Skip to content

Solvers

github-actions[bot] edited this page Oct 2, 2026 · 2 revisions

Solvers

PESLite integrates every interval up to the next exact boundary: an event, output point, sampled hardware instant or requested end time. Solver stages never cross a model-changing boundary.

Fixed-step solvers

simulation:
  solver:
    type: fixed
    method: rk4
    dt: 25e-6

Available fixed methods are euler, heun and rk4. dt is the maximum step, not a demand that every interval have exactly that length. When an exact boundary falls inside a step, PESLite divides the interval into equal shorter steps ending precisely at the boundary.

RK4 is the normal starting point for switching and pwm_averaging. Reduce dt until important outputs and event responses are insensitive to further reduction.

Adaptive solvers

simulation:
  solver:
    type: adaptive
    method: DP45
    rtol: 1e-3
    atol: 1e-9
    max_step: .inf

DP45 is PESLite's built-in Dormand-Prince 4(5) implementation. SciPy methods RK23, RK45, DOP853, Radau, BDF and LSODA are also available in Python simulations.

rtol controls error relative to the current state scale, while atol supplies an absolute floor near zero. Smaller tolerances generally increase accepted steps and RHS evaluations. max_step limits how far the solver may advance even when the error estimate would permit more.

Adaptive DP45 is the normal starting point for ideal averaging, where no PWM time grid forces small intervals. Sampled modes are supported with adaptive integration, but the solver still stops at every controller, register and switching boundary, which can remove much of the adaptive-speed benefit.

Command presets

Command Bridge Solver
--switching exact switching fixed RK4
--pwm-averaging PWM-period averaging fixed RK4
--averaging ideal averaging adaptive DP45

These flags are configuration presets. Explicit --set values for solver type or method take priority, so one file can be reused while deliberately testing another combination.

Multirate integration

Named subsystems can use a step relative to the fixed system step. This supports fast substeps and slow windows while keeping event boundaries exact. Multirate schedules require simulation.solver.type: fixed; see Multirate Simulation.

Event-aware solver contract

A solver is called only for the interval presented by Simulation. Before a model-changing event, an optional settle(t, y) hook can finish deferred work such as a multirate window. After a set event, an optional parameters_changed() hook can refresh cached parameter-dependent data.

This contract also applies to user solvers. A simple user solver only needs the normal callable interface; the hooks are required only when it defers state or caches mutable parameters.

Energy checks and diagnostics

Before a run, simulation.energy_check controls validation of component energy declarations:

  • warn: report structural or balance problems and continue;
  • strict: reject a problematic model;
  • off: skip the check.

During a run, simulation.solver.phs_check_step sets the number of output snapshots between energy audits. It defaults to 1000 and is intended as an internal performance/diagnostic control rather than a primary model setting.

--ph-report prints the assembled port-Hamiltonian structure without running. Solver counts, rejected adaptive steps and multirate interface indicators are written to summary.json.

Selection guidance

Study Starting choice
Switching edges and ripple fixed RK4 with a converged dt
Sampled control without carrier ripple fixed RK4, PWM-period averaging
Continuous averaged dynamics adaptive DP45
Stiff continuous dynamics a suitable SciPy implicit method, verified against a reference
Strongly separated subsystem time scales fixed multirate, after a single-rate baseline

Always establish convergence for the quantities used in the conclusion. Output density is not an integration-accuracy setting.