Bridge and PWM
Converter Units share the same bridge-model, control-period, PWM-register and ADC configuration.
bridge:
type: three_phase_bridge
model: pwm_averaging
on_resistance: 0.0
parallel_capacitance: 0.0| Field | Values | Default | Purpose |
|---|---|---|---|
type |
half_bridge, full_bridge, three_phase_bridge
|
selected by Unit type | electrical topology |
model |
switching, pwm_averaging, averaging
|
pwm_averaging |
simulation form |
upper_controlled, lower_controlled
|
switches | 1 | controlled rows of a half bridge or full bridge |
reverse_port |
switch | 0 | half-bridge power-port direction |
external_terminal |
midpoint, lower_rail
|
midpoint |
exposed half-bridge terminal |
on_resistance |
ohm per conducting device | 0 | device voltage drop and loss |
parallel_capacitance |
F | 0 | capacitance across the bridge power port |
bridge.model |
Electrical representation | Controller execution | Use for |
|---|---|---|---|
switching |
exact carrier-comparison switch states | sampled ADC, computation and PWM loads | ripple, harmonics and commutation |
pwm_averaging |
held active duty between register loads | same sampled periods and updates as switching | sampled control without carrier ripple |
averaging |
continuous controlled voltage | continuous controller equations | control-envelope and long-duration studies |
Each converter Unit selects its model independently.
| Configuration | Result |
|---|---|
| both values zero | ideal bridge; no additional state |
nonzero on_resistance
|
finite conducting-path voltage drop and loss |
nonzero parallel_capacitance
|
adds continuous state bridge.u_C
|
nonzero parallel_capacitance with zero resistance |
rejected |
A half-bridge or three-phase conducting leg uses one device resistance; a full-bridge current path
uses two. Use switching to resolve individual capacitor charging and commutation pulses.
ctrl:
period: 50e-6
offset: 0.0
computation: 1e-6
pwm:
f_sw: 20000.0
update: single
sync: asynchronous
pattern_sync: interval
dead_time: 0.0
dead_time_compensation: false
meas:
period: 25e-6
offset: 0.0
window: 50e-6| Setting | Default | Constraint | Effect |
|---|---|---|---|
ctrl.period |
1 / pwm.f_sw |
whole multiple of half a carrier period | controller interrupt period |
ctrl.offset |
PWM load-clock position | within one control period | controller interrupt position |
ctrl.computation |
1 us in sampled models | 0 <= computation < period |
command eligibility delay |
pwm.f_sw |
required for sampled control | positive Hz | carrier and default control frequency |
pwm.update |
single |
single or double
|
active-register load rate |
pwm.carrier_phase |
0 | carrier periods | asynchronous carrier position at t = 0
|
pwm.sync |
asynchronous |
asynchronous or synchronous
|
carrier clock source |
pwm.pattern_sync |
interval |
interval or pulse
|
waveform replacement rule |
pwm.dead_time |
0 | seconds, less than half a switching period | complementary-device turn-on delay |
pwm.dead_time_compensation |
false |
Boolean | add current-polarity duty-ratio feedforward |
meas.period |
ctrl.period; otherwise simulation.output.period
|
divides ctrl.period when sampled |
ADC conversion period |
meas.offset |
aligned with controller interrupts | within one ADC period | ADC conversion position |
meas.window |
ctrl.period |
no longer than ctrl.period
|
averaging window |
At one timestamp, all due ADC conversions run before any Unit applies a newly computed command.
ctrl:
period: 50e-6
loops:
CurrentLoop: {period: 50e-6}
DCVoltageControl: {period: 500e-6}- A loop period defaults to
ctrl.period. - A loop period must be an integer multiple of
ctrl.period. - Loop keys are registered class names and graph-node names.
- Repeated classes use qualified names such as
Observer[voltage]. -
{}, a bare key and YAMLnullare equivalent empty parameter mappings.
Scalar feedback loops calculate
command = feedforward + PI(startup * reference - measured).
| Measurement | Modulation command | Phase command | Frequency command |
|---|---|---|---|
| power | PowerControl |
PhasePowerControl |
FrequencyPowerControl |
| voltage | VoltageControl |
PhaseVoltageControl |
FrequencyVoltageControl |
| current | CurrentControl |
PhaseCurrentControl |
FrequencyCurrentControl |
The control graph selects the measurement and command. Optional <measurement>_filter settings
filter the selected feedback.
meas:
average: [voltage, current, power]
window: 50e-6
period: 12.5e-6
offset: 0.0Channels in meas.average return the window mean; other channels are sampled instantaneously. If
ADC conversion and control coincide, conversion runs first. An offset conversion is held until the
next controller interrupt. For an oscillating port, average power directly rather than
multiplying separately averaged voltage and current.
meas:
sources: {power: load.power}
rms: {current: 200e-6}meas.sources accepts public outputs ending in .voltage, .current or .power. meas.rms maps
a channel to a window in seconds. Results use <unit>.meas.<channel>_rms; configured means use
<unit>.meas.<channel>_mean.
| PWM load instant | Applied value |
|---|---|
after ctrl.computation completes |
newly computed shadow value |
| at the interrupt or during computation | previous completed shadow value |
consistently less than computation after the interrupt |
one additional control-period delay |
Only the newest completed value is retained in the shadow register.
pwm.update |
Active-register loads |
|---|---|
single |
carrier valleys |
double |
carrier valleys and peaks |
Three-phase PWM uses pwm.method: spwm or svpwm; pwm.modulation_limit defaults to 1.
Synchronous PWM requires an integer ratio pwm.f_sw / base.f0.
pwm.pattern_sync |
Update rule |
|---|---|
interval |
replace the waveform at the register load |
pulse |
finish an active pulse before starting the new pattern |
pulse may insert a zero gap of up to one pattern period. Averaged models do not construct
pulse-preservation state.
Dead time is applied to the leg sequence after modulation, so carrier and phase-shift modulation
share the same current-directed diode-clamping rule. The pole-current direction is sampled at each
register load and held for that interval. pwm_averaging applies the cycle average; legs held at
duty 0 or 1 do not commutate. A half bridge with one controlled device has no complementary
turn-on, so it has no dead time or compensation. Ideal averaging warns and ignores both settings.
For duty-ratio modulation, compensation adds dead_time * f_sw * sign(pole_current) using the ADC
sample at the control interrupt; clipping at 0 or 1 limits the correction.
Phase-shift patterns have no independent leg duty-ratio commands, so this compensation is not
accepted for ctrl.type: phase_shift.
| Criterion | Evaluation boundary |
|---|---|
| instantaneous overcurrent | switching or held-bridge edges |
| voltage and DC-link voltage | controller or measurement period |
| RMS current | configured RMS window |
| frequency and ROCOF | controller or measurement period |
A Unit without sampled control uses meas.period for measurement, RMS and held protection
criteria. A trip blocks the bridge and disconnects the DC source.
With bridge.model: averaging, controller and plant states are integrated continuously.
| Setting or feature | Behavior |
|---|---|
ADC interrupt and meas.offset
|
not used |
ctrl.period, ctrl.offset, ctrl.computation
|
not used for controller execution |
| carrier and PWM register loads | not used |
pwm.dead_time, pwm.dead_time_compensation
|
ignored |
meas.period |
protection and RMS period |
| loop implementation | must provide a continuous-time equation |
| Command | Bridge model | Solver preset |
|---|---|---|
--switching |
switching for every Unit |
fixed-step RK4 |
--pwm-averaging |
pwm_averaging for every Unit |
fixed-step RK4 |
--averaging |
averaging for every Unit |
adaptive DP45 |
Explicit --set options take priority over a preset.