Notifications
You must be signed in to change notification settings - Fork 2
Extending PESLite
PESLite uses registries and small typed protocols for custom control loops, circuit elements and
events. Installed modules under peslite/addons/ and project-local modules under a PESaddons/
directory beside a simulation file share the same package search paths and registries. Types kept
elsewhere can still be imported and registered explicitly before loading a simulation file that
names them.
The root examples/ directory contains simulation files only. Bundled Python implementations live
under peslite.addons, while additional test-only implementations exercise the same interfaces in
the test suite.
Project-local controllers, components and functions can live beside a simulation rather than in the installed package. Their exact search rules and their relationship to the output directory are defined once in Project Workspace.
The bundled custom-pll-example demonstrates this layout: its .pes file remains in examples/,
while peslite.addons.control.voltage_adaptive_pll contains the executable custom loop. It
uses a filtered measured-voltage magnitude and grid-frequency state, then joins the same GFL graph
as the built-in current and DC-voltage loops.
The bundled cable-gfl-example similarly keeps its case in examples/, while
peslite.addons.components.cable implements its own distributed R-L/G-C state equations. It is a
two-terminal custom element rather than a renamed built-in branch: both terminal currents are
positive into the cable, and its internal inductor currents and capacitor voltages are ordinary
restartable PESLite states.
Register a loop class with register_loop_type:
from dataclasses import dataclass
from peslite.addons.control import SyncLaw, register_loop_type
@register_loop_type
class LaggedSync(SyncLaw):
@dataclass(frozen=True, kw_only=True)
class Params:
period: float
k_p_pu: float
tau: float
type: str = "lagged_sync"
type = "lagged_sync"
state_names = {"theta": "theta", "p_f_pu": "p_f"}
def __init__(self, cfg, unit, startup):
super().__init__(cfg, unit, startup)
self.p_f = 0.0
def _sample(self, period, p_pu, q_pu, v_mag_pu, v_dc_pu,
p_ref_pu, q_ref_pu, v_ref_pu, i_dq):
self.p_f += period / self.cfg.tau * (p_pu - self.p_f)
self.omega = self.w0 + self.cfg.k_p_pu * (p_ref_pu - self.p_f)
self.theta += period * self.omega
self.v_mag = v_ref_pu
def _flow(self, p_pu, q_pu, v_mag_pu, v_dc_pu,
p_ref_pu, q_ref_pu, v_ref_pu, i_dq):
self.omega = self.w0 + self.cfg.k_p_pu * (p_ref_pu - self.p_f)
self.v_mag = v_ref_pu
return self.omega, (p_pu - self.p_f) / self.cfg.tauThe nested frozen Params dataclass defines the file schema and defaults. A module stored under
peslite/addons/control/ is discovered automatically; the registered name is then available at
units.<u>.ctrl.loops.<loop>.type exactly like a built-in loop.
A specialized loop may expose separate sampled and continuous-flow laws. When its dynamics can be
built from the standard blocks, define one equation() instead: the graph supplies its inputs,
collects the registered states and derivatives, and selects sampled or continuous block
implementations during construction. Typed ports still validate all connections before running.
The essential pattern is:
from peslite.addons.control import Filter, Integrator, PI
def __init__(self, cfg, unit, startup):
super().__init__(cfg, unit, startup)
self.angle = self.state_block(
"theta", Integrator(self.block_period, initial=0.0)
)
self.regulator = self.state_block(
"integral_pu", PI(kp, ki, self.block_period)
)
self.feedback = self.state_block(
"feedback_pu",
Filter(num=(1.0,), den=(tau, 1.0), period=self.block_period),
)
def equation(self, signal, omega, reference, feedforward):
measured = self.feedback(signal)
command = self.regulator(reference, measured, feedforward)
theta = self.angle(omega)
return command, thetaLoop.block_period is the configured loop period for sampled bridge models and None for ideal
averaging. Construction therefore selects a sampled or continuous implementation once; the call
itself has no mode branch. Filter follows the Transfer Fcn coefficient convention: numerator and
denominator coefficients are in descending powers of s, and the transfer function must be
proper. Its sampled implementation, and the sampled integral branch of Integrator and PI, use
the trapezoidal (Tustin) method. The complete bundled example is
peslite.addons.control.voltage_adaptive_pll.
An element class registered by register_element_type owns:
- a frozen
Paramsdataclass including itstypeandbusorbusNfields; -
subsystems()for its physical model objects; -
connections()for its internal and auxiliary signal wiring; -
terminals()binding each configured bus to an electricalTerminal; - optional
signals()returning namespaced scalar or complex values forplant.csv; - optional
connect(),disconnect()orretune()behavior.
from peslite.addons.components import Element, Terminal, register_element_type
@register_element_type
class MyElement(Element):
type = "my_element"
# Params and assembly methods...The file can then use:
elements:
device: {type: my_element, bus: pcc}Modules under peslite/addons/components/ are discovered automatically. Built-in and add-on
elements follow the same registry mechanism. Public names are namespaced by the element instance,
so two instances do not share state paths.
An electrical Terminal names a subsystem voltage input and current output once. Its direction is
+1 when positive current enters the subsystem and -1 when it leaves. A one-terminal element
uses bus and returns one binding; a multi-terminal element uses bus1, bus2, and so on and
returns one binding per terminal. System assembly converts these declarations to direct model
connections, so terminal metadata adds no work to the integration loop.
Every entry returned by signals() follows the same output path. Complex values become three
phase columns with _a, _b and _c suffixes, while scalar values retain their declared name;
custom signal names do not require recorder-specific code.
The cable add-on is a complete multi-terminal reference implementation:
elements:
cable1:
type: cable
bus1: grid_bus
bus2: pcc
length_km: 5.0
r_per_km: 0.05
l_per_km: 0.4e-3
c_per_km: 0.2e-6
g_per_km: 1.0e-8
sections: 2Its per-kilometre parameters are SI values. sections changes the spatial discretisation and
therefore the state layout, so it is fixed when the simulation is assembled.
Register an Event subclass with register_event_type. Its Params dataclass contains at least
type and t, and apply(event, system, t) performs the action:
from dataclasses import dataclass
from peslite.assembly import Event, register_event_type
@register_event_type
class Marker(Event):
@dataclass(frozen=True, kw_only=True)
class Params:
t: float
type: str = "marker"
type = "marker"
@staticmethod
def apply(event, system, t):
passCustom events receive the same exact-boundary scheduling as built-in events.
A user solver is a callable receiving (rhs, t0, t1, y0) and returning SolverStep. It owns its
RHS count and must finish exactly at t1. Optional hooks are:
-
settle(t, y): finish deferred work before a model-changing event; -
parameters_changed(): refresh cached data after asetevent; - named state methods when the solver has continuation state.
Pass the object to Simulation(params, solver=solver). A simple single-rate solver does not need
the optional hooks.
UniteType builds a controller from a parameter tree, PWM method and output stage. A replacement
controller satisfies the Controller protocol; a replacement modulator satisfies Modulator and
returns a SwitchingSequence. The unit checks these protocols at assembly time.
Keep protection decisions in the unit hardware layer. Controller output contains commands and startup status; it should not directly open breakers or mutate the system.
- Validate custom scalar relationships in
Params.__post_init__by raisingConfigError. - Declare stable public state names so restart and CSV output remain deterministic.
- Preserve named state when rebuilding a retuned object.
- Keep structural changes out of
setevents; expose only parameters that can be applied safely. - Use SI inside physical components and explicit per-unit conversion at controller boundaries.
Pure numerical custom subsystems with a fixed state/inp/out layout have an automatic C++
fallback. During export, PESLite symbolically traces their scalar set_outputs() and rhs()
equations, specialises configuration branches and fixed loops, and emits static C++. The cable
add-on is exported through this fallback; it does not carry a second handwritten C++ equation.
Built-in modules still use dedicated lowering, which covers their complete event and timing
semantics and gives the generator more opportunities for deliberate optimisation.
The fallback does not embed Python in the binary. Dynamic Python behavior outside a pure numerical equation—such as I/O, reflection, changing the state layout or an unsupported library call—is rejected. Custom loops, events and modulators that alter discrete scheduling still need explicit backend support rather than being approximated.