, protocol Ecowitt, and choose your own path.

It wants JSON back:

{"errcode":"0","errmsg":"ok"}

An upload it cannot acknowledge is retried and eventually given up on, which is why the answer is exact rather than an empty 200.

The catalog has 532 fields and is generated from ecowittcustom. See Sensors.

Weather Underground

The oldest of them, and the only one where the hardware can present a shared secret. PASSWORD is in every upload, so it can be checked:

[UltimatePush]
    password = whatever-you-set-in-the-console

Everything else here has to be kept out with a path nobody can guess, or with allowed_hosts. See Keeping strangers out.

The path is fixed in the firmware, so path = /something/secret and Weather Underground hardware cannot both be had. .php, .asp and no extension at all are accepted, because firmwares have shipped all three.

RapidFire, realtime=1&rtfreq=2.5, is read like any other upload. It arrives up to every two and a half seconds; WeeWX handles that, and the archive record is unaffected.

Three things about this protocol are worth knowing, and all three come from real uploads rather than from the specification:

-9999 means "no reading". Fine Offset firmwares send it for a sensor that has nothing to report. Read as a number it is nine thousand degrees below freezing, and it would go into the archive and into every average computed from it.

baromin means two things. Sea-level pressure on almost every firmware, station pressure on WH2600GEN_V2.2.5 and WH2650A_V1.2.1. Both of those say so in softwaretype, so the driver moves the field for them and says so once in the log. Your own field_map_extensions outranks that.

UV in the metric dialect is not the index. It is the raw irradiance in microwatts per square centimetre, which is why captured uploads carry values like 919. It goes to uvradiation in watts per square metre, not to UV.

The metric dialect and the wind

One thing about that dialect cannot be read off a payload: whether the wind arrives in kilometres per hour or in metres per second. The two differ by 3.6, both are plausible for the numbers these consoles send, and the firmware does not say.

The default follows weewx-interceptor, which has been pointed at this hardware for a decade: kilometres per hour. If your console disagrees:

[UltimatePush]
    metric_wind = mps

The packet then becomes weewx.METRICWX, where rain is in millimetres and no rain conversion is needed either.

Ambient Weather

Descended from the same Fine Offset design as Ecowitt's, and it shows: a PASSKEY built from the MAC address, imperial units, the same POST of an urlencoded form.

What differs is the vocabulary. Ambient says soilhum1 where Ecowitt says soilmoisture1, battout where Ecowitt says wh65batt, lightning_day where Ecowitt says lightning_num. It also has relay1 to relay10 and the AQIN indoor air module, which Ecowitt has no equivalent of.

Read with the Ecowitt catalog an Ambient upload does not fail. The temperature and the wind arrive and the soil probes, the batteries and the lightning sensor are dropped. The station type is what separates them, and Ambient consoles always send theirs.

WeatherFlow

The odd one out, in three ways.

It broadcasts. A hub sends JSON to the whole local network on UDP 50222, whether or not anybody is listening. Nothing is configured on the hub and nothing is answered, so there is nothing to keep strangers out with beyond the network itself. Use allowed_hosts if that matters.

Because it needs a socket of its own, it is not in protocols = auto. Name it:

[UltimatePush]
    protocols = ecowitt, weatherflow

The readings are positional. An observation is an array, and index 7 of obs_st is the air temperature because it is. A mapping that is off by one puts the humidity in the pressure column and looks entirely plausible, which is why the layouts are tested against WeatherFlow's own examples.

Its rain is already a difference. Every other protocol here sends running counters. A hub sends the millimetres since its last report, which is what WeeWX means by rain. Differencing it again with StdDelta would record almost nothing.

Eight message types are read: obs_st, obs_air, obs_sky, rapid_wind, evt_strike, evt_precip, device_status and hub_status. rapid_wind arrives every three seconds and becomes a loop packet like any other.

An AIR and a SKY on one hub are one station with two sensors, so the hub's serial number is what names the station, not the device's.

Acurite

A smartHUB or an Access posts to Chaney's own servers and cannot be told otherwise. Reading it means answering for hubapi.myacurite.com on your own network: a DNS entry, or a rule on the router. That is a decision about your network rather than about this driver, and it is in Hardware.

One request per sensor. A frame says what kind of sensor it is in mt and which one in sensor, then carries three or four readings. A station with a 5-in-1 and three towers sends four requests every eighteen seconds, each with tempf in it, each meaning something different.

So the 5-in-1 is the station and keeps the plain names, and everything else arrives named after the sensor that sent it:

tower00002719_tempf
tower00002719_humidity

Which wall that tower is on is not in the payload. Decide, then paste:

[UltimatePush]
    [[field_map_extensions]]
        tower00002719_tempf = extraTemp1
        tower00002719_humidity = extraHumid1

The name stays the same across restarts, because the bridge keeps its sensor numbers.

The bridge puts its own barometer in every frame it forwards, whatever sent it, so that one is not qualified. It is station pressure whatever the name suggests: the bridge does not know its own altitude, and WeeWX derives barometer from this and the altitude in weewx.conf.

Not read: the Chaney format. Bridges before July 2016 send their own shape, where the readings are hex strings and the pressure has to be computed from seven calibration constants. A bridge updates itself from Chaney on first contact, so a station still on it has been offline for nine years.

LaCrosse

An LW301 or LW302, likewise pointed here by a DNS entry.

Two-letter names, one request per sensor, and a ch saying which channel a sensor is on. Channel 1 is the station. Channels two and up go to extraTemp and extraHumid, and where they hang is yours to say.

The gateway sends Celsius, metres per second and millibars, and then sends its rain in inches. That one conversion is done on the way in.

Nine of its parameters have never had their meaning established: p, or, gw, av, htr, cz, ttr, rro, pv, lb, ac, ptr and the uv that is not uvh. They are kept out of the database, because a column of numbers nobody can label is worse than no column, and written to the report so that somebody with the hardware can work them out.

Not read: the GW1000U. It does not send name and value pairs at all. It registers with the server, is told its serial number, its ping interval and its display brightness, and then exchanges binary frames. That is a different protocol, not a dialect of this one.

Adding one

A protocol is a small class and a catalog. bin/user/ultimatepush/protocols/ has six worked examples, and Development has the walkthrough.

What is needed:

  • how to recognise an upload as yours, in claims
  • what the fields are called, in a catalog
  • what the hardware wants to read back, if anything
  • which field names the station
  • which rain counter has to be differenced, or None if the protocol sends rain

A captured payload in tests/fixtures and a test against it are the rest.