PowerTrace

Connecting physical infrastructure signals to application observability — so you know exactly why your AI workload broke.


The Problem

When an AI training job slows down or crashes, two separate teams start investigating simultaneously.

The infrastructure team is staring at power dashboards — PDU feeds, server thermals, UPS status. The platform/SRE team is staring at APM dashboards — traces, error rates, GPU utilization. Neither team can see what the other sees.

The result: engineers spend hours manually reconstructing what happened after the damage is already done. A power fluctuation that caused a GPU to thermal throttle, which caused a training job to lose a checkpoint, gets discovered in a post-mortem — not in real time.

For AI companies running large GPU clusters, this is not a minor inconvenience. A single interrupted training run can cost $50,000 or more.


What PowerTrace Does

PowerTrace is an OpenTelemetry-native correlation engine that connects physical infrastructure signals to your application observability stack.

It produces a unified causal timeline like this:

INCIDENT DETECTED — llama-inference-api (confidence: 89%)
Window: 14:32:01 – 14:33:48 (107 seconds)

CAUSAL CHAIN
  14:32:01  [CRITICAL] PDU voltage sag          PDU-B-rack-14
  14:32:02  [CRITICAL] PSU failover             server-rack-14-node-3
  14:32:03  [MEDIUM]   CPU power cap applied    server-rack-14-node-3
  14:32:04  [HIGH]     GPU thermal throttle     GPU-0
  14:32:07  [HIGH]     GPU power cap applied    GPU-0
  14:32:11  [IMPACT]   Trace degradation        llama-inference-api
              P99: 530ms → 2,100ms (+296%)
              Error rate: 0.1% → 4.3%
              Throughput: 140 rps → 61 rps (-56%)

IMPACT
  Duration: 107 seconds
  Est. cost: $0.35  (--gpu-rate 11.57 × 107s)
  Root cause: PDU-B voltage sag on rack-14

This is the correlation that currently takes hours to reconstruct manually.


Why This Doesn't Exist Yet

The DCIM (data center infrastructure management) world and the observability world have always been separate industries with separate buyers, separate tools, and separate vocabularies.

The OTel ecosystem has receivers for Kafka, Redis, MySQL, and dozens of software systems. It has nothing for physical power infrastructure.

AI changed the urgency. Traditional cloud workloads have stable, predictable power profiles. AI training jobs do not — they are massive, spiky, and catastrophically expensive to lose mid-run.


Who This Is For

On-Prem and Colocation AI Teams

You run GPU clusters in your own facility or a colo. You have physical access to PDUs, server BMCs, and network infrastructure. PowerTrace ingests those signals directly via SNMP and Redfish and connects them to your existing OTel traces.

Cloud-Based AI Companies

You're on AWS, GCP, or Azure. You have no visibility into the physical data center — the CSP owns that. But you're not completely blind.

Signals accessible from inside your cloud instance:

  • NVML — per-GPU power draw, thermal throttle state, power cap events. Accessible from inside any cloud GPU instance (p4d, A100 on GCP) without physical access.
  • RAPL — Intel's CPU power capping interface, accessible via /sys/class/powercap/ on many cloud instances.
  • AWS Health Events API — Amazon surfaces underlying hardware events that affect your instance: host degradation, scheduled retirement, network connectivity issues. These are physical events in disguise.
  • Azure Resource Health / GCP Instance Health — equivalent signals for other CSPs.

The gap for cloud customers: these signals exist but nobody is ingesting them into OTel and correlating them with traces automatically. PowerTrace does.

Colocation Providers

When a power event causes a tenant's workload to degrade, you spend hours proving the cause was or wasn't on your end. PowerTrace gives you the evidence in real time.


Architecture

Signal Sources                    PowerTrace                  Your Backend
──────────────                    ──────────                  ────────────
PDU SNMP          ─────────────►
Redfish (BMC)     ─────────────►  Correlation    ──────────►  Grafana
NVML (GPU)        ─────────────►  Engine         ──────────►  Datadog
RAPL (CPU)        ─────────────►                 ──────────►  Honeycomb
AWS Health Events ─────────────►                 ──────────►  Any OTel backend
                                       │
                              Topology Map
                         (device → service mapping)

PowerTrace takes three inputs:

Input What it contains
events.json Infrastructure events (GPU throttle, PDU voltage, AWS Health, etc.)
traces.json OTel trace metrics and spans (P99, error rate, throughput)
topology.json Mapping of physical devices to logical services

And produces a ranked causal timeline with confidence scores.


Supported Signal Sources

Source Protocol On-Prem Cloud
PDU power events SNMP
Server BMC Redfish
PoE switch SNMP
UPS SNMP
GPU telemetry NVML
CPU power capping RAPL
AWS Health Events HTTP API
Azure Resource Health HTTP API
GCP Instance Health HTTP API

Quickstart

git clone https://github.com/hitkall/powertrace
cd powertrace
pip install -r requirements.txt

python correlate.py \
  --events sample_data/events.json \
  --traces sample_data/traces.json \
  --topology sample_data/topology.json

Sample data is included so you can run a full correlation demo without any real infrastructure.


Configuration

python correlate.py \
  --events events.json \
  --traces traces.json \
  --topology topology.json \
  --window 5 \        # correlation time window in seconds (default: 5)
  --lag 60 \          # max correlation lag in seconds (default: 60)
  --baseline 600 \    # baseline lookback window in seconds (default: 600)
  --confidence 0.6 \  # minimum confidence threshold to report (default: 0.6)
  --output timeline \ # output format: timeline | json | markdown
  --gpu-rate 3.50     # optional: GPU cost in USD/hr — enables cost impact estimate

--gpu-rate is intentionally optional. Without it, Est. cost shows null rather than printing a confident-looking wrong number. GPU pricing varies enormously (on-demand vs reserved vs spot vs owned hardware), so PowerTrace requires you to supply the rate explicitly. Pass the on-demand hourly price for your instance type — e.g. --gpu-rate 3.50 for a p3.2xlarge or --gpu-rate 11.57 for a p4d.24xlarge.


How the Correlation Works

  1. Parses and validates all three input files using Pydantic
  2. Builds a topology index mapping physical device IDs to logical service names
  3. Calculates a rolling baseline per service (P99, error rate, throughput)
  4. Detects anomaly windows where metrics deviate more than 2x from baseline
  5. For each anomaly window, looks back up to --lag seconds for preceding infrastructure events
  6. Filters events to those whose device maps to the affected service via the topology index
  7. Ranks events by severity, time proximity, and physical layer priority
  8. Scores confidence: penalizes time gaps, rewards topology matches and severity alignment
  9. Emits incidents above the confidence threshold with full causal chains and impact metrics

Known Limitations

  • Timestamp skew: Physical devices may have clock drift up to several seconds. Confidence scores account for this but cannot eliminate it. Use NTP-synchronized devices where possible.
  • Topology accuracy: Correlations are only as accurate as your topology map. Stale mappings produce incorrect causal chains.
  • Sampling gaps: If OTel traces are sampled at low rates, short power events may fall between sampled spans. Increase trace sampling rate for GPU-heavy services.
  • Baseline drift: Services with naturally high or variable latency require a longer baseline window to produce reliable anomaly detection.
  • Cloud physical layer: For cloud deployments, PowerTrace cannot see below the hypervisor. CSP-surfaced health events are the closest available signal.

Roadmap

  • Correlation CLI with simulated inputs
  • AWS Health Events receiver (boto3 — Python)
  • CloudWatch metrics receiver (boto3 — Python)
  • Grafana dashboard (unified physical + trace timeline, Prometheus + Tempo)
  • NVML receiver (pynvml — Python)
  • OTel Collector receiver for PDU SNMP (Go)
  • OTel Collector receiver for Redfish (Go)
  • Predictive alerting (power budget trending before threshold breach)
  • Proposed OTel semantic convention for physical infrastructure attributes

Design Partners

If you run AI infrastructure — on-prem, in a colo, or on cloud GPU instances — and you want early access or want to collaborate, reach out.

Specifically looking for teams who have experienced unexplained training job degradation and want to understand whether physical infrastructure was the cause.

LinkedIn | kalluruhitesh3@gmail.com


Contributing

PowerTrace is in early development. Contributions welcome — especially:

  • Additional signal source receivers
  • Topology auto-discovery integrations
  • OTel semantic convention proposals for physical infrastructure

See CONTRIBUTING.md for setup instructions.


Related Work


License

Apache 2.0